A system of dosimetric calculations

Slides:



Advertisements
Similar presentations
Chapter 4 Radiation Dosimeters
Advertisements

RADIATION PROTECTION IN RADIOTHERAPY Part 10: Optimization of protection in External Beam Radiotherapy PRACTICAL EXERCISE IAEA Post Graduate Educational.
F. Foppiano, M.G. Pia, M. Piergentili Medical Linac IEEE NSS, October 2004, Rome, Italy
Pencil-Beam Redefinition Algorithm Robert Boyd, Ph.D.
Energy deposition and neutron background studies for a low energy proton therapy facility Roxana Rata*, Roger Barlow* * International Institute for Accelerator.
Photon Beam Monitor-Unit Calculations
Measurement of Absorbed Dose (6)
Sec.3 Practical application 临床处方剂量的计算.  What we should calculate?  Time or mu required to delivery proper dose for tumor  Dose distribution at the.
Factors affecting the X-Ray output
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Electron Beams: Physical Principles and Dosimetry
Chapter 5 Central Axis Depth Dose Calculations
Beam Therapy Equipment 3 Patient Treatment and Accessories.
Ch .4 Clinical Radiation Generators
Electron Beams: Physical Principles and Dosimetry
Quality Control Rad T 110.
Dose Distribution and Scatter Analysis
Linac Beam.
Dosimetric evaluation of a new design MOSFET detector Per H. Halvorsen* & Stephanie Parker University of North Carolina.
Copyright © 2010 by Mosby, Inc., an affiliate of Elsevier Inc.
TWO FIELD BREAST PLAN VS. OPTIMIZED CONFORMAL BREAST PLAN: COMPARISON OF PLAN PARAMETERS Authors: Borko Basarić, Ozren Čudić, Milan Teodorović, Borislava.
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
Radiographic Dosimetry
Radiation Protection in Radiotherapy
In vivo dosimetry Eirik Malinen Eva Stabell Bergstrand Dag Rune Olsen.
Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.
Fundamental Dosimetry Quantities and Concepts: Review Introduction to Medical Physics III: Therapy Steve Kirsner, MS Department of Radiation Physics.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Araki F. Ikegami T. and Ishidoya T.
Part VIII:Medical Exposures in Radiotherapy Lecture 6: Determination of dose to the patient in Radiotherapy II IAEA Post Graduate Educational Course on.
بسم الله الرحمن الرحيم. Simulation of Photon Beam Interaction with the ZUBAL Head Phantom Presented by: Mostafa Hossni El-Soubki Plan-UNC-Image plotter.
Part VIII:Medical Exposures in Radiotherapy
F. Foppiano, M.G. Pia, M. Piergentili
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
Calibration of an Ionisation Chamber for use in Megavoltage Dosimetry
TLD POSTAL DOSE QUALITY AUDIT FOR 6MV AND 15MV PHOTON BEAMS IN RADIOTHERAPY CLINICAL PRACTICE Sonja Petkovska 1, Margarita Ginovska 2, Hristina Spasevska.
The Radiotherapy Application NMT 232 L 8 1. Radiotherapy Generators Kilovoltage X-rays are generally used in the treatment of skin cancers and superficial.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
1 A protocol for the determination of absorbed dose from high energy photon and electron beams AAPM TG-21 Protocol (Med Phys 10: , 1983) 和信治癌中心醫院.
Commissioning of a commercial treatment planning system for IMAT and Dose Painting treatment delivery. G. Pittomvils 1,,L. Paelinck 1, F. Crop 2, W. De.
Monitor Unit Calculations for External Photon and Electron Beams
Rapid Arc Treatment Verification: post evaluation on Delta-4 and proposal of a new verification protocol G. Pittomvils 1,,L. Paelinck 1, T. Boterberg 1,
Date of download: 6/23/2016 Copyright © 2016 SPIE. All rights reserved. (a) Relative positions of the linear accelerator (LINAC) gantry, treatment region,
MCS overview in radiation therapy
Adapting A Clinical Medical Accelerator For Primary Standard Dosimetry
AAPM TG-51 Protocol (Med Phys 26: , 1999)
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
Qing Liang, PhD Medical Physicist Mercy Health System, Janesville, WI
Chapter 5 Central Axis Depth Dose Calculations. 2 Definition of Beam Geometry The accurate delivery of a radiation dose to patient depends on the precise.
SIMULATION CHECK LIST IMAGING PROTOCOL.
CHAPTER 3 DOSE DETERMINATION FOR EXTERNAL BEAMS
The physics of Radiation Therapy, pp
Electron Beam Therapy.
Khan, The Physics of Radiation Therapy, Ch7
Absolute Dose Measurement
Chapter-9 Dose Distribution And Scatter Analysis
HANDOUT; MEDICAL PHYSICS 30 (6),
David Sutton or Colin Martin But Borrowed from Jerry Williams
Development and characterization of the Detectorized Phantom for research in the field of spatial fractionated radiation therapy. D. Ramazanov, V. Pugatch,
Template Matching Can Accurately Track Tumor Evaluation of Dose Calculation of RayStation Planning System in Heterogeneous Media Huijun Xu, Byongyong Yi,
Arghya Chattaraj, T. Palani Selvam, D. Datta
Chapter 14 Electron Beam Therapy (1)
Ch 10. A System of Dosimetric Calculations
Chapter 8 (Part 1) Measurement of Absorbed Dose
Relationship between dosimetric leaf gap and dose calculation errors for high definition multi-leaf collimators in radiotherapy  Jinkoo Kim, James S.
Ch6 Measurement of Ionizing Radiation
Sheng Yang a, Yen-Wan Hsueh Liu b
Hot and cold spots are common problems associated with planning:
AL305-Physics II Meeting #2 Photon Beam Dosimetry
Principles and Practice of Radiation Therapy
Presentation transcript:

A system of dosimetric calculations 2005/02/21

Percentage depth dose (PDD)

PDD

PDD vs. SSD

Mayneord factor  unsuitable for isocentric techiniques The dependence of PDD on SSD  unsuitable for isocentric techiniques

Tissue Air Ratios (TAR)

The limitations of TAR It’s hard to measure in free space when the beam energy higher than Co-60. As the beam energy increases, the size of the chamber build-up for in-air measurements has to be increased. Karzmark et al.  tissue-phantom ratio (TPR) Holt et al.  tissue-maximum ratio (TMR)

Effective primary dose The effective primary in a phantom may be thought of as the dose at depth minus the phantom scatter. The effective primary dose may be defined as the depth dose excepted in the field when scattering volume is reduced to zero while keeping the collimator opening constant.

Collimator scatter factor (Sc) output factor It may be defined as the ratio of the output in air for a given field to that for a reference field. Sc may be measured with an ion chamber with a build-up cap of a size large enough to provide maximum dose build-up for the given energy beam.

Phantom scatter factor (Sp) It takes into account the change in scatter radiation originating in the phantom at a reference depth as the field size is changed. At the depth of maximum dose may be defined as BSF

Total scatter factor It’s defined as the dose rate a reference depth for a given field size r divided by the dose rate at the same point and depth for the reference field size(10*10 cm). It contains both the collimator and phantom scatter.

Arrangement for measuring Sc and Sc,p

Tissue-Phantom Ratio (TPR) It’s defined as the ratio of the dose at a given point in phantom to the dose at the same point at a fixed reference depth, usually 5 cm. TPR(r)=TPR(0)+SPR(r) The corresponding quantity for the scattered Dose is called the scattered-phantom ratio

The definition of TPR/TMR

Tissue-Maximum Ratio (TMR) TMR is a special case of TPR. It may be defined as the ration of the dose at a given point in phantom to the dose at the same point at the reference depth of maximum dose.

Properties of TMR TMR is independent of SSD FS ↑, TMR ↑ depth ↑, TMR ↓

The area factor It’s the ratio of the dose rate for a given field size to that of a reference field size, usually 10 * 10 cm. The dose rate for a reference field multiplied by the area factor for the treated field gives the dose rate for the treated field. The dose rates may have been measured and tabulated for a large number of field sizes, which eliminates the need for an area factor. The cGy/MU may have been set so that 1 cGy is the same as 1 MU for a reference field, is usually 10 * 10 cm.

Dose-Calculation’s Parameters Prescribed dose SSD: PDD SAD: TAR, TMP, TPR Field size factor (Khan: Sc,p) Dose per Monitor Unit (Dose/MU) Accessory factors ( tray, wedge…etc.)  MU

Techniques in treating patients Fixed source-surface distance technique Fixed source-axis distance technique

Fixed source-surface distance technique

Dose calculation at depth of maximum dose Consider the treatment of a 12 * 12 cm field using a 4-MV photon beam at 100-cm SSD. The Dose/MU for a 10 * 10 cm field is 1. The field size factor for 12 * 12 cm is 1.03. To find the necessary to deliver prescribed Dmax dose:

To deliver 200 cGy at Dmax which for 4 MV is at 1-cm depth, the number of MU would be:

To deliver 200 cGy at 5 cm

Fixed source-axis distance technique

Parallel opposed fields using an isocentric technique A treatment is delivered via equally weighted parallel opposed beams using 4-MV photon beams. The number of MU is found from

To deliver 100 cGy at 12-cm depth The patient is 24 cm in diameter, the SAD is 100 cm, and the fields are 12 * 12 cm. The Dose/MU at Dmax is 1.000 The FSF is 1.030 for 12 * 12 cm The TMR from A-18 at 12-cm depth is 0.716.