Sensistor ISH2000Training

Slides:



Advertisements
Similar presentations
Product Presentation. WHAT IS IT? Product Presentation.
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
DP-IR Detecto-Pak Infrared
Using the MiniRAE 3000.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
XL40D Training. The Clarity Professional XL40D offers our patented Digital Clarity Power that uses digital technology to enhance the volume and clarity.
Personal Surveyor 200 (PS200) Series
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
1 LIFECARE PLV-100 by Bryce Younger. 2 Classification ► Electrically powered  microprocessor controlled ► Volume-control, time cycled ► Rotary drive.
Familiarization and Operation
Clean Air Box Usage & Care CABs RAMs CO Monitors.
DIGITAL LIGHT METER Dr. Lim Jac Fang Occupational Health Doctor Department of Health, Sabah 1994 CT Lutron LX-105 LIGHT METER.
Bmd Crossvent 3.
Produces audio signals to be used as a tool or aid in any audio system Pink or white noise Used to mask or cover unwanted background noise Helps limit.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Gates Professional Development Series Gates Sonic Tension Meter 507C NEW! Measures Tension in BothV-BeltsAnd Synchronous Belts.
1 Light OP 504 ex – Project Presentation Luca Invernizzi Design.
Pentagon Digital Mini Pocket Projector Product Info.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
Nokia Bluetooth Headset BH-108 for Contact Centers
The Headphones1 Trainer Training The Headphones. 2 There are three sets of headphones There are three transmitters Transmitters also act as battery chargers.
Self Guided Tour of TagMate™QC Display Tag DATA Tag Data: PRINT TagMate™QC SETUP Display STATS Tags: START and READ SEND All Data to PC Additional Capabilities.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
NAVIGATOR™ Portable Balances
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Graphic Equalizer Table Top View
Miscellaneous Test Equipment Combustion, Tachometers, Hygrometers The materials included in this compilation are for the use of Dwyer Instruments,
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
BUILDING LOAD NORMAL OPERATION 1. ATS are in normal position connected to utility source 2. All generator set paralleling circuit breaker open.
New Electric Actuators EA Type
1 1.
Sensistor ISh2000 Hydrogen Leak detector
Extrima ex-certified Hydrogen Leak detector
KX-TU329 Loud Voice Amplification
Bluetooth Headset ZM-HPS10BT Sales Guide
System Network Structure
IN SAMPLE PUMP INNOVATION
LED Display Verification of Functionality
LDA Large Display for Analog Inputs
The Relay based Multiplexer
FEEDER PROTECTION UNIT
Peter Dennis – Dover PPM Communications
VLT Diagnostics Click on the button above your Keypad.
Intro and T1 Troubleshooting
Lamp Error reset Method to solve “Lamp Error” problem
Application Operation principle Advantages Highlights Comparison
Call to Fix Canon Pixma MX340 printer Error 5200
Instruction Manual Specifications Features: Dimension:38*16*6 mm
McCrometer Nano Board Test Procedure
Morphological Chart (10/28)
G450 and G460 battery pack maintenance
Laser 3000™ Operating Instructions
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
PHASE IDENTIFICATION UNIT (PIU)
Digital Chart Recorder Operation
Customer Presentation
1/17/2019.
MateCam _1080P WIFI Live Streaming Cam Video Recorder
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
GASMET DX4040 Antti Heikkilä 1.
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Main Unit Establishment
724 Temperature Calibrator
Dräger X-am 5000 / X-am 5600 VIDEO BASIC TRAINING
Nellcor™ Bedside SpO2 Patient Monitoring System, PM100N - Home use
Presentation transcript:

Sensistor ISH2000Training Lennart Larsson 2011-01-21

Sensistor ISH2000 Hydrogen Leak Detector H2000 to ISH2000

Models and Specifications Sensistor ISH2000 Sensistor ISH2000C Sensistor ISH2000P Operating time: 8 hours. Charging time: 6,5 hours. Charger: AC 100-240 V 50/60Hz 24 VDC Current: max 3A AC 100-240 V 50/60Hz All models: Sensitivity (Analysis Mode): 5x10-7 mbarl/s Range: 5x10-7 - 4x10-2 mbarl/s Repeatability: Typ. ± (10% of measured value +3x10-7 mbarl/s)

Display Speaker Control buttons Earphone outlet Probe connector LED LED indikeringar: Grön blinkande, uppvärmning pågar allt ok Grönt fast sken är lika med instrumentet är klart för att användas Rött fast sken tillsammans med Läck i displayen betyder en läcka är detekterad som är högre än den satta läckgränsen Rött blinkande, kolla displayen något är fel kontrollera i användare manualen Display Speaker Control buttons Earphone outlet Probe connector LED

Out and Inputs Printer port Active Probe Control 220 AC Connector ISH2000 ISH2000P ISH2000C 24VDC Connector Printer port Active Probe Control Battery charger input Printer port Printer port Active Probe Control 220 AC Connector

Specification 500C 00C IP 64 10-90% RH ISH2000 3,9 kg ISH2000C 4,0 kg ISH2000P 1,8 kg Bredd: 275mm Höjd: 155mm Djup: 170mm

P50 Hand Probe LED indications: P50 Flex Green blinking: during warming up Green: instrument ready and under leak limit Red: instrument display indicates leak Red flashing: error indication, check user manual Both types of probes are fitted with dual LED’s that can be switched on to illuminate the area the probe tip is pointing at. P50 Flex P50

Sensor Change The sensor in the P50 probe can now easily be changed by the customers themselves. The sensor key (P/N 598-147) will make the changing process easy. Note: when changing sensor the ISH2000 should be calibrated to ensure correct measuring data

Menu System New or changed functions: 1 Reference value 2 Reference unit 3 Correlation value 4 Multipoint Analyse 5 Multipoint Analyse Time 6 Audio Thresold 7 Show Reject Level 8Audio Ready Pulse 9 Reset Signal 10 Invert Colors 11 Probe Button 12 Probe Lamp 13 Audio Base Frequency 14 Info 15 System reset 16 Trigger Level 17 Number of Significant Digits 18 Service Mode

Menu System Reference value: Should be equal to the value stated on the reference leak certificate. If the reference leak value is 4.2E-5 mbarl/s, then you should in the reference value field write 4.2E-05. Reference unit: Should be same as stated on reference leak certificate. If reference gas is used the unit should be PPM Correlation value: Conversion value between different units (needs to be calculated prior to entering the data in the Correlation value field) Multipoint Analysis: Summing up of the analysis results. Set a numeric value between 1 and 25 in this field to sum up the total leakage from all test points. The total value is used to determine if the object is leaking or not (above or below the reject point). Can only be used in Analysis or Combined Mode of the instrument. The APC function is not active when Multipoint is active. Multipoint Analysis Time: Min. time for Multipoint Analysis.

Menu System Audio Threshold: The instrument can be set to be silent to a pre-defined % of the Leak Alarm Level Audio Ready Pulse: Sound is set to pulsating tone or no sound (silent) Show Reject Level: Displays the set Reject Level value in the display

Menu System Reset Signal: Resets the sensor level in Analysis and Detection Mode. Invert Colors: Invert screen colors. Probe Button: Changes probe button functions, switch between Analysis and Detection mode Zero set detected signal in Analysis and Detection mode Initiate sample cycles (Multipoint measurement) Send values from the Probe to printer port Probe light on and off Probe Lamp:

Menu System Audio Base Frequency: Adjusts the tone of the sound between 300 - 700hz in Analysis and Detection Mode Info: Information about program version, serial number and internet contact information System reset: resets all parameters to factory setting Trigger Level: Max level for ”Peak Hold” in Analysis mode (noise reduction) Number of Significant Digits: Number of digits after decimal point Service Mode: Used to identify sensor status and signal status in the instrument

Combox When the Sensistor ISH2000 is connected to other Probes than P50, an adapter ”Combox” must be connected in-between Combox

www.inficon.com