Investigation of diamond sensors for calorimetry

Slides:



Advertisements
Similar presentations
Design Studies and Sensor Test for the Beam Calorimeter of the ILC Detector E. Kuznetsova DESY Zeuthen.
Advertisements

New approach to simulate radiation damage to single-crystal diamonds with SILVACO TCAD Florian Kassel, Moritz Guthoff, Anne Dabrowski, Wim de Boer.
17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensors for the ILC forward calorimeter K. Afanaciev, Ch. Grah,
17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensor materials K. Afanaciev on behalf of FCAL collaboration.
17-May-15FCAL collaboration meeting. Krakow.. Radiation hardness of GaAs Sensors K. Afanaciev, Ch. Grah, A. Ignatenko, W. Lange, W. Lohmann, M. Ohlerich.
17-May-15FCAL collaboration workshop, Status of sensor R&D in Minsk K. Afanaciev, M. Baturitsky, I. Emeliantchik, A. Ignatenko, A. Litomin, V. Shevtsov.
Characterization of primed state of CVD diamond by light and alpha particles C. Manfredotti Experimental Physics Department University of Torino INFN-
Radiation Hard Sensors for the BeamCal of the ILC C. Grah FCAL Collaboration 10 th ICATPP Conference, Villa Olmo.
Optical and electrical characterization of 4H-SiC detectors R. Schifano, A. Vinattieri INFM - Dipartimento di Fisica, Universita ’di Firenze ( Italy) S.
DIAMOND ACTIVITIES DESY Zeuthen Wolfgang Lange. MOTIVATION and PEOPLE: Calorimetry in an environment with high radiation doses (TESLA beam cal) Beam diagnostics.
Measurements on single and poly crystal diamond samples at CERN Luis Fernandez-Hernando Christoph Ilgner Alick Macpherson Alexander Oh Terry Pritchard.
Investigation of the properties of diamond radiation detectors
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Measurements on Single and Poly Crystal CVD Diamond Sensors
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
August 2005Snowmass Workshop Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Current Status of Diamond Sensors R&D in Minsk Group FCAL Collaboration Institute of Nuclear Physics PAN February 12-13, 2006, Krakow, Poland.
Radiation Hard Sensors for the Beam Calorimeter of the ILC C. Grah 1, R. Heller 1, H. Henschel 1, W. Lange 1, W. Lohmann 1, M. Ohlerich 1,3, R. Schmidt.
FCAL R&D in Minsk Group: Sensors and Electronics FCAL Collaboration MPI Munich October 17, 2006, Munich, Germany Presented by Igor Emeliantchik.
The contribution from The contribution from photoluminescence (PL) Gordon Davies, King’s College London.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
3rd NoRDHia 1 TITLE INVESTIGATION OF A SINGLE CRYSTAL DIAMOND SENSOR AND ITS APPLICATION IN BACKGROUND MEASUREMENTS FOR HERA Wolfgang Lange,
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
SILICON DETECTORS PART I Characteristics on semiconductors.
14 December nd CARAT Workshop, GSI, Darmstadt1 Radiation hardness studies with relativistic electrons Sergej Schuwalow, Uni-HH / DESY On behalf of.
Calorimeter technologies for forward region instrumentation K. Afanaciev 2, R. Dollan 1 V. Drugakov 2, C. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
March 2004LCWS Stanford Instrumentation of the Very Forward Region of a Linear Collider Detector Wolfgang Lohmann, DESY.
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C. Grah 1, U. Harder 1, H. Henschel 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1, M.
2. December 2005Valencia Workshop Very Forward Region Instrumentation Wolfgang Lohmann, DESY Basic functions: - Hermeticity to small polar angles - Fast.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
July 2006ALCWS Vancouver Very Forward Instrumentation of the Linear Collider Detector On behalf of the Wolfgang Lohmann, DESY.
September 2006 / 1. / 2 1) GaAs, who needs it anyway ? 2) IV - Measurments 3) IT - Measurments 4) CCD - Measurments Overview.
First results from silicon and diamond sensors K. Afanasiev 1, I. Emeliantchik 1, E. Kouznetsova 2, W. Lohmann 2, W. Lange 2 1 NC PHEP, Minsk 2 DESY Zeuthen.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
Development of Particle Detectors on the Base of Minsk Synthetic Monocrystalline Diamond K.Afanaciev, M.Batouritski, V.Gilewsky, G.Gusakov, I.Emeliantchik,
Investigation of CVD Diamonds as Sensor Material for BeamCal Alexandr Ignatenko FCAL Collaboration Meeting, Orsay October 6-7, 2007.
Electrical features of diamond sensors D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
We are investigating the dependence of efficiency of diamond detector samples on accumulated radiation dose. We have Sr 90  -source of known activity.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, E. Kouznetsova, W. Lange, W. Lohmann.
Albuquerque 1 Wolfgang Lohmann DESY On behalf of the FCAL collaboration Forward Region Instrumentation.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
October DESY PRC Instrumentation of the Very Forward Region of a Linear Collider Detector Univ. of Colorado, Boulder, AGH Univ., INP & Jagiell.
CNS CVD Diamond S. Michimasa. Properties of diamond Extreme mechanical hardness and extreme high thermal conductivity Broad optical transparency in region.
C. Weiss 1, 2, G. Badurek 2, E. Berthoumieux 3, M. Calviani 1, E. Chiaveri 1, D. Dobos 1, E. Griesmayer 4,C. Guerrero 1,E. Jericha 2, F. Kaeppeler 5, H.
Diamond Sensor Tests for the CMS BCM Alexandr Ignatenko FCAL collaboration meeting May 7, 2008.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
Diamond – Tungsten Calorimeter LCAL-group : K. Afanasiev, V. Drugakov, E. Kouznetsova, W. Lohmann, A. Stahl Workshop on Forward Calorimetry and Luminosity.
Charge collection studies with irradiated CMOS detectors
Univ. of Colorado, Boulder, AGH Univ., INP & Jagiell. Univ. Cracow,
Kröhnke, 14 November 2012 FCAL Collaboration Meeting Sergej Schuwalow
Testbeam measurements with diamond sensors. Preliminary results
Strong infrared electroluminescence from black silicon
大強度
Diamond Research Status in Minsk Group
Testbeam Results for GaAs and Radiation-hard Si Sensors
Performance test of ACEM-detector (Aluminum Cathode Electron Multiplier) Marcus Palm AB-ATB-EA M. Palm, CERN.
Radiation hard sensors for ILC forward calorimeter
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
The MPPC Study for the GLD Calorimeter Readout
A DLC μRWELL with 2-D Readout
Diamond Measurements in Zeuthen
Presentation transcript:

Investigation of diamond sensors for calorimetry K. Afanaciev 1, I. Emeliantchik 1, A. Ignatenko 1, E. Kouznetsova 2, W. Lohmann 2, C. Grah 2 1 NCPHEP, Minsk; 2 DESY, Zeuthen, ECFA ILC Workshop, Vienna, 2005

Application ILC Detector forward calorimeter BeamCal: Sampling diamond-tungsten calorimeter Expected dose from beamstrahlung is about 10 MGy per year Large area detector is needed

Detection mechanism Diamond works as a solid state ionization chamber Charge carriers, generated by ionizing particle move in an external electric field and induce charge on the surface electrodes This charge is detected by a charge-sensitive preamplifier

The samples Chemical vapor deposited (CVD) polycrystalline samples: A large number of samples from Fraunhofer IAF, Freiburg 12x12 mm plates with thickness 200 - 700 m Metallization: 10 nm Ti + 400 nm Au 1 pad or 4 pad segmentation samples from GPI, Moscow samples from Element Six HPHT synthetic monocrystalline samples: From ADAMAS BSU Typical size 4x4 mm, thickness 300 - 600 m Metallization: Fe-Ni with B ion implantation 1 sample of natural monocrystalline diamond

IV Measurement Most of the samples show ohmic behavior and very high resistance in the order of 1013-1014 ohm Settling time of the current is in the order of 100 s. Hysteresis is due to long settling time of the signal.

Charge collection distance Performance of diamond as particle detector is usually characterized by charge collection efficiency  or distance (CCD) Efficiency is given by  = Qmeas/Qind where Qmeas is measured charge and Qind - total charge generated Charge collection distance equals CCD = *d where d is the thickness of the sample CCD could be considered as the drift distance between the charge carrier pair before trapping

CCD Measurement To measure CCD we need to know the amount of charge carriers generated But we know that a MIP generates about 36 e--h pairs per 1 m pathlength in diamond Sr90 & Gate PA discr delay ADC In this case CCD = Qmeas /36 diamond Scintillator allows triggering only from particles which could be considered MIPS Scint. PM1 PM2

CCD Measurement Pedestal (random trigger) Signal (MIP trigger) Signal charge value could be calculated from this pair of spectra by subtracting pedestal and multiplying by charge/ADC channel value from calibration. The signal is fitted to the Landau distribution

CCD Results

CCD vs HV and time Charge collection distance depends on bias voltage applied to the sample Saturation is observed at field strength of about 1V/m There is also dependence of CCD on time with HV on About 25% signal decrease

CCD vs Dose Diamond is stable under irradiation with doses up to 10 MGy But in the process of irradiation the signal properties could change Most of the samples show similar behavior CDD is rising with the dose by approx. 10-20% and then stabilizes But some samples show complete degradation of signal and sharp rise of the current under irradiation

Trapping Trapping of the charge carriers is the main cause of low CCD. Traps could be impurities, defects and other irregularities of crystalline structure. Filling of traps produces space charge in the crystal and could give rise to polarisation effects If we have several trapping levels with different activation energy, density and cross section, the dynamics of trapping will be really weird. For now we have three methods of investigation of trapping levels: TSC, PL and Raman

TSC measurements TSC means thermally stimulated currents The idea is that if we have charge carrier trapping in the diamond at room temperature, then heating the sample up could free trapped charge carriers and produce detectable current. The current peak position vs temperature gives the idea about energy levels of traps. Setup consists of heating plate electronic thermometer with thermopair, HV supply and picoammeter

TSC measurements Peak position corresponds to energy of about 0,8-1 eV FAP21, 100 V TSC “resets” sample, but the shape is similar for different samples

Linearity A linear behavior over a large dynamic range is required for the calorimetry application. We have checked this with a beamtest at CERN Setup consists of a box with diamond and preamplifier and scintillator trigger box Incident hadronic beam with approx. 4 GeV energy and intensity from 105 / s up to 104 - 108 / 10ns

Linearity Signal at high intensity clearly visible w/o preamplifier Good linearity for two samples over the dynamic range of 102 (flux approx. 2x104-3x106 MIP/cm2 per 10 ns) MIP on the same scale FAP2.2 E 6-4

Linearity Particle flux Sample response particle flux E 6-4

PL Spectra Photoluminescence spectra of different samples Si There seems to be a correlation between detector properties and PL

Raman Spectra For diamond the Raman line is 1332.5 cm-1 at 300 K. The presence of graphite in a diamond causes a strong line at 1580cm-1, microcrystalline graphite provides also a 1355cm-1 line. Amorphous carbon gives a broad peak between 1100 and 1700cm-1 E6 150 m FAP5 40 m FAP23 10 m

Conclusion Future work Diamond sensors work and we have results both from CVD and synthetic monocrystalline diamonds. The sensors have good radiation hardness and linear response. The CCD vs time behavior and dependence of CCD on dose needs further investigation. . Future work Need to establish close contact with manufacturer, find a method to characterize samples (PL, Raman) and get interpretation from the material scientists A study of radiation hardness with large doses is planned A new batch of samples is ready for tests.

Diamond as detector Diamond have very high radiation hardness (doses up to 10 MGy) This makes diamond very promising material for the next generation colliders It also have unique properties, such as low conductivity, high thermoconductivity, wide bandgap, chemical inertness

Testbeam pad1 pad3 pad2 pad4 diamond 10x10 mm scint. 5x 5 mm Misalignment or change in the beam profile which wasn’t seen by scint.