Liquid Xenon Detector for the MEG Experiment

Slides:



Advertisements
Similar presentations
27/Jan/2005 K. Ozone 2004 年度博士論文審査会 Contents 1. MEG experiment 2. LXe Purification 3. Prototype Performance 4. Expected Performance 5. Toward the MEG experiment.
Advertisements

Liquid Xenon Photon Detector Satoshi MIHARA ICEPP, Univ. of Tokyo
Liquid Xenon Carlorimetry at the MEG Experiment Satoshi MIHARA Univ. of Tokyo.
Prospects for 7 Be Solar Neutrino Detection with KamLAND Stanford University Department of Physics Kazumi Ishii.
Shuei YAMADA, ICEPP, University of tau04 Nara, Sep. 15, Search for the Lepton Flavor Violating Decay  e  in the MEG Experiment Shuei YAMADA.
XEC Hardware Status MEG Review Meeting 2010 Liquid Xenon Group.
Yasuhiro NISHIMURA Hiroaki NATORI The University of Tokyo MEG collaboration Outline  → e  and MEG experiment Design of detector Calibration Performance.
Xenon Detector Status Liquid Xenon Detector Group.
Upgrade of liquid xenon gamma-ray detector in MEG experiment Daisuke Kaneko, the University of Tokyo, on behalf of the MEG collaboration MEG EXPERIMENT.
Wataru Ootani, ICEPP, Univ. of Tokyo SORMA X, May 21, 2002 Development of liquid xenon scintillation detector for new experiment to search for   e 
Malte HildebrandtMEG Review Meeting, 14th February 2007 Report of Run Coordinator Run 2006 Summary Malte Hildebrandt MEG Review Meeting, 14th February.
Mar Toshiyuki Iwamoto (ICEPP) JPS 2010 Spring meeting, Okayama University1 MEG 実験による   e  探索 Run2009 東京大学素粒子物理国際研究センター 岩本敏幸 他 MEG コラボレーション.
Satoshi Mihara ICEPP, Univ. of Tokyo Feb MEG Review Meeting 1 CEX beam test at piE1 Satoshi Mihara.
Liquid Xenon Photon Detector Feb MEG Review Meeting Liquid Xenon Detector Part I CEX beam test at piE1 Oct-Dec/03 –Hardware operation status –Analysis.
Report of the NTPC Test Experiment in 2007Sep and Others Yohei Nakatsugawa.
Conveneers: M. Grassi (INFN, Pisa), K. Ishida (RIKEN), Y. Semertzidis (BNL) Summary of WG4, Part Two. Yannis Semertzidis, BNL 1 August, 2004 Most muon.
2 1/March/2015 日本物理学会大70回年次大会@早稲田大学 東大ICEPP 内山雄祐 他 MEG II collaboration.
Analysis of PSI beam test R.Sawada 09/Feb/2004 MEG collaboration R.Sawada 09/Feb/2004 MEG collaboration
MEG positron spectrometer Oleg Kiselev, PSI on behalf of MEG collaboration.
19 April 2006Fabrizio Cei1 The Liquid Xenon Calorimeter of the MEG Experiment Fabrizio Cei INFN and Universita’ di Pisa Incontri di Fisica delle Alte Energie.
Update of the DeeMe spectrometer design and its performance Nguyen Duy Thong, Masaharu Aoki, Doug Bryman C, Satoshi Mihara A, Yohei Nakatsugawa A, Hiroaki.
MEG II 実験 液体キセノンガンマ線検出器に用いる 光検出器 MPPC の 実装に向けた最終試験 家城 佳 他 MEG II collaboration + 九大の方々.
Possible calibration methods for the final LXe calorimeter A. Papa 01/20/2004.
MEG 2009 現状と展望 東京大学素粒子物理国際研究センター 岩本敏幸 他 MEG コラボレーション 日本物理学会 2009 年秋季大会 甲南大学岡本キャンパス.
MEG 実験用液体キセノン検出器の現状 東京大学素粒子物理国際研究センター 澤田龍 他 MEG カロリメータグループ 2007 年 9 月 24 日 日本物理学会 第 62 回年次大会 北海道大学.
Lead Fluoride Calorimeter for Deeply Virtual Compton Scattering in Hall A Alexandre Camsonne Hall A Jefferson Laboratory October 31 st 2008.
1 Satoshi Mihara for the   e  collaboration, review meeting at PSI, Jul 2002 Photon Detector Satoshi Mihara ICEPP, Univ. of Tokyo 1.Large Prototype.
Dec. 8th, 2000NOON A new   e  experiment at PSI For the MUEGAMMA collaboration Stefan Ritt (Paul Scherrer Institute, Switzerland) Introduction.
Calibration and monitoring of the experiment using the Cockcroft-Walton accelerator G. Signorelli Sezione di Pisa MEG Review meeting - 20 Feb On.
MEG Run 2008 液体キセノンガンマ線検出器 東京大学 素粒子物理国際研究セン ター 西村 康宏、 他 MEG コラボレー ション 2008 年秋季物理学会@山形大学小白川キャンパス.
Possible calibration methods for the final LXe calorimeter A. Papa 02/11/
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
J-PARC でのハイパー核ガンマ線分光実験用 散乱粒子磁気スペクトロメータ検出器の準備 状況 東北大理, 岐阜大教 A, KEK B 白鳥昂太郎, 田村裕和, 鵜養美冬 A, 石元茂 B, 大谷友和, 小池武志, 佐藤美沙子, 千賀信幸, 細見健二, 馬越, 三輪浩司, 山本剛史, 他 Hyperball-J.
Liquid Xe detector for m +  e + g search Kenji Ozone ( ICEPP, Univ. of Tokyo, Japan ) Introduction prototype R&D ー PMTs ー small & large type summary Outline.
Current status of XMASS experiment 11 th International Workshop on Low Temperature Detectors (LTD-11) Takeda Hall, University of Tokyo, JAPAN 8/1, 2005.
R&D works on Liquid Xenon Photon Detector for μ  e γ experiment at PSI Satoshi Mihara ICEPP, Univ. of Tokyo Outline Introduction Prototype R&D works Summary.
A. Baldini PSI July 05 Overview of the experiment MEG is being built (Beam line, Magnet, LXe, DC, TC, Elect., Software) Delays in some items: O(months)
MEG 実験 2009 液体キセノン検出器の性能 II 西村康宏, 他 MEG コラボレーション 東京大学素粒子物理国際研究セン ター 第 65 回年次大会 岡山大学.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
1 PMT Univ. of Tokyo Yasuko HISAMATSU ICEPP, MEG Collaboration meeting Feb. 10th, 2004.
g beam test of the Liquid Xe calorimeter for the MEG experiment
MEG Experiment Data Analysis: a status report
Spokesman's update.
The Electromagnetic calorimeter of the MEG Experiment
Cecilia Voena INFN Roma on behalf of the MEG collaboration
New experiment to search for mge g at PSI status and prospects
大強度
MEG Experiment at PSI R&D of Liquid Xenon Photon Detector
Stato del calorimetro elettromagnetico
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
Upgrade of LXe gamma-ray detector in MEG experiment
On behalf of the GECAM group
Upgrade of LXe gamma-ray detector in MEG experiment
The First
Upgrade of LXe gamma-ray detector in MEG experiment
A personal overview of particle physics activities at PSI
MEG実験アップグレードに向けたSiPMを用いた ポジトロン時間測定器の研究開発
MEG実験の液体Xe検出器について 東大 ICEPP  森研究室 M1 金子大輔.
Stefan Ritt Paul Scherrer Institute, Switzerland
Liquid Xenon Scintillation Detector for the MEG Experiment
The MEG Detector to Search for m -> eg Decays
MEG II実験 液体キセノン検出器の建設状況
Daisuke Kaneko, ICEPP, Univ. of Tokyo on behalf of MEG collaboration
MEG Summary T. Mori for MEG Collaboration February 9, 2005.
COherent Muon to Electron Transition (COMET)
Xenon Detector Hardware
Decay Angular Measurement in the MEG Experiment
New Results from the MEG Experiment
Presentation transcript:

Liquid Xenon Detector for the MEG Experiment Toshiyuki Iwamoto 4/Oct/2006 10th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD06) Siena 4/Oct/2006 Siena 2006

MEG Physics Lepton flavor violating process already violated in neutrino sector Forbidden in the Standard Model Sensitive to the new physics models, SUSY GUT, or SUSY seesaw etc. The present experimental limit ~ 1.2x10-11 by MEGA experiment Clear 2-body kinematics Ee = Eg = 52.8 MeV Back to back (qeg = 180°) Simultaneous (Te = Tg) 4/Oct/2006 Siena 2006

Sensitivity Background Radiative m decay : m+  e+ nm ne g < 10-14 Accidental overlap: m decay m  e n n + random g To reject these background, energy, timing and vertex resolution pile-up rejection from waveform analysis Single event sensitivity ~ 4x10-14 Background event ~ 4x10-14 90% C.L. sensitivity ~ 1x10-13 photon detector requirement DEg = 5% (FWHM) DTg = 150ps (FWHM) DXg = 9mm (FWHM) MEGA MEG 4/Oct/2006 Siena 2006

MEG detector Approved in 1999 at PSI Physics run in 2007 4/Oct/2006 Siena 2006

MEG Detector 590 MeV proton Ring Cyclotron Drift chamber COBRA magnet w/ graded B field Most intense DC muon beam (108/s) H. Nishiguchi, 5th Oct “The MEG positron spectrometer” Timing counter Photon detector 4/Oct/2006 Siena 2006

Photon Detector 800 liter liquid xenon, 846 2” PMTs in liquid High light yield, fast response and good uniformity (~40000ph/MeV, t=4.2, 22, 45ns) Low temperature (~160K), l = 178nm : development of PMT, refrigerator Xenon purity : remove H2O Performance test of Xe detector 2.3 liter prototype confirmed the principle of Xe 68.6 liter prototype 10, 20, and 40 MeV inverse Compton scattering g energy, timing and vertex resolution 55, 83MeV, 129MeV g from p-p->np0,ng reaction energy, and timing resolution 4/Oct/2006 Siena 2006

Improvement Purification Gas & Liquid phase purification tested PMT Q.E. : ~15% Photocathode : K-Cs-Sb Metal channel dynode, 12 stages Silica window (for UV light) Compact, and low heat load Tolerance up to 100G magnetic field Al strip to keep surface resistance at low temp. Zener diode for high rate background Purification Gas & Liquid phase purification tested Metal getter (zirconium) by gas ~0.5l/h Molecular sieves by liquid ~100l/h 1m 57mm 2.5m 4/Oct/2006 Siena 2006

Prototype test, 10~40MeV g 68.6l liquid xenon prototype detector 228 PMTs 40MeV g Energy 1.6% in s s ~ 4mm Vertex distribution 4/Oct/2006 Siena 2006

Prototype test, 55~129MeV g H2 target Prototype LXe LYSO g g NaI p- Opening angle (q) Energy (MeV) 83MeV H2 target Prototype LXe LYSO g g 175° 170° NaI 55MeV p- m phe Xenon detector p- (at rest) + p -> p0 + n, p0(28MeV/c) -> g + g (54.9MeV<Eg<82.9MeV) Almost monochromatic g is available p- + p -> n + g (129MeV) Energy, timing resolution neutron response 4/Oct/2006 Siena 2006 ENaI + ELYSO (MeV)

Photon detector performance Energy distribution @ 55MeV 5% 1% Energy resolution vs. Energy = 1.23 ±0.09 % FWHM=4.8 % Energy Resolution (s) [%] Timing distribution 110 psec Expected Performance Energy : 5% (FWHM) Timing : 150 psec (FWHM) Vertex : 9mm (FWHM) 110 - 64 (LYSO) - 61 (Beam) = 65psec 4/Oct/2006 Siena 2006

Detector operation 250l gas xenon tank x 8 purifier Refrigerator 1000l liquid xenon storage tank 4/Oct/2006 Siena 2006

Calibration method Gain monitor : LED Q.E. : 241Am a source 3x3 Energy 55, 83, and 129 MeV g from p-pp0n, p02g Ni thermal n capture 9MeV Proton accelerator Li(p,)Be 17.6MeV B(p,)C 16.1MeV Timing Laser radiative m decay 55 MeV g from p-pp0n reaction (Pb+Scintillator) Vertex 55 MeV g from p-pp0n reaction (collimator) 3x3 NaI array LH2 target 4/Oct/2006 Siena 2006

Detector Construction 4/Oct/2006 Siena 2006

Detector Construction top outer side inner The performance of all PMTs checked in the liquid xenon before installation 4/Oct/2006 Siena 2006

Schedule Cryostat will come to PSI in the end of this year PMT installation into holders almost done Liquid xenon detector assembly will be done in the beginning of next year, and then liquefaction, purification and stable operation test will be continued. physics run starts in 2007 Positron spectrometer run and calibration run will be done in this year 4/Oct/2006 Siena 2006

Summary MEG experiment will search for m->eg with better sensitivity than previous experiment The performance of liquid xenon detector has been tested by using prototype, and the real detector is being constructed Physics run of MEG experiment will start in 2007. Positron spectrometer data and calibration data will be taken in this year. 4/Oct/2006 Siena 2006