Honeywell Spyder™ Programmable Controllers

Slides:



Advertisements
Similar presentations
Spyder® Introduction.
Advertisements

Spyder Sylk™ Enhanced October 2008.
Multi-Loop PID Controllers All Watlow® multi-loop time/temperature controllers offer auto-tuning which automatically sets PID control parameter for optimum.
Invensys  D irect D igital C ontrol. Invensys  Direct Digital Control : 1.Hardware. 2.Software. 3.Firmware. 4.Local DDC Controllers. 5.Types of I/O.
Digital Celeris Integrated System Patient Room Isolation Room Programmable Controllers Local Display & Command Unit.
1 RIO Pocket PLC. 2 Smart. Compact. Low Cost. Lots of I/O. Smart – RISC processor, memory, pulse counters, PID process loops, web interface, capability,
DCS550 Sales Presentation
PROGRAMMABLE LOGIC CONTROLLERS PLC’S
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
Honeywell Spyder™ Programmable Controllers
Title Subtitle WebVision Product Overview. 2© HONEYWELL WebVision Overview: Outline Introduction - Portfolio-fit - Architecture Product.
Introduction.
ASPPRATECH.
PLC: Programmable Logical Controller
Technical Training LAB Models D-Line. Characteristics Fully Automatic User Friendly Fixed Programs Up to 20 customizable programs Available from 28 to.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Zio®/Zio Plus Sales Overview. 2HONEYWELL - CONFIDENTIAL2 Zio® / Zio Plus LCD Wall Module Feature Brief Used with Spyder® with Sylk® controller Two-wire.
Spyder Reflash Tool.
SCADA and Telemetry Presented By:.
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
MARCO UNICOS based control system CERN Lukasz Zwalinski – PH/DT Maciej Ostrega – PH/DT.
Owner: VBHUSales Training 03/15/2013 Cypress Confidential IDT 72T36135M vs. Cypress CYF072x Video Buffering Applications High density FIFOs with unmatched.
Samuel John Vinod Kumar CG Ganesh Raam K. Introduction  The need for health consciousness has increased in the recent past and so is the need to monitor.
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
Zio™ TR70 LCD Wall Module Customer Training.
HYDRO MULTI-B – Pressure boosting made simple The CU323 1) Power in. 2) Internal Geni 3) Optional CIM Module 4) Analog input 5) PTC terminals 6) DI terminals.
© Date: 10/07 vinvin Product Presentation High-Speed, Microcontroller-adaptable, PWM Controller MCP1631 October 2007.
Programmable Controllers - ECL/ECB
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Spyder® BACnet® March 2009.
VAV Terminal Applications Programmable Controllers - ECB / ECL-VAV Series.
Time Saving Tools to Benefit Your Bottom Line Brought to you by: E5xA Power & Energy Meter.
CompactLogix Controllers Portfolio
Top 10 Differentiators.
Zio®/Zio Plus Sales Overview. 2HONEYWELL - CONFIDENTIAL2 Zio® / Zio Plus LCD Wall Module Feature Brief Used with Spyder® with Sylk® controller Two-wire.
HVAC Programmable Controllers -PTU
A Competitive Overview Jon Cramer and Steve Floth Regional Sales Managers.
1 Microcontrollers. 2 Programmers work in the virtual world Machinery works in the physical world Microcontrollers connect the virtual and physical world.
Arduino Week 3 Lab ECE 1020 Prof. Ahmadi. Objective Data acquisition (DAQ) is the process of measuring an electrical or physical phenomenon such as voltage,
Modular C ontroller S eries Product Introduction.
Components of Mechatronic Systems AUE 425 Week 2 Kerem ALTUN October 3, 2016.
“The Industrial Workhorse”
Tago Tago IoT DAY GRAIN BIN LEVEL? The epicenter of middleware
Honeywell Sylk™ I/O Modules
Microcontrollers, Basics Fundamentals of Designing with Microcontrollers 16 January 2012 Jonathan A. Titus.
@ Professor Doug Harper Department of Physics and Astronomy
Spyder® Micro March 2009.
Text آشنایی بیشتر با کنترلر هوشمند زیمنس
UNICOS: UNified Industrial COntrol System CPC (Continuous Process Control) Basic course SESSION 3: PLC basics UCPC 6 UNICOS-Continuous Process Control.
Application Specific VAV Controller
LDA Large Display for Analog Inputs
FP-7 Programmable Controller Multi Input/Output unit
SIO-RTD RTD MODULE.
Session III Architecture of PLC
הודעות ריענון מהיר והרחבות Charts & Graphs גרף XY בניית מחולל אותות
Programmable Logic Controllers
Talking to SAM - Network Communications for NeSSI
MicroLogix Packaged Controllers
IzoT™ Routers and Network Interfaces
Delta PLC AH500 Series for High-End Automation System Applications Automation for a Changing World.
Data Acquisition (DAQ)
Agenda Introduction Building Management System Architectures
Manual Robotics ..
DeviceNet Communication Solution for Discrete Devices
‘‘ BUILDING AUTOMATION’’
TR20 Series Wireless Training Slides
Detailed information FOR INTERNAL USE ONLY! CUBE20.
GasGard 100 Control System
05 | Integrating Advanced Sensors and Shields
Presentation transcript:

Honeywell Spyder™ Programmable Controllers

Honeywell’s Spyder controllers The power and flexibility of a plant controller inside the compact package of a unitary controller

Spyder Offers More Features to Solve Spyder BACnet Spyder Offers More Features to Solve Today’s Problems Sylk Bus for TR71, TR75 and other future Sylk Devices Fully Programmable Removable Terminal Strips Color Coded Terminals Internal Real-Time Clock Internal DC Power Supply VAV with Integrated Actuator

Programming Tool Industry’s First Unified Tool Automatically convert your Lon applications to BACnet Same programming environment for Lon and BACnet

Spyder VAV Controllers with Actuator Model Programmable Type UI DI AO DO Velocity Pressure Sensor (Microbridge) Series 60 Floating Actuator PV*6436AS VAV 6 4 3 YES PV*4022AS 2 PV*0000AS * = L for Lon, B for BACnet MS/TP 2 Digital Outputs reserved for Integrated Actuator Integrated Pressure Sensor a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output

Spyder VAV Controller w/o Actuator Model Programmable Type UI DI AO DO Velocity Pressure Sensor (Microbridge) Series 60 Floating Actuator PV*6438NS VAV 6 4 3 8 YES NO PV*4024NS 2 * = L for Lon, B for BACnet MS/TP Integrated Pressure Sensor a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output

Spyder Unitary Controller Model Programmable Type UI DI AO DO Velocity Pressure Sensor (Microbridge) Series 60 Floating Actuator PU*6438S Unitary 6 4 3 8 NO PU*4024S 2 PU*1012S 1 * = L for Lon, B for BACnet MS/TP Extended Temperature Rating a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output

Controller Architecture Communication bus (Lon or BACnet MS/TP) Programmable Unitary Controllers Programmable VAV Controllers with Actuator Programmable VAV Controllers w/o Actuator Programmable Unitary Controller Extended Temperature Rated -40° F (-40° C) to 150° F (65.5° C) Programmable Variable Air Volume Controller Integrated actuator Integrated on-board pressure sensor Programmable Variable Air Volume Controller Integrated on-board pressure sensor PU*1012S Inputs 1 universal input 0 digital inputs Outputs 1 analog output 2 digital outputs PU*4024S 4 universal inputs 2 analog outputs 4 digital outputs PU*6438S 6 universal inputs 4 digital inputs 3 analog outputs 8 digital outputs PV*0000AS Inputs 0 universal inputs 0 digital inputs Outputs 0 analog outputs 0 digital outputs PV*4022AS 4 universal inputs 2 analog outputs 2 digital outputs PV*6436AS 6 universal inputs 4 digital inputs 3 analog outputs 6 digital outputs PV*4024NS Inputs 4 universal inputs 0 digital inputs Outputs 2 analog outputs 4 digital outputs PV*6438NS 6 universal inputs 4 digital inputs 3 analog outputs 8 digital outputs a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output * = L for Lon, B for BACnet MS/TP

Why Choose the Spyder Platform? Both Lon and BACnet available Both protocols available Single Tool Spyder is the only controller that has a common programming interface for Lon and BACnet Any existing Spyder programs or libraries can be converted to either Lon or BACnet Programmable Create custom applications to meet any need Multiple I/O and protocol options Select the controller that meets your needs Application Library Easy re-use of applications, standard applications available

www.honeywell.com