Honeywell Spyder™ Programmable Controllers
Honeywell’s Spyder controllers The power and flexibility of a plant controller inside the compact package of a unitary controller
Spyder Offers More Features to Solve Spyder BACnet Spyder Offers More Features to Solve Today’s Problems Sylk Bus for TR71, TR75 and other future Sylk Devices Fully Programmable Removable Terminal Strips Color Coded Terminals Internal Real-Time Clock Internal DC Power Supply VAV with Integrated Actuator
Programming Tool Industry’s First Unified Tool Automatically convert your Lon applications to BACnet Same programming environment for Lon and BACnet
Spyder VAV Controllers with Actuator Model Programmable Type UI DI AO DO Velocity Pressure Sensor (Microbridge) Series 60 Floating Actuator PV*6436AS VAV 6 4 3 YES PV*4022AS 2 PV*0000AS * = L for Lon, B for BACnet MS/TP 2 Digital Outputs reserved for Integrated Actuator Integrated Pressure Sensor a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output
Spyder VAV Controller w/o Actuator Model Programmable Type UI DI AO DO Velocity Pressure Sensor (Microbridge) Series 60 Floating Actuator PV*6438NS VAV 6 4 3 8 YES NO PV*4024NS 2 * = L for Lon, B for BACnet MS/TP Integrated Pressure Sensor a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output
Spyder Unitary Controller Model Programmable Type UI DI AO DO Velocity Pressure Sensor (Microbridge) Series 60 Floating Actuator PU*6438S Unitary 6 4 3 8 NO PU*4024S 2 PU*1012S 1 * = L for Lon, B for BACnet MS/TP Extended Temperature Rating a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output
Controller Architecture Communication bus (Lon or BACnet MS/TP) Programmable Unitary Controllers Programmable VAV Controllers with Actuator Programmable VAV Controllers w/o Actuator Programmable Unitary Controller Extended Temperature Rated -40° F (-40° C) to 150° F (65.5° C) Programmable Variable Air Volume Controller Integrated actuator Integrated on-board pressure sensor Programmable Variable Air Volume Controller Integrated on-board pressure sensor PU*1012S Inputs 1 universal input 0 digital inputs Outputs 1 analog output 2 digital outputs PU*4024S 4 universal inputs 2 analog outputs 4 digital outputs PU*6438S 6 universal inputs 4 digital inputs 3 analog outputs 8 digital outputs PV*0000AS Inputs 0 universal inputs 0 digital inputs Outputs 0 analog outputs 0 digital outputs PV*4022AS 4 universal inputs 2 analog outputs 2 digital outputs PV*6436AS 6 universal inputs 4 digital inputs 3 analog outputs 6 digital outputs PV*4024NS Inputs 4 universal inputs 0 digital inputs Outputs 2 analog outputs 4 digital outputs PV*6438NS 6 universal inputs 4 digital inputs 3 analog outputs 8 digital outputs a – One Universal Input (UI-1*) is user selectable as a fast digital pulse meter UI – Universal Input, DI – Digital Input, AO – Analog Input, DO – Digital Output * = L for Lon, B for BACnet MS/TP
Why Choose the Spyder Platform? Both Lon and BACnet available Both protocols available Single Tool Spyder is the only controller that has a common programming interface for Lon and BACnet Any existing Spyder programs or libraries can be converted to either Lon or BACnet Programmable Create custom applications to meet any need Multiple I/O and protocol options Select the controller that meets your needs Application Library Easy re-use of applications, standard applications available
www.honeywell.com