EPA Method Equivalency

Slides:



Advertisements
Similar presentations
CAP/POCT 2003 Carol Riley-Hunte, RRT Senior Education Specialist Bayer HealthCare.
Advertisements

Radiochemical Methods and Data Evaluation
Why Lab. Certification? Laboratory certification tries to insure that the laboratory is qualified and capable of analyzing the sample and obtaining quality.
Quality is a Lousy Idea-
LABORATORY CERTIFICATION & DATA QUALITY MICHAEL W. MILLER, Ph.D. NJ-DEP Office of Quality Assurance
UNDERSTANDING ENVIRONMENTAL LABORATORY/QC REPORTS Maya Murshak – Merit Laboratories, Inc.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
Office of Water PittCon 2001 Status of EPA Method 1631 for the Determination of Low-Level Mercury Maria Gomez-Taylor Analytical Methods Staff U.S.
Mentoring Session Technical Assistance Committee Method Modifications.
Florida Pilot Initiative for the Performance Approach to Measurement Systems Stephen Arms Florida Department of Health.
Interpreting Your Lab Report & Quality Control Results
World Health Organization
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
Lecture 8. Quality Assurance/Quality Control The Islamic University of Gaza- Environmental Engineering Department Environmental Measurements (EENV 4244)
Quality Assurance/Quality Control Policy
Detect Limits as Representation for a Standard VAP Rule Discussion Dawn Busalacchi Risk Assessor, DERR, Central Office VAP Rule Discussion Dawn Busalacchi.
Quality Assurance Plans (QAP)
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
1 Standard Operating Procedures Their Development and Use with Quality Assurance Project Plans.
Field Analysis Quality Control
Debra Waller NJDEP-Office of Quality Assurance
WWLC Standard Operating Procedures Presented by Frank Hall, Laboratory Certification Coordinator.
VALIDATION METHODOLOGY
Method Validation and Verification: An Overview Patricia Hanson, Biological Administrator I Florida Department of Agriculture and Consumer Services, Food.
Laboratory Technical Issues Presentation to: KWWOA April 9, 2014 Department for Environmental Protection Environmental & Public Protection Cabinet To Protect.
HD 2007 Rule Diesel Fuel Sulfur Testing and Sampling Methods and Requirements US EPA Office of Transportation and Air Quality November 20, 2002.
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Quality Assurance Plan (QAP) Department for Environmental Protection Environmental & Public Protection Cabinet To Protect and Enhance Kentucky’s Environment.
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
Wastewater Laboratory Certification Presented at: KWWOA April17,
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
Laboratory Certification Update Part 2 Common Findings KWWOA Louisville April 15, 2015 Presented by Frank Hall, Laboratory Certification Coordinator.
Forum FM308: Policy Changes Tuesday June 5 10:00 a.m. AIHA Laboratory Accreditation Policy Changes—ISO “How Do Changes Affect My Laboratory?” “What.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
Control Charts and Trend Analysis for ISO 17025
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
Achieving Method Compliance with Innovative Technologies Tony Francis, PhD Principal, SAW Environmental TCEQ – Environmental Trade.
EQUIPMENT and METHOD VALIDATION
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Overview CWA Methods Update Rule Method 608.3
The Method Update Rule Does this affect me? HOW?
Quality is a Lousy Idea-
Clean Water Act Methods Overview of EPA’s CWA Method Activities
An Update to the 40 CFR Part 136 Method Detection Limit
The 2015/2016 TNI Standard and the EPA MDL Update
Method Modifications & ATP 40 CFR part and 136.5
Status of EPA Method 1631 for the Determination of Low-Level Mercury
World Health Organization
EPA Method A Summary of the Changes in the Newly Promulgated GC/MS Method for Volatile Organics in Wastewater Harry McCarty and Kevin Roberts CSRA,
William Lipps Analytical & Measuring Instrument Division August 2017
Janice L. Willey Senior Chemist
The Analysis of Soils and Waters in Accordance with U. S
Have Instrument, make method; How new methods are made and validated
Quality is a Lousy Idea-
Update on ASTM and Standard Methods method development activities
Clean Water Act Methods Overview of EPA’s CWA Method Activities
EPA Method Equivalency
EPA Region 10 Alternate Test Procedures and Method Update Rule
What it Means, Why it Works, and How to Comply
Director of Quality Assurance
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Chapter 5 Quality Assurance and Calibration Methods
Why Use Them? By: Marcy Bolek – Alloway
SDWA Collaborative Efforts Overview
World Health Organization
TCEQ Environmental Trade Fair Water Quality Division
2019 AWOP National Meeting Office of Ground Water and Drinking Water
Presentation transcript:

EPA Method Equivalency Edward F. Askew PhD Askew Scientific Consulting

Method Equivalency Auditor-Laboratory Does It Apply to Me???? Askew Scientific Consulting LLC

Supplier’s Claim: Procedure is equivalent to USEPA and Standard Method 4500-P E for wastewater Fill a sample cell with 10 mL of sample. Add the contents of one Reagent Powder Pillow to the cell. A blue color develops if phosphorus is in the sample. Immediately close the sample cell. Shake vigorously for 20–30 seconds. Add 5.0 mL of sample to a vial. (Vial contains 5 mL liquid reagent) Cap and invert to mix. Using a funnel, add the contents of one dry packet to the vial. Cap the vial tightly and shake for 10-15 seconds. Note: The powder will not completely dissolve. Old Test Kit EPA Letter 1996 & 1999 EPA Approval Letter only for EPA Methods 365.1& 365.2 New Test Kit 2017 Askew Scientific Consulting LLC

What is EQUIVALENCY 40 CFR part 136.6 Askew Scientific Consulting LLC

40 CFR part 136.6 Method Equivalency for Clean Water Act Methods Flexibility to Modify Methods - 40 CFR 136.6 If you use a modification to an approved 40 CFR Part 136 method and document the modification as described at 40 CFR 136.6 , you will no longer receive or require a letter from EPA. The promulgated § 136.6, as modified by the May 18, 2012 Methods Update Rule allows the regulated community more flexibility to modify approved methods without EPA review, provided certain requirements are met. This regulation allows the analytical community greater flexibility to modify approved methods to lower the costs of measurements, overcome matrix interferences, or otherwise improve the analysis without EPA review. Laboratories that modify Part 136 methods may be private, public or commercial and may conduct analyses for one or more clients or facilities. https://www.epa.gov/cwa-methods/alternate-test- procedures Askew Scientific Consulting LLC

DETAILS ?????? My Auditor Is ONSITE !!!! Askew Scientific Consulting LLC

What Is An Allowed Modification As Per 40 CFR part 136.6 Method modifications: If the underlying chemistry and determinative technique in a modified method are essentially the same as an approved part 136 method, then the modified method is an equivalent and acceptable alternative to the approved method provided the requirements of this section are met. However, those who develop or use a modification to an approved (part 136) method must document that the performance of the modified method, in the matrix to which the modified method will be applied, is equivalent to the performance of the approved method. Supporting documentation must, if applicable, include the Routine initial demonstration of capability and Ongoing QC including Determination of precision and accuracy, Detection limits, Matrix spike recoveries. Askew Scientific Consulting LLC

MORE DETAIL My Auditor Wants More Information Askew Scientific Consulting LLC

Clarification of 40 CFR part 136.6 Requirements Richard Redding Memo: Flexibility to Modify CWA Methods, November 20, 2007 https://www.epa.gov/sites/production/files/2015-08/documents/cwa-method- flexibility_memo_11-20-2007.pdf Developer Responsibilities Provide the laboratory with a side-by side method comparison table The developer should provide to its customers an in-depth comparison of the modified method with the EPA approved method, and document the comparison in a two-column method comparison table. The two-column method comparison table shall include the number and title of each method, the latest revision date of the modified method and a detailed discussion of each of the 17 topics required by the standard EPA method format. Askew Scientific Consulting LLC

Verify that all items of the "Equivalency Checklist" are met: The developer should provide to their clients the modified method written in the standard EPA format: http://www.epa.gov/waterscience/methods Provide a copy of the data comparing the modified method performance to the approved method to demonstrate that the method is capable of yielding reliable data for compliance monitoring purposes. Test results from validation of a modified method are used to demonstrate that the modified method produces results are equivalent to results produced by the EPA- designated approved method. Equivalency is established by demonstrating that the modified method produces results meet or exceed the QC acceptance criteria of the EPA-designated approved method. Verify that all items of the "Equivalency Checklist" are met: Askew Scientific Consulting LLC

What Is Required In the Equivalency Checklist?? Concentrations of calibration standards. Document the range of the concentrations of material used to establish the relationship between response of the measurement system and analyte concentration. %RSD or correlation coefficient of calibration regression. Performance range tested with units. Sample(s) used in initial demonstration have the recommended preservative, where applicable. Sample(s) used in initial demonstration met recommended holding times, where applicable. Interferences. Document the qualitative identification criteria used. Performance evaluation studies performed for analytes of interest, where available. Askew Scientific Consulting LLC

Latest study sponsor or title Latest study number. Analysis of external reference material Results of analyses on reference material from a source different from that used to prepare the calibration standards, if applicable. Sources of external reference material, if applicable. Surrogates used, if applicable. Concentrations of surrogates, if applicable. Recoveries of surrogates appropriate to the proposed use, if applicable. Sample preparation. Clean-up procedures. Method blank result. Matrix (reagent water, drinking water, effluent) Matrix spikes. Spiking system, appropriate to the method and application. Askew Scientific Consulting LLC

Source of spiking material. Number of replicate spikes Spike concentrations (with units corresponding to the final sample concentration) and recoveries. Source of spiking material. Number of replicate spikes Initial demonstration of capability. Precision (analyte by analyte) Duplicates. Bias (analyte by analyte). Detection limit (with units; analyte by analyte). Confirmation of detection limit, if applicable. Quantitation limit (with units; analyte by analyte) Minimum level (ML), practical quantitation level (PQL) or limit of quantitation (LOQ). Qualitative confirmation. Askew Scientific Consulting LLC

So Where Do You Find These?? My Auditor is Breathing Down My Neck!! Askew Scientific Consulting LLC

Product Insert or Instrument Manual Askew Scientific Consulting LLC

What Won’t You Find in a Product Insert or Instrument Manual %RSD or correlation coefficient of calibration regression. Performance evaluation studies performed for analytes of interest, where available. Analysis of external reference material Results of analyses on reference material from a source different from that used to prepare the calibration standards, if applicable. Sources of external reference material, if applicable. Askew Scientific Consulting LLC

Matrix (reagent water, drinking water, effluent) Matrix spikes. Method blank result. Matrix (reagent water, drinking water, effluent) Matrix spikes. Spiking system, appropriate to the method and application. Spike concentrations (with units corresponding to the final sample concentration) and recoveries. Source of spiking material. Askew Scientific Consulting LLC

Number of replicate spikes Initial demonstration of capability. Duplicates. Bias (analyte by analyte). Detection limit (with units; analyte by analyte). Confirmation of detection limit, if applicable. Askew Scientific Consulting LLC

NOW, What Do I Do ??? Auditor Has The Checklist Out!!! Askew Scientific Consulting LLC

Thing You Should Have Done Require Supplier to Provide: Equivalency Report that Answers ALL requirements in 40 CFR 136.6 and Richard Redding’s Memo!! https://www.epa.gov/sites/production/files/2015- 08/documents/cwa-method-flexibility_memo_11-20-2007.pdf Method in EPA Format Product Insert Does Not Do This!!!! Additional Nice Items to Have: Check List for Laboratory Management/QC Staff Check List for Laboratory Staff Askew Scientific Consulting LLC

Laboratory Staff Checklist Example Table 1: Laboratory Method Equivalency Checklist Item from Reding Memo Check Off (Yes/No) Have a detailed Standard Operating Procedure (SOP) available. (Guidance provided in Spectroquant® method)   Performing and document an initial demonstration of capability. (Required in Spectroquant® method) Verify the modified method by analyzing and documenting 3-7 representative effluents (QC in the Spectroquant® method meets this requirement as per 40 CFR part 136.6(b)(2)(i)(A)). The facility/lab is to show they can get the modified method to work and that it gets comparable results for their effluent. (QC in the Spectroquant® method meets this requirement as per 40 CFR part 136.6(b)(2)(i)(A)) A demonstration of calibration linearity or use of a calibration curve. (required in Spectroquant® method) Periodic calibration verification (Required in Spectroquant® method) An ongoing demonstration of performance (ongoing precision and recovery (OPR) and a blank with each sample batch (Required in Spectroquant® method) A demonstration of the method detection limit (MDL) (Required in Spectroquant® method) Matrix spike and matrix spike duplicate for each discharge the first time that the sample of the discharge is analyzed and at a frequency of 5% thereafter (Required in Spectroquant® method) Meeting the quality control (QC) specifications of the method. (See Spectroquant® method) Keep on hand the modified method manufacturer's supporting data available for review when the manufacturer has developed the method modification. Askew Scientific Consulting LLC

Examples MilliporeSigma http://www.emdmillipore.com/USEPA Environmental Express http://www.envexp.com/products/1- Wet_Chemistry/PW- Solids_Testing/TDSSW- StableWeigh_for_TDS Askew Scientific Consulting LLC

Questions ?????? Askew Scientific Consulting LLC