Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist

Slides:



Advertisements
Similar presentations
Radiation biology and protection in dental radiology
Advertisements

Technique Guidance Systems
RADIATION PROTECTION PRINCIPLES.  Prevent the occurrence of the non-stochastic effect by restricting doses to individuals below the relevant thresholds.
FPS HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENTFPS PUBLIC HEALTH, FOOD CHAIN SAFETY AND ENVIRONMENT Medical Imaging Federal initiative Dr Aldo Perissino.
Radiation Safety Training for Fluoroscopy in Research Radiation Safety Office Indiana University Purdue University Indianapolis and Associated Facilities.
Veterinary Radiation Safety 4 Students Radiation Safety MA Law requires that persons who perform diagnostic radiology procedures on animal patients be.
IAEA International Atomic Energy Agency Responsibility for Radiation Safety Day 8 – Lecture 4.
Radiation Occupational exposures and protection A. H. Mehrparvar, MD Occupational Medicine department Yazd University of Medical Sciences.
Radiation Sources in medicine diagnostic Radiology
TIMERS.
IAEA International Atomic Energy Agency Regulations Part I: Role and Structure of Regulations Day 8 – Lecture 5(1)
Maximum Permissible Dose (MPD)
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
IAEA International Atomic Energy Agency Interventional Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(3)
The ICRP System of Protection Applied to Medical Exposures
International Atomic Energy Agency Medical exposure in radiology: Justification Module VIII.2: Justification of medical exposures.
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
Prime Responsibility for Radiation Safety
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Basic radiation protection & radiobiology
Preparing Variable kVp Technique Charts By Prof. Stelmark.
Part 2.
Radiographic Quality Visibility and Sharpness
Radiation Sources in medicine diagnostic Radiology
Radiographic Equipment
IAEA International Atomic Energy Agency Regulations Part III: Radiation Protection Performance Requirements Day 8 – Lecture 5(3)
Part No...., Module No....Lesson No
Diagnostic reference levels in Medical Imaging. Concept and practice
Radiation Sources in medicine diagnostic Radiology
Week 2 :Radiation Protection
VIII.3. Optimization of Protection for Medical Exposures in Nuclear Medicine. 4. Guidance levels Postgraduate Educational Course in Radiation Protection.
4/2003 Rev 2 IV.1.3 – slide 1 of 46 Part IVPrinciples of Radiation Protection and the International Framework Module 1Conceptual Framework Session 3Justification,
Radiation Safety Regulations
FLUORO/IR Radiography By Dr. Wambani, J.S. Chief Radiologist Kenyatta National Hospital IAEA RADIOGRAPHERS TRAINING 11 TH -16 TH July 2011.ACCRA,GHANA.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
IAEA International Atomic Energy Agency Radiation protection of the public IAEA Regional Training Course on Radiation Protection of patients for Radiographers,
IAEA International Atomic Energy Agency Fluoroscopy Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(2)
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Need for a Regulatory program.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 12.1 : Shielding and X-ray room design Practical.
BY GAMINI SENANAYAKE.  Legislation applicable to staff and public Ionising radiation regulations 1999  Legislation applicable to patients – Ionising.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
HEALTH CARE STATISTICS AND RESEARCH HEPR 410
RADIATION PROTECTION 04/12/2016.
EVERYTHING YOU WANTED TO KNOW BUT WERE AFRAID TO ASK!!!!
Impact of Obesity on Medical Imaging and Image-Guided Intervention
Optimisation of Patient Protection for Radiography
X-RAY PRODUCTION AND EXPOSURE FACTORS
Resident Physics Lectures
RADIATION PROTECTION Salman Albeshan.
Radiation protection for paediatric patients
Do not adjust your set.
The pathological effects of ionising radiation
Principles of Radiation Protection
General Radiography By Dr. Wambani, J.S. Chief Radiologist
Radiation Protection in Dental Radiology
Developing a technique Chart Chapter 9
Resident Physics Lectures
Pediatric Fluoroscopy
Mobile Fluoroscopy Based on:
Resident Physics Lectures (Year 1)
Pediatric Fluoroscopy
Radiation Protection in Fluoroscopy
Pediatric Fluoroscopy
Conducting the Fluoroscopic Examination & Basic Operational Procedures
Occupational Radiation Dose Management
Ethical Considerations for Pediatric Clinical Investigations
Presentation transcript:

Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist Kenyatta National Hospital IAEA RADIOGRAPHERS TRAINING 11TH-16TH July 2011 .ACCRA ,GHANA

Objective To become familiar with the specific devices used in pediatric radiology To know the specific radiation risk concerning children

Contents Description of specific equipment and auxiliary devices used for children Knowledge of appropriate exposure factors in pediatrics Equipment malfunction affecting radiation protection Criteria of acceptability and quality control

Pediatric Equipment Because of their longer life expectancy and their greater sensitivity to radiation, the risk of late radiation effects is greater in children than in adults. In view of this increased radiation risk in younger age, the radiological examination of children (0-15 years) merits special consideration and specific recommendations for pediatric equipment and procedures. Pediatric radiology is a recognised sub-speciality within diagnostic radiology and specific education and training should be obligatory for pediatric radiology practitioners.

Pediatric Equipment (cont) Special Equipment for Pediatric Examinations

Pediatric Equipment (cont)

Pediatric Equipment (cont)

Pediatric Equipment (cont) The basic criteria for x-ray equipment used in pediatric radiology are the same as for general purpose equipment. However, additional performance and design requirements are necessary because of the small size of the patients and the special conditions required for many examinations (such as dealing with movement of a child). These include:- very short, accurate and reproducible exposure times; collimators adjustable to dimensions that may be smaller than some simple general purpose x-ray equipment may provide. The design and appearance of x-ray rooms are also important to improve the co-operation of children.

Pediatric Equipment (cont) Consequently: powerful generators are necessary for the very short time exposure times required (only 12-pulse or medium-high frequency generators should be used to ensure suitable accuracy and reproducibility); where mobile x-ray equipment must be used (although not advisable), medium or high frequency generators are preferred; low x-ray tube voltages should be avoided whenever practicable. Hgher x-ray tube voltages and appropriate additional filtration are recommended;

Pediatric Equipment (cont) a nominal focal spot size of between 0.6 mm and 1.3 mm is desirable; the x-ray beam must be carefully restricted to the area of clinical interest by the use of accurate light beam collimation; additional protective shielding must be adapted to children and available in a range of sizes; low attenuation materials between the x-ray tube focus and the image receptor (e.g. table top, cassette, anti-scatter grid) will contribute to dose reduction;

Pediatric Equipment (cont) In infants and younger children, the use of an anti-scatter grid may not always be necessary. Therefore, anti-scatter grids in pediatric equipment must be easily removed by the operator. Some automatic exposure control (AEC) systems may not function satisfactorily due to the wide range of body thickness and proportion in children. Specially designed pediatric AECs have a small mobile detector for use behind a lead-free cassette.

Pediatric Equipment (cont) Careful manual selection of exposure factors may result in lower radiation doses. The selection of faster intensifying screen-film systems, and image intensifiers with high conversion factors, will result in lower radiation doses. Proper patient positioning and immobilisation are essential: immobilisation devices must be easy to use without stressing the patient.

Malfunctions affecting radiation protection Basically the same as for general x-ray systems but the tests performed and the measuring instruments used shall be adapted to pediatric equipment. Quality control programs are especially important in pediatric radiology services.

Protection principles Justification Optimisation (ALARA) Dose Reference Levels (DRLs) Dose limits

Justification Risks v/s Benefits No practice involving exposures to radiation should be adopted unless it produces sufficient benefit to the exposed individuals or to society to offset the radiation detriment it causes

Optimisation (ALARA) -1 In relation to any particular source within a practice, the magnitude of individual doses, the number of people exposed, and the likelihood of incurring exposures where these are not certain to be received should all be kept As Low As Reasonably Achievable, economic and social factors being taken into account.

Optimisation (ALARA) -2 This procedure should be constrained by restrictions on the doses to individuals (dose constraints), or the risk to individuals in the case of potential exposures (risk constraints), so as to limit the inequity likely to result from the inherent economic and social judgement.

The Dose Limits Continuous exposure at or near the dose limit is considered unacceptable The dose limit should form only part of the system of protection within the As Low As Reasonably Achievable (ALARA) framework

The Dose Limits Natural background exposure ~ 2 to 2.5 mSv per annum is expressly excluded from occupational exposure. There are two exceptions: Air crew uranium mining Medical exposure is expressly excluded There are no dose limits for medical exposures BUT!

THANKS!