“minimum-ionisation” peak

Slides:



Advertisements
Similar presentations
Study of plastic scintillators for fast neutron measurements
Advertisements

Electromagnetic shower in the AHCAL selection criteria data / MonteCarlo comparison of: handling linearity shower shapes CALICE collaboration meeting may.
Cosmic Rays with the LEP detectors Charles Timmermans University of Nijmegen.
GLAST LAT Project Calibration & Analysis Meeting - August 29, 2005 Benoît Lott Gamma-ray Large Area Space Telescope Response of the GLAST LAT Calorimeter.
Calorimeter GLAST Software Jan 2001 Naval Research Lab Washington DC J. Eric Grove 1 Calibration Software Needs For CAL BFEM J. Eric Grove Naval.
GLAST LAT Project Software vrvs meeting X. Chen 1 GLAST LAT Project Software vrvs meeting X. Chen 1 Analyses of Muon Calibration Data Xin Chen.
A.Chekhtman1 GLAST LAT ProjectCAL Recon rewriting meeting, May, 11, 2005 In what cases we need external position estimation ? Alexandre Chekhtman NRL/GMU.
NLC – The Next Linear Collider Project Colorado Univ. – Boulder, Jan., 2004 LCD-ALCPG Presentation at the ALCPG-SLAC Meeting Progress Report of Work at.
1 EMCal design MICE collaboration meeting Fermilab Rikard Sandström.
FMS review, Sep FPD/FMS: calibrations and offline reconstruction Measurements of inclusive  0 production Reconstruction algorithm - clustering.
Detectors of charged particles and ions 1) Gas filled detectors a) Ionization chambers b) Proportional counters c) Multiwire chambers d) Time projection.
The Time-of-Flight system of the PAMELA experiment: in-flight performances. Rita Carbone INFN and University of Napoli RICAP ’07, Rome,
ICD Energy Calibration Andy White January 16, 2002.
The Design of Barrel Electromagnetic Calorimeter (BEMC) October Lu Jun-guang.
The CALICE Si-W ECAL - physics prototype 2012/Apr/25 Tamaki Yoshioka (Kyushu University) Roman Poschl (LAL Orsay)
Thomas Jefferson National Accelerator Facility Page 1 EC / PCAL ENERGY CALIBRATION Cole Smith UVA PCAL EC Outline Why 2 calorimeters? Requirements Using.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Calibration of the new Particle Identification Detector (PID) Tom Jude, Derek Glazier, Dan Watts.
Calibration of the CMS Electromagnetic Calorimeter with first LHC data
GLAST LAT Project Instrument Analysis Meeting August 6, 2004 David Smith w. Benoît Lott Muons in photodiodes1 MIPs in your Photodiodes David’s Instr. Ana.
1 Energy loss correction for a crystal calorimeter He Miao Institute of High Energy Physics Beijing, P.R.China.
January 21, 2007Suvadeep Bose / IndiaCMS - Santiniketan 1 Response of CMS Hadron Calorimeter to Electron Beams Suvadeep Bose EHEP, TIFR, Mumbai Outline:
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
Feb. 7, 2007First GLAST symposium1 Measuring the PSF and the energy resolution with the GLAST-LAT Calibration Unit Ph. Bruel on behalf of the beam test.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
ECAL PID1 Particle identification in ECAL Yuri Kharlov, Alexander Artamonov IHEP, Protvino CBM collaboration meeting
Degrader 58 Ni Beam Fragments Target FRS: FRagment Separator at GSI Darmstadt, Germany One single beam: 58 Ni, with energy varying between.1 and 1.7 GeV/nucleon.
Validation of EM Part of Geant4
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
1 GLAST LAT Project CalSoft Face-to-Face Meeting April 15 – 16, 2004 Benoît Lott GSI Analysis Status Degrader 58 Ni Beam Fragments Target EM miniCAL GSI’s.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
Feb. 3, 2007IFC meeting1 Beam test report Ph. Bruel on behalf of the beam test working group Gamma-ray Large Area Space Telescope.
V. Pozdnyakov Direct photon and photon-jet measurement capability of the ATLAS experiment at the LHC Valery Pozdnyakov (JINR, Dubna) on behalf of the HI.
Rita Carbone, RICAP 11, Roma 3 26/05/2011 Stand-alone low energy measurements of light nuclei from PAMELA Time-of-Flight system. Rita Carbone INFN Napoli.
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
CsI(Tl) Calorimeter and status of the E166 experiment E166 experiment CsI ( Tl) calorimeter construction. Test beam results vs. Geant4 simulation Schedules.
The PSD at Pb-Pb run PSD drawbacks at Ar beam
Beam test of Silicon-Tungsten Calorimeter Prototype
Experimental Method: 2 independent detectors on both sides of IP
Scintillation Detectors in High Energy Physics
“Performance test of a lead glass
Calibrating the CAL in flight: Galactic Cosmic Ray Calibration
Gamma-ray Large Area Space Telescope ACD Final Performance
CALICE scintillator HCAL
GLAST LAT tracker signal simulation and trigger timing study
Methods of Experimental Particle Physics
IHEP group Shashlyk activity towards TDR
Panagiotis Kokkas Univ. of Ioannina
Detection of muons at 150 GeV/c with a CMS Preshower Prototype
LHCf – CSN1 Trieste O. Adriani
Jin Huang Los Alamos National Lab
CMS ECAL Calibration and Test Beam Results
Detector Configuration for Simulation (i)
Chris Smith California Institute of Technology EPS Conference 2003
ScECAL+AHCAL+TCMT Combined Beam FNAL
Gamma-ray Large Area Space Telescope
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Kazuya Aoki For the PHENIX Collaborations. Kyoto Univ. / RIKEN
Rick Salcido Northern Illinois University For CALICE Collaboration
Imaging crystals with TKR
GLAST Large Area Telescope
Mini Tower Preliminary Results
Experimental Method: 2 independent detectors on both sides of IP
Analysis of GLAST Balloon Experiment Data
Presentation transcript:

“minimum-ionisation” peak In-orbit calibration Geomagnetic cutoff Use of the ionisation energy loss of cosmic-ray heavy ions C, N, O, Mg, Si, Fe CR energy spectrum } Eloss (E) “minimum-ionisation” peak minimum of ionisation

In-orbit calibration (2) CREME96 GEANT3 Simulated energy-loss distribution We need to: know the CsI light function L(E,Z), non-linear because of quenching effects; test algorithms for rejecting reaction events (variation of Eloss between adjacent layers).

Quenching effects in CsI High ionisation density  non-radiative decay channel (“activation-depletion” hypothesis, exciton destruction at activator sites, recombination...) Low energy: Birk’s formula L(E)E/(1+kB dE/dx) kB: quenching factor High energy: at a given dE/dx, E is higher for greater Z  more d electrons  less quenching Very scarce data at high energy! NaI(Tl) Salamon and Ahlen

Experimental setup at GSI Degrader 58Ni Beam Fragments Target One single beam: 58Ni from 100 to 1700 MeV/nucleon All fragments are produced simultaneously. The spectrometer offers great flexibility!

Why do a beam test at CERN? The LAT will cover the 20 MeV-300 GeV range, but the calibration at SLAC will be limited to 30 GeV. Wouldn’t be data at higher energies be useful? Although rare, photons with E>10 GeV will (arguably) be the most interesting, the 10 GeV-100 GeV domain has barely been explored. Only little ressource is needed to get these data. Our calorimeter is fairly thin: on-axis photons deposit only ~40% of their energy within the CAL: energy reconstruction for those is based on profile fitting. Surprisingly few data on shower profiles in the literature. CERN is a good place: GLAST is an “accepted experiment” at CERN. Different beams (secondary+tertiary) are available with a great flexibility: electrons, pions,muons with energies up to 150 (300) GeV, down to 10 GeV CERN shut down in 2005. Beam available for GLAST in 2004 (?)

Experimental Method Duration : 1 week of beam time on the H6 beam line (Aug 7-13) Detectors: 48 CDEs (AMCRYS): 8 Bordeaux, 15 CEA, 25 Kalmar+CEA arranged in 8 layers of 6 15 CDEs (BTEM) from NRL arranged in 3 layers of 5 positioned on a moving table + rotating table (48) Electronics: 222 channels preamp + 2 sets of shaping amplifiers low-gain “x1”, high-gain “x20” commercial VME ADCs (CAEN 785) Localization: 2 X-Y Silicon chambers (Trieste) Trigger: 2x2x0.2 cm3 plastic scintillator located 6 m in front of the detector Beams: electrons at 10-20-50-80-120-150 GeV, 20 GeV muons, 20 GeV pions Count rate: 100 Hz “Converter”: 15x15 cm2 Pb sheets of various thicknesses (0-16 X0, 1.3 X0) People: Bordeaux: 7, Kalmar: 3, CEA: 2, Trieste:2

Setup This is the outline of the talk: I will briefly remind you of the design of the LAT calorimeter, give its current status, show a few slides on the construction Process, the present the status of the flight manufacturing. I then present the milestones along the way towards the delivery of the subsystem. Then I talk about the identified threats to maintaining schedule and cost.

Energy Calibration All we have for absolute calibration are muons E-deposits. Can we use the muon data alone (Edep~12 MeV) to establish the calibration up to tens of GeV? Procedure: Muons in Big Diodes (BD) corrected for attenuation* Conversion Slope for BDs with high-gain amplifiers Pulser: relative gains between low- and high-gain amplifiers Conversion slopes for Big Diodes with low-gain amplifiers Small-diode vs Big-diode correlation using beam data: Conversion slopes for Small Diodes *attenuation coefficients: Left/Right dependence on position

Energy calibration with a 20 GeV muon beam 2002 experiment data MC GEANT3 high-gain amplifiers

Longitudinal shower profiles 50 GeV 1.3 X0 80 GeV 1.3 X0 120 GeV 0 X0 120 GeV 4 X0 120 GeV 8 X0

Last layer correlation data GEANT4 100 evts….

Light collection asymmetry

Position measurement