GLADSTONE 1800mm Steel culvert rehabilitation

Slides:



Advertisements
Similar presentations
Sample Problem 4.2 SOLUTION:
Advertisements

Neptune Research Inc. Introduction For more than 25 years, Neptune Research Inc. has focused its strategic research initiatives on the development, manufacturing.
6-1 Chapter 6 Overview b Four major alloy groups most common: Aluminum, magnesium, zinc and ZA Aluminum, magnesium, zinc and ZA b These alloys have a range.
Manufacturing Technology
Sample Problem 4.2 SOLUTION:
Sample Problem 4.2 SOLUTION:
Polymers in Civil Engineering “Poly” “meros” = many parts Monomer = non-linked “mer” material Polymers = long continuous chain molecules formed from repeated.
Fluoropolymers Teflon ® / Tefzel ® are DuPont registered trademarks FH 8 Oct 02 / page 1 TYPICAL PROPERTIES MOLECULAR WEIGHT COMONOMER CONTENT MELTING.
Composites Use In Heavy Truck Ed Zenk Ed Zenk Composite Materials Engineer, International Truck & Engine Corp. Composite Materials Engineer, International.
1Furmanite Confidential - 1/9/04 Motor and Pump Base Foundational Repair.
Structural Engineering
Mechanical Properties
*Who We Are* *What We Do* *Why You Should Use CMP Repair* *What Can You Expect*
Engineering Practicum Baltimore Polytechnic Institute M. Scott A single iron rod, radius R, has a critical buckling load B and a tensile fracture force.
Aggregates for Concrete
TEAM: FIBREX Waterproofing Coating. Introduction  The ASTM Standard defines it is a treatment of a surface to prevent the passage of water under hydrostatic.
Mechanical Engineering Department Advanced Composites Dr. Talal Mandourah 1 Lecture 7 & 8 Comparison of Fibers.
Strength Resistance to failure. Strength Types 1.Compressive strength 2.Tensile strength 3.Flexural strength 4.Shear strength 5.Torsional strength 6.Bond.
3. Stresses in Machine Elements Lecture Number – 3.1 Prof. Dr. C. S. Pathak Department of Mechanical Engineering Sinhgad College of Engineering, Pune Strength.
Mix design of fiber reinforced concretes Exercise 9.
Presentation for project in Israel
1 Tribological performance of PEEK composites under the lubrication of ILs Yijun Shi a, Jian Wu b, Xiaohua Lu b a Division of Machine Elements, Luleå University.
Machine Design I (MCE-C 203) Mechatronics Dept., Faculty of Engineering, Fayoum University Dr. Ahmed Salah Abou Taleb Lecturer, Mechanical Engineering.
A cast-iron machine part is acted upon by a 3 kN-m couple
Chapter 4 - Flexure King Saud University University Civil Engineering Department Reinforced Concrete Design Prof. Dr. Mohammad Jamal Al-Shannag.
Rigid Foam Anelise Williamson MEEN Prime Flex 985 Urethane Resin Lightweight, rigid foam Two components.
Properties of Concrete Design and Control of Concrete Mixtures – Chapter 9.
Dr Kafeel Ahmed Strength Resistance to failure. Dr Kafeel Ahmed Strength Types 1.Compressive strength 2.Tensile strength 3.Flexural strength 4.Shear strength.
Epoxy (Polyepoxide) Gerardo De Leon MEEN Epoxy ( Polyepoxide)
Aluminum Alloy 6061 – Composition, Properties, Temper and Applications of 6061 Aluminum.
Epoxy Infusion System – Hardener SIN B17 Polynt’s SIN B17 is the world’s first Epoxy resin hardener based on anhydride chemistrythat has been specially.
SOIL MECHANICS AND FOUNDATION ENGINEERING-III (CE 434)
What is a Fiber…? Small piece of reinforcing material possessing certain characteristic properties. Can be circular or flat. Parameter used to describe.
New High Performance Resin for Thermoplastic Liners
CRACKS IN BUILDINGS: Some Remedial Measures
Lightweight Concrete Lightweight Aggregate Concrete
Use of Modern Retrofitting Techniques in Udaipur Station Building
Polymers in Civil Engineering
4708 Technical Data Sheet °F ( °C) High Tg Epoxy Resin System
ACI Fall 2016 Convention-Philadelphia
Table 4. Mechanical properties of repair and substrate concrete
DEPARTMENT OF MECHANICAL AND MANUFACTURING ENGINEERING
REPAIR OF TIMBER BEAMS USING CFRP SHEETS
GOVERMENT ENGINEERING COLLEGE BHUJ (CIVIL ENGINEERING)
selection of materials, stresses
Implant: مادة سنية / د . زينة ثاني اسنان موصل 12 / 4 / 2016
Sample Problem 4.2 SOLUTION:
Dan Meng, C.K. Lee, Y.X. Zhang*
Technical Services Manager
Pure Bending.
Strength of Materials University of Technology Second Class
3. Stresses in Machine Elements
Plain & Reinforced Concrete-1 CE3601
Variables Investigated :
بسم الله الرحمن الرحيم.
Structure I Course Code: ARCH 208 Dr. Aeid A. Abdulrazeg
Sample Problem 4.2 SOLUTION:
Tutorial in Mechanical Properties
Centroid 1st Moment of area 2nd Moment of area Section Modulus
New High Performance Resin for Thermoplastic Liners
Mechanically Pre-Stressed Glass Elements
LECTURE-I Introduction Some important definitions
FIBER REINFORCED CONCRETE
Elastic & Plastic behavior of Materials
Willamette Valley Company
Mechanical Properties Of Metals - I
PANDA Forward Spectrometer Calorimeter (Shashlyk) status and plans
Tutorial.
Mechanical Property 기계적 성질
Presentation transcript:

GLADSTONE 1800mm Steel culvert rehabilitation

Callemondah 4680 QLD

History of the project Rainfall January 2011

Flooding 2011

Problems

Idea Repair the ground Repair the pipe Trenchless

Proposed Solution Tender Engineer and prove methodology Rehabilitate the ground Rehabilitate the culvert Minimal disruption to public and rate payers Culvert remain in service. No excavation Needed to achieve equivalent to class 2 RC for Load requirements.

Newcastle University Composite only 150MPa 26.5kN/m 3. Finite Element Predictions The Table below shows the results of the finite element analysis work. Pipe Configuration Limiting Stress (MPa) Uniformly Distributed Load kN/m) Composite only 150MPa 26.5kN/m Composite only with support 150MPa 112kN/m Composite and steel 350MPa in the steel 30kN/m Composite and steel with support 350MPa in the steel 128kN/m

Uretek Injection Ground Engineering Mainmark have injecting Urethane for 25yrs Used to fill voiding and stabilise the ground the ground and foundation of the culvert.

ENCAP6™ Advanced Structural Relining Technologies Product Features Exceptional abrasion resistance Excellent chemical resistance High compressive strength Long-life hydrolytic stability Compliments our existing suite of advanced engineering solutions A liner that chemically and mechanically bonds with concrete and steel. Sprayable

ENCAP6™ Physical Properties Properties at 25°C Method Units Encap6 with laminate Encap6 without laminate Flexural Strength ASTM D790 MPa 280 135 Flexural Modulus GPa 14 6 Flexural Elongation @ Break % 4.5 Tensile Strength ASTM D638 150 67 Tensile Modulus 6.2 Density ASTM D792 g/ml 1.6 1.3 Viscosity ASTM D2196 cP 4,000 6,000 Thix Index n/a 5.0 5.6 Glass Content Formula 50 12.5 Styrene Content 45% Barcol Hardness, Ultimate (GYZJ-935 scale) ASTM D2583   60 38 HDT ASTM D648 °C 105

Challengers Cleaning Rain Hot weather with resin Bypass pumping

Job Done Job completed on time and Budget

2013 Gladstone received 1100mm in 3x days

Take home message Don’t just reline the internal surface Treat, Repair and Fill the foundation