LAB #6 Volume Flow Rate and Centerline Speed in a Tube Wind Tunnel

Slides:



Advertisements
Similar presentations
S. Ghosh, M. Muste, M. Marquardt, F. Stern
Advertisements

ME 322: Instrumentation Lecture 15
Density, ρ= mass/unitvolume –Slugs/ft3;kg/m3
Study on Wave calculation of an air cushion surge chamber
Experiment #5 Momentum Deficit Behind a Cylinder
Pannon Power – Biomass Power Plant project combustion flow measurement using a diff.pressure Pitot tube and a unique calibration method Manninger Gusztav.
ME 322: Instrumentation Lecture 32 April 10, 2015 Professor Miles Greiner.
CBE 465 4/14/2017 Heuristics “Rules of Thumb”.
Fluid in Motion.
ME 388 – Applied Instrumentation Laboratory Wind Tunnel Lab
ME 388 – Applied Instrumentation Laboratory Centrifugal Pump Lab.
CHE/ME 109 Heat Transfer in Electronics LECTURE 18 – FLOW IN TUBES.
Bernoulli ’ s Equation. Outline The Energy Balance for a Steady Incompressible Flow The Friction Heating Term Bernoulli ’ s Equation The Head Form Diffusers.
 Purpose  Test design  Measurement system and Procedures  Uncertainty Analysis.
Flow Sensors.
Notes Reminder: please turn in HW, pick up new one Reminder: First Exam next Friday, 1:55-3:50pm, Jordan Hall lab room – Will cover Gravity, Fluids (Ch.13,
LIFT.
Hydrodynamics.
Fluid Mechanics 05.
CHE/ME 109 Heat Transfer in Electronics
ME 322: Instrumentation Lecture 16 February 25, 2015 Professor Miles Greiner Lab 6 calculations (Excel demo)
Copyright: Prof S.A. Kinnas
Dimensional analysis Drag force on sphere depends on: The velocity U
Venturi Meter By Alex Turner & Mick Lock. What is it? A pipe that has a cone that narrows and then gradually returns to the original diameter of the pipe.
Measurement of Pressure Distribution and Lift for an Airfoil  Purpose  Test design  Measurement system and Procedures  Instrumentation  Data reduction.
Add To Table of Contents:
 Purpose  Test design  Measurement system and Procedures  Uncertainty Analysis.
ME 322: Instrumentation Lecture 11 February 11, 2015 Professor Miles Greiner Pitot probe operation, non-linear transfer function, fluid density, uncertainty,
Copyright: Prof S.A. Kinnas
Drag and Lift E80 Fluid Measurements Spring 2009.
ME 322: Instrumentation Lecture 13: Exam Review February 18, 2015 Professor Miles Greiner.
Measurement of Pressure Distribution and Lift for an Airfoil  Purpose  Test design  Measurement system and Procedures  Uncertainty Analysis  Data.
MECH 322 Instrumentation Lab 5 Elastic Modulus of an Aluminum Beam Performed: February 9, 2004 Sinan Ozcan: I believe I performed 50% of the work for this.
Aerodynamics By. NBueckert. What is Aerodynamics  Aerodynamics is making an object affect the air flow around it  It also is a type of Fluid Dynamics.
Experimental Determination of Molecular Speeds Stephen Luzader Frostburg State University Frostburg, MD.
ME 322 LAB 7 Computer Data Acquisition System for Steady Thermocouple Signals Performed : 02/13/2004 Sinan Ozcan : I believe I performed 50% of this lab.
MECH 322 Instrumentation Lab 6 Fluid Speed and Volume Flow Rate Performed: February 27, 2007 Group 0 Miles Greiner Lab Instructors: Mithun Gudipati, Venkata.
ME 391 Instrumentation LAB #6 Volume Flow Rate and Centerline Speed in a Tube Wind Tunnel Performed: 03/05/2004 Soma: I believe I performed 50% of this.
Date of download: 5/28/2016 Copyright © ASME. All rights reserved. From: Forced Convection Heat Transfer in Spray Formed Copper and Nickel Foam Heat Exchanger.
Introduction to Fluid Mechanics
Physical Modeling of the Atmospheric Boundary Layer in the UNH Flow Physics Facility Stephanie Gilooly and Gregory Taylor-Power Advisors: Dr. Joseph Klewicki,
SUGGESTED MINIMUM KNOWLEDGE OF FLUID MECHANICS AND FOR FE EXAM
MECH 391 Instrumentation Lab 11 Unsteady Velocity in a Karman Vortex Street Performed: 04/07/05 Sinan Ozcan: I believe I performed 50% of this lab Participation.
UNDERSTANDING DIFFERENT
6.5 Recommended Velocity Of Flow In Pipe And Tubing.
ME 322: Instrumentation Lecture 41
Process Variables, Elements and Instruments – Flow - Agenda
Figure 10.1 Flow in a duct with area change.
alternate form of Euler’s equation
General Information Lab -3 Bernoulli Equation
ME 322: Instrumentation Lecture 16
Aerodynamic Force Measurement
ME 391 LAB#5 Construction of a Computer Data Acquisition System for Measuring Steady Thermocouple Signals Performed : 02/13/2004 Sinan Ozcan : I believe.
ME 391 Instrumentation Lab 10 Calibration of a Hot-Film Anemometer
Air Volume Flow Rate and Centerline Velocity in a Tube Wind Tunnel
Airplane and Pilot Performance
Slides for ME 115 Laboratory
S. Ghosh, M. Muste, M. Marquardt, F. Stern
Comparison between Serrated & Notched Serrated Heat Exchanger Fin Performance Presented by NABILA RUBAIYA.
Chapter 6A: INFILTRATION BACKGROUND
Copyright: Prof S.A. Kinnas
Venturi Effect The Venturi effect is named after an Italian Physicist; Giovanni Venturi (1746–1822). The Venturi Effect is the reduction in fluid pressure.
Figure 19.6  Absolute temperatures at which various physical processes occur. Note that the scale is logarithmic. Fig. 19.6, p. 585.
Internal Flow: General Considerations
Instructions for Density Lab
 More Fluids  November 30,  More Fluids  November 30, 2010.
26. Flow Measurement and Safety Devices
Introduction to Fluid Mechanics
alternate form of Euler’s equation
Presentation transcript:

LAB #6 Volume Flow Rate and Centerline Speed in a Tube Wind Tunnel ME 391 Instrumentation LAB #6 Volume Flow Rate and Centerline Speed in a Tube Wind Tunnel Performed: 03/05/2004 Soma: I believe I performed 50% of this lab. (Participation: __/50) Sinan Ozcan: I believe I performed 50% of this lab.

Abstract The volumetric flow rate and centerline speed of air in a tube wind tunnel were measured for a range of blower speeds. As a consistency check, the centerline speed for each flow rate was compared to the centerlines speed based on slug and parabolic velocity profiles. The volume flow rate and centerline speed were determined by measuring the pressure from a venturi tube and a Pitot probe using pressure transmitters. The maximum volume flow rate was 0.077 + 0.002 m3/s. The measured centerline speed was bracketed by the values predicted for slug and parabolic velocity for all blower speeds.

Table 1 Atmospheric Conditions, Dimensions and Parameters for Experiment This table presents the atmospheric temperature and pressure during the experiment. It also presents the pipe and tube inner diameters and areas, and the venturi tube flow coefficient. The manufacture stated uncertainties of the pressure transmitters are also included.

Table 2 Measurement Readings and Calculated Values This table presents the transmitter current and pressure differences for the venturi tube, Pitot probe and gage pressure for different flow conditions. The uncertainty of the pressures is also included. The calculated tube absolute pressure, density, volume flow rate and centerline speed are also presented. The uncertainty of the volume flow rate and speed are based on the uncertainties of the venturi tube flow coefficient and pressure measurements.

Figure 1 Measured and Predicted Centerline Velocities Versus Volume Flow Rate The measured centerline velocity is between the values predicted for slug and parabolic velocity. The uncertainty in Q is more significant than that for S