The Luminosity Monitor

Slides:



Advertisements
Similar presentations
E status report Alexandre Camsonne Hall A Jefferson Laboratory Hall A collaboration meeting December 13 th 2007.
Advertisements

TIME 2005: TPC for the ILC 6 th Oct 2005 Matthias Enno Janssen, DESY 1 A Time Projection Chamber for the International Linear Collider R&D Studies Matthias.
NDVCS measurement with BoNuS RTPC M. Osipenko December 2, 2009, CLAS12 Central Detector Collaboration meeting.
H1 SILICON DETECTORS PRESENT STATUS By Wolfgang Lange, DESY Zeuthen.
Ozgur Ates Hampton University TREK Experiment “Tracking and Baseline Design” And OLYMPUS Experiment “Study of Systematics” 1.
Ozgur Ates Hampton University HUGS 2009-JLAB TREK Experiment “Tracking and Baseline Design”
GEM Detectors for AnDY Nilanga Liyanage University of Virginia 1 Outline GEM chamber concept Large area GEM chamber projects Proposed GEM configuration.
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
“THE OLYMPUS LUMINOSITY MONITORS” Ozgur Ates Hampton University 1  A Review of the MC Studies of the Lumi Monitors  Some GEM Reports from PREX at JLAB.
THE BRIEF HISTORY OF LuMo CONSTRUCTION FROM MIT TO HU OZGUR ATES HAMPTON UNIVERSITY OLYMPUS COLLABORATION MEETING APRIL 2011.
DESY PRC May 10, Beyond the One Photon Approximation in Lepton Scattering: A Definitive Experiment at DESY for J. Arrington (Argonne) D. Hasell,
Status of the Forward Elastic Scattering Luminosity Monitor Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA OLYMPUS.
“THE OLYMPUS LUMINOSITY MONITORS” Ozgur Ates Hampton University 1  OLYMPUS  Two Photon Exchange in Elastic Scattering  Principle of The Experiment 
Two-photon exchange: experimental tests Studying the QED expansion for elastic electron-proton scattering Motivation The Three Experiments Summary With.
OLYMPUS Luminosity Monitors
Detector Upgrades and Responsibilities Hampton University, Hampton, VA 23668, USA Workshop, DESY, March 31, 2008 Michael Kohl.
Luminosity Monitor Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA USA OLYMPUS Collaboration Meeting, DESY, July 17-18,
Monte-Carlo simulations and reconstruction for 12-degree ep-elastic Luminosity Monitor A.Kiselev OLYMPUS Collaboration Meeting DESY, Hamburg,
Richard MilnerDESY April 6, OLYMPUS Overview Motivation for the experiment Progress to date on the experiment The path forward.
Luminosity Monitor based on Forward Elastic Scattering Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA OLYMPUS Collaboration.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
HPS – ECal Detector - TECHNICAL PARAMETERS The experimental apparatus includes two main detectors: a silicon vertex tracker (SVT) for precise momentum.
DESY A proposal to definitively determine the contribution of multiple photon exchange in elastic lepton-nucleon scattering Hampton University.
High Precision Measurement of the Proton Charge Radius A. Gasparian NC A&T State University, Greensboro, NC Outline  Previous experiments and proton size.
Neutron Structure Functions and a Radial Time Projection Chamber The Structure of the Neutron The BoNuS Experiment at CLAS A New Proton Recoil Detector.
Rosen07 Two-Photon Exchange Status Update James Johnson Northwestern University & Argonne National Lab For the Rosen07 Collaboration.
Status Update of OLYMPUS and TREK Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA HU Group Meeting, Hampton University,
Yosuke Watanabe….. University of Tokyo, RIKEN A, KEK C, Development of a GEM tracker for E16 J-PARC 1 Thanks to ???????????
GEM chambers for SoLID Nilanga Liyanage University of Virginia.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
LHCb VErtex LOcator & Displaced Vertex Trigger
Neutral Current Deep Inelastic Scattering in ZEUS The HERA collider NC Deep Inelastic Scattering at HERA The ZEUS detector Neutral current cross section.
Latifa Elouadrhiri Jefferson Lab Hall B 12 GeV Upgrade Drift Chamber Review Jefferson Lab March 6- 8, 2007 CLAS12 Drift Chambers Simulation and Event Reconstruction.
Vina Punjabi Norfolk State University Hall A Collaboration Meeting June 10-11, 2010 GEp-V Experiment to Measure G Ep /G Mp.
Proton Charge Form Factor Measurement E. Cisbani INFN Rome – Sanità Group and Italian National Institute of Health 113/Oct/2011E. Cisbani / Proton FF.
1 Possibility to obtain a polarized hydrogen molecular target Dmitriy Toporkov Budker Institute of Nuclear Physics Novosibirsk, Russia XIV International.
Study of TGEMs and RETGEMs for the possible ALICE upgrade By Himank Anand and Isha Shukla (CERN summer students) Supervisor :Vladimir Peskov.
Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab F. Mammoliti, V. Bellini, M. Capogni, E. Cisbani, E. Jensen, P. Musico, F. Noto,
Optics, Tracking, and TOF Status/Update/Roadmap Xin Qian KRL Caltech.
GEp-III in Hall C Andrew Puckett, MIT On behalf of the Jefferson Lab Hall C GEp-III Collaboration April 15, 2008.
Inclusive Measurements of inelastic electron/positron scattering on unpolarized H and D targets at Lara De Nardo for the HERMES COLLABORATION.
HLAB meeting paper 2011/1/18 T.Gogami CLAS ( CEBAF Large Acceptance Spectrometer ) Clam shell is open.
L/T separation in the 3 He(e,e’p) reaction at parallel kinematics Freija Descamps Supervisors: Ron Gilman Eric Voutier Co-supervisor: Jean Mougey.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
INSTR L.Shekhtman 1 Triple-GEM detectors for KEDR tagging system V.M.Aulchenko, A.V.Bobrov,A.E.Bondar, L.I.Shekhtman, E.V.Usov, V.N.Zhilich,
SANE Collaboration ( E07-003) Anusha Liyanage Hampton University January 12, 2010 Measurement Of the Proton Form Factor Ratio at High Q 2 by Using The.
Status of OLYMPUS Hampton University, Hampton, VA Jefferson Laboratory, Newport News, VA HU Group Meeting, March 02, 2010 Michael Kohl.
1- Handling The Olympus GEMs at MIT-BATES between June 6th-August 8th Manufacturing The GEMs at HU-GEM LAB since Sep 2010 OZGUR ATES HAMPTON UNIVERSITY.
Comparison of GENIE with Garino Data Xin Qian BNL In collaboration with Steve Dytman 1.
Precision Measurement of G E p /G M p with BLAST Chris Crawford MIT Laboratory for Nuclear Science Thesis Committee Review Meeting 2003/12/4.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Antiproton-proton elastic scattering as a day-1 experiment at HESR
Experimental Method: 2 independent detectors on both sides of IP
First data from TOTEM experiment at LHC
LABORATORI NAZIONALI DI FRASCATI
A Precision Measurement of GEp/GMp with BLAST
Precision Measurement of η Radiative Decay Width via Primakoff Effect
Preparation of the CLAS12 First Experiment Status and Time-Line
1. Introduction Secondary Heavy charged particle (fragment) production
Status of Compton Analysis
A Precision Measurement of GEp/GMp with BLAST
Special Considerations for SIDIS
GEANT Simulations and Track Reconstruction
Experimental Method: 2 independent detectors on both sides of IP
GEp/GMp Group Meeting Chris Crawford May 12, 2005
Proposal for an Experiment: Photoproduction of Neutral Kaons on Deuterium Spokespersons: D. M. Manley (Kent State University) W. J. Briscoe (The George.
COMPTON SCATTERING IN FORWARD DIRECTION
25.5 days at 11.0 GeV & 6.5 days at 8.8 GeV = 32 days total
Gain measurements of Chromium GEM foils
TDIS mTPC update Nilanga Liyanage and Kondo Gnanvo UVa
Presentation transcript:

The Luminosity Monitor OLYMPUS Technical Review, DESY, September 15, 2009 The Luminosity Monitor Michael Kohl Hampton University, Hampton, VA 23668 Jefferson Laboratory, Newport News, VA 23606

Proposed Experiment Electrons/positrons (100mA) in multi-GeV storage ring DORIS at DESY, Hamburg, Germany Unpolarized internal hydrogen target (buffer system) 3x1015 at/cm2 @ 100 mA → L = 2x1033 / (cm2s) Large acceptance detector for e-p in coincidence BLAST detector from MIT-Bates available Measure ratio of positron-proton to electron-proton unpolarized elastic scattering to 1% stat.+sys. Redundant monitoring of (relative) luminosity ratios

Monitoring the Luminosities Pressure, temperature, flow, current measurements - limited in precision Moller/Bhabha scattering - 1.3 degrees for symmetric Moller setup - difficult to establish with clear view to target Small-angle elastic scattering - high count rate, no TPE at high epsilon / low Q2 - single-arm and in coincidence with recoil proton

Control of Systematics OLYMPUS: BLAST @ DORIS Luminosity monitors for lepton in coincidence with recoil proton detected in the opposite sector ~12o TOF Change BLAST polarity once a day Change between electrons and positrons regularly, randomly Left-right symmetry = redundancy

Control of Systematics Simple scheme to cancel detector efficiencies i = e+ or e- j= pos/neg polarity Geometric proton efficiency: Ratio in single polarity j Geometric lepton efficiency:

Control of Systematics Super ratio: Cycle of four states ij Repeat cycle N times -> reduction of systematics by √N Change between electrons and positrons once a day Change BLAST polarity regularly, randomly Left-right symmetry = redundancy Monte Carlo studies Further (small) corrections for individual acceptances Small effects by backgrounds and inefficiencies Effects from beam sizes and offsets (~1%/mm)

Triple Ratio Triple Super Ratio: Ratio of counts Ratio of luminosities Ratio of acceptances (phase space integrals) Cycle of four states ij Repeat cycle N times -> reduction of systematics by √N Separately determine three super ratios Blinding of final result until put together Left-right symmetry = redundancy

Luminosity Monitoring Analogous scheme applied to monitor luminosity Forward-angle (high-epsilon, low-Q) elastic scattering (se+ = se-) Measure Lij relatively (i.e. Nijfwd) and continuously to ~1%/hour At forward angle:

Forward Elastic Luminosity Monitor Forward-angle electron/positron telescopes with good angular and vertex resolution Coincidence with proton in opposite sector of main detector Single-arm tracks Two telescopes with 3 triple-GEM detectors, left-right symmetric High rate capability GEM technology MIT protoype: Telescope of 3 Triple GEM prototypes (10 x 10 cm2) using TechEtch foils F. Simon et al., NIM A598 (2009) 432

Luminosity Monitors: Telescopes Proposed version included in OLYMPUS TDR Sept. 2009 2 tGEM telescopes, 1.2msr, 12o, R=187/237/287cm, dR=50cm, 3 tracking planes Forward telescopes 12o TOF Geant4 simulation to optimize vertex resolution, solid angle and noise

Luminosity Monitors: Count rate Proposed version included in OLYMPUS TDR Sept. 2009 Two symmetric GEM telescopes at 12o Two-photon effect negligible at high-ε / low-Q2 Sub-percent (relative) luminosity measurement per hour at 2.0 GeV Same readout pitch as in MIT prototype (635 mm) Number of electronics channels per telescope: 3x(100+100)/0.635 ~= 1000 1.2 msr = 10 x 10 cm2 at ~290 cm distance (rearmost plane) Three GEM layers with ~0.1 mm resolution with ~50 cm gaps → Match vertex resolution (z) of ~ 0.1 – 1 cm at 12o with proton in BLAST

Providing GEM technology Collaboration HU-MIT TechEtch/MIT to provide tested GEM foils Test readout system Assembly of detectors and testing at HU / HUPTI / Jlab Establishing a GEM Lab at Hampton University Luminosity monitors for OLYMPUS (2009-2011) C0 cylindrical and C1 planar GEM trackers for Time Reversal Experiment with Kaons (TREK) at J-PARC (~2013) Augment 12 GeV program at Jlab (~2014) Funding: Secured NSF Nuclear Physics/ARRA basic research grant ($405k) postdoc + travel; 1 graduate student supported by HU NSF group Requested $125k within NSF MRI-R2 for luminosity monitors

Luminosity Monitors: Cost estimate Proposed version included in OLYMPUS TDR Sept. 2009

Tasks & Timeline for LuMo Construction GEANT4 simulation Design parameters: location (solid angle), resolution Phase space integral(s) Effects of beam size and offsets New research building at HU to be ready for move-in in fall 2009 Expect MRI-R2 grant early next year, equipment funds Testing with beam possible at HUPTI or Jlab in fall 2010 Development of analysis software / integrate into OLYMPUS analysis

Backup slides

Control of Systematics Super ratio: Cycle of four states ij Repeat cycle many times Change between electrons and positrons once a day Change BLAST polarity regularly, randomly Left-right symmetry = redundancy Montecarlo studies Further (small) corrections for individual acceptances Effects by backgrounds and inefficiencies Effects from beam sizes and offsets

Cancellation of geometric efficiencies? Proton detection efficiencies Lepton detection efficiencies Does the “geometric efficiency” for coincidence of p-l really factorize? ε(pp,θp,pl,θl) =? κp(pp,θp) x κl(pl,θl) Does the coincidence of lepton and proton generate a correlation? What does “geometric efficiency” mean? p and l are kinematically correlated for the elastic process, as knowledge of just one variable (i.e. Q2) fully determines the elastic reaction kinematics The “detection efficiency” is independent of the kinematic correlation and hence factorizes for p and l, if detected at different locations in the detector (as is the case) But the “acceptance” is not! “Geometric efficiency” = “Detection efficiency” x “Acceptance”

Differential cross section Event counts: a(xk) = Acceptance function Bin-averaged differential cross section: Phase space integral Require acceptance simulation to determine phase space integral numerically!

Control of Systematics i = e+ or e- j= pos/neg polarity A = Acceptance function (phase space integral) MORE REALISTICALLY: Proton ”detection” efficiency: Ratio in single polarity j Lepton detection efficiency:

Triple ratio Triple Super Ratio: Ratio of counts Ratio of luminosities Ratio of acceptances (phase space integrals) Cycle of four states ij Repeat cycle many times Separately determine three super ratios Blinding of final result until put together Left-right symmetry = redundancy

Luminosity Monitoring MORE REALISTICALLY: Forward-angle (high-epsilon, low-Q) elastic scattering (se+ = se-) Measure Lij relatively (i.e. Nijfwd) and continuously to ~1%/hour At forward angle:

Control of Systematics MORE REALISTICALLY: Super ratio (“triple ratio”): Cycle of four states ij Repeat cycle N times -> reduction of systematics by √N Change between electrons and positrons every other day Change BLAST polarity regularly, randomly Left-right symmetry = redundancy Determine ratios of phase space integrals from Monte-Carlo simulation

Principle of GEM Detectors GEM = Gas Electron Multiplier introduced by F. Sauli in mid 90’s, F. Sauli et al., NIMA 386 (1997) 531 Copper layer-sandwiched kapton foil with chemically etched micro-hole pattern gas amplification in the hole

GEM foils 70 µm Typically 5mm Cu on 50mm kapton ~104 holes/cm2 140 µm Chemical etching R. De Oliveira (CERN-EST) TechEtch (MIT) 3M Corporation Laser drilling Tamagawa (RIKEN)

Multi-GEM Detectors GEMs can be cascaded for higher gain Gain of 104 needed for efficient MIP detection Double GEM Triple GEM C. Buettner et al., Nucl. Instr. and Meth. A 409(1998)79 S. Bachmann et al., Nucl. Instr. and Meth. A 443(1999)464

Luminosity Monitors: Telescopes Proposed version included in OLYMPUS proposal Sept. 2008 2 tGEM telescopes, 3.9 msr, 10o, R=160cm, dR=10cm, 3 tracking planes Forward telescopes 10o TOF

Luminosity Monitors: Count rate Proposed version included in OLYMPUS proposal Sept. 2008 Two symmetric GEM telescopes at 10o Two-photon effect negligible at high-ε / low-Q2 Sub-percent (relative) luminosity measurement per hour for all energies 3.9 msr = 10 x 10 cm2 at ~160 cm distance Three GEM layers with ~0.1 mm resolution with ~10 cm gaps → Vertex resolution (z) of ~1cm at 10o to match that of proton in BLAST Same readout pitch as in MIT prototype (635 mm) Number of electronics channels per telescope: 3x(100+100)/0.635 ~= 1000

Next steps and timeline Started to work on GEANT4 simulation (can use one graduate student of HU nuclear physics group) -> LuMo design parameters: location (solid angle), resolution Finalize design parameters and specifications until end of this year Start simulations of phase space integral(s) New research building at HU to be ready for move-in in fall 2009 Expect MRI-R2 grant early next year, equipment funds Purchase of parts within first year of grant Assembling/testing with sources and cosmics starting summer 2010 Testing with beam possible at HUPTI or Jlab in fall 2010 Implementation along with target in winter shutdown 2010/11 Commissioning with DORIS beam in spring 2011 Final implementation along with OLYMPUS in summer 2011 Development of analysis software / integrate into OLYMPUS analysis Production running begin and end of 2012