Charging Stations.

Slides:



Advertisements
Similar presentations
Trystar Generator Docking Stations & Portable Power Cable
Advertisements

SAE J1772™ Gery J. Kissel Engineering Specialist General Motors
The Vanjen Group • Manufacture's Representative – Power Generation/Oil & Gas • Covering TX, OK, LA, AK, in some cases NM and MS • Extensive.
Get connected with GE EV Infrastructure Solutions Charging Ahead with GE David P Wang EV Region Sales Leader – NA
Load Management System
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
Lineage Power - Total Efficiency TM Smart Grid A Telecom / Commercial consumer’s perspective Paul Smith – Technical Marketing Manager, Lineage Power
SYMAP-BC SYMAP-BC.
Technologies. About Us… EcoSpark Technologies is an enabler of energy infrastructure technology that specializes in the distribution, installation, and.
 A PHEV is a hybrid vehicle with batteries that can be recharged by connecting a plug to an external power source.  Features: › Internal Combustion.
| 1 © 2013 Universal Lighting Technologies ULT Marketing LED Product Capabilities.
Simple, accurate tenant sub-metering
Juice Bar EVSE Plug In BC (CCI Fund) Presentation Garage Juice Bar 750 Main Street, Suite 150 M Hartford, CT
The Vanjen Group • Manufacture's Representative – Power Generation/Oil & Gas • Covering TX, OK, LA, AK, in some cases NM and MS • Extensive.
Manufacture's Representative – Power Generation/Oil & Gas Covering TX, OK, LA, AK, in some cases NM and MS Extensive Power Gen Experience Extensive Docking.
PYROCON12 De-Ice controller User Operation Presentation 2013.
Make the most of your energy Make the most of your energy SM Add application photo in this area PowerLogic ® Branch Circuit Power Meter for data center.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
8/10/20151 THE BASICS OF INFRATECH HEATER CONTROLS.
eAutomation Enabler – Advantech Industrial NETworking
What to Expect in New Connectors New Connectors are Coming J (AC) CHADEMO (sometimes spelled CHΛdeMO) Protocol with the JARI Connector.
Generating and Using Electricity
TECH TALK - SAE J1772 and OpenEVSE Presented by: Christopher Howell
Presented by: Put your name/title here PRIMEX ® is a trademark of SJE-Rhombus ®
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. CENTERLINE 2100 Motor Control Center - SecureConnect™ September 1, 2011.
Page 1 LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Module Training Kit Rev 1.1 November 2006
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Survey of Smart Grid concepts and demonstrations Smart substation Ari Nikander.
ELECTRICAL WIRING WIRING BASICS Written by Bobby Joslin
The Northwest’s Authorized Distributors for Coulomb Technologies 1 Public Electric Vehicle Infrastructure Issues and Answers September 2010.
Charging Station for Electric cars with DC power
Avaya ePDU Andy McDonald August 2008
Poseidon 4002 Rack monitoring.
User Operation Presentation
SPD II 1 for LV Power (AC/DC)
Avaya VA Line-interactive UPS
C1300 advanced circular chart recorder
IP-based 8-port Switched Power Manager
Your Customers Name. EV Charging Proposal.
Technical Specification
V7 UPS Sales Training.
GROUND-FAULT GROUND-CHECK MONITOR
Trane Standby Generators
Product Description and Specifications
Mobile Cellular Communications System
De-Ice control devices

Overcurrent Protection— Fuses and Circuit Breakers
Technician Operation Presentation
Avaya ePDU Andy McDonald August 2008
The Safe Use of Electricity
4-Port IEEE 802.3at High Power over Ethernet Injector Hub
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Integrated gateway-server
PowerLogic™ offer for the basic metering market
Its strengths, your benefits
EPRI Truck & Bus Meeting SAE Medium and Heavy Duty Vehicle
Simple, accurate tenant sub-metering
What’s New In WatchGuard Wi-Fi Cloud v8.6
600 V HIGH VOLTAGE SOLUTION η μ.
Backup Power supply for Electrical substations Overview 01/2012
Presentation transcript:

Charging Stations

Products Wall Mount Bollard Pole Mount CT1000 Family - Level I CT2000 Family - Level II CT2100 Family - Level I & Level II

Level III Networked Fast Charging Station Products Level III Networked Fast Charging Station Level III networked fast charging stations for electric vehicles worldwide. The Level III charging stations will be capable of fully charging battery electric vehicles in half an hour. The Level III fast charging stations will be co-developed, distributed, marketed and supported by both companies. Designed in accordance with the TEPCO Level III specifications the charger will be qualified for use with several electric vehicle brands including the Nissan Leaf and the Mitsubishi i-Miev

CT1000 Family - Level I SPECIFICATIONS Radio Group 128 Charging Connection NEMA 5-20R receptacle AC Charging Power Output 1.9kW (120V at 16A) AC Power Input; Connections 120V 16A Single Phase; Line, Neutral, and Earth Recommended Service Panel Breaker 20A breaker on dedicated circuit Recommended Service Panel GFCI None. Do not provide GFCI at service panel as it can conflict with integral GFCI. Integral Hardware GFCI 5mA CCID with auto retry (15 min delay, 3 tries) Automatic Plug-Out Detection Programmable arm and trip current thresholds (patent pending) Power Measurement 1% @ 5 min interval; ANSI C12 capable (special order) Local Area Network 2.4GHz 802.15.4 dynamic mesh network Wide Area Network Commercial CDMA or GPRS cellular data network Network Communication Protocol TCP/IP Network Security HTTPS; 128-bit AES Encryption Maximum Charging Stations per 802.15.4 Radio Group 128 Each charging station must be within 150 feet of at least one other station Smart Card Reader ISO 15693 compliant Standby Power 5W typ. Outdoor Rated NEMA 3 per NEMA250-1997, IP44 per IEC 60529 Safety Compliance NRTL Tested; CSA C/US Certified per UL 2231-1, UL 2231-2, and UL 2202 NEC Article 625 Compliant Surge Protection 6kV @ 3,000A In geographic areas subject to frequent thunder storms supplemental surge protection at service panel is recommended EMI Compliance FCC Part 15 Class A Operating Temperature -30°C to +55°C Operating Humidity Up to 95% Voltage and Current Rating 120VAC @ 16A Terminal Block Temperature Rating 100°C Approximate Shipping Weights Bollard (CT1001) 50lb / 23kg Pole Mount (CT1002) 30lb / 14kg Wall Mount (CT1003) 33lb / 15kg

Specifications (preliminary) CT2000 Family - Level II Specifications (preliminary) CT2000 FAMILY CT2100 FAMILY Charging Connection Level II: SAE J1772™ EV connector on 18’ cable Level II: SAE J1772™ EV connector on 18’ cable Level I: NEMA 5-20R receptacle AC Charging Power Output Level II: 7.7kW (240VAC @ 32A) Level I: 1.9kW (120VAC @ 16A) Supports simultaneous Level I and Level II charging AC Power Input Level II: 32A; Line 1, Line 2, and Earth (no Neutral) connection, 208VAC or 240VAC operation Level I: 16A Line, Neutral, and Earth connection, 120VAC Recommended Service Panel Breaker Level II: Dual-pole 40A breaker on dedicated circuit Level II: Dual-pole 40A breaker on dedicated Level I: Single 20A breaker on dedicated circuit Recommended Service Panel GFCI None. Do not provide GFCI at panel Integral Hardware GFCI 20mA CCID with auto retry (15 min delay, 3 tries) Both Level I and Level II outputs 20mA CCID with auto retry (15 min delay, Automatic Plug-Out Detection Level II: Power terminated per SAE J1772™ specification CPNOS SMS or email notification Power Measurement 1% @ 5 min interval; ANSI C12 0.5% capable (special order) Both Level I and Level II outputs Local Area Network 2.4GHz 802.15.4 dynamic mesh network Wide Area Network Commercial CDMA or GPRS cellular data network Network Communication Protocol TCP/IP Network Security HTTPS; 128-bit AES Encryption Maximum Charging Stations per 802.15.4 Radio Group Smart Card Reader ISO 15693 compliant Standby Power 5W typ. Outdoor Rated NEMA 3 per NEMA250-1997, IP54 per IEC 60529 Safety Compliance UL Listed per UL 2231-1, UL 2231-2, and UL 2594. NEC Article 625 Compliant. Surge Protection 6kV @ 3,000A In geographic areas subject to frequent thunderstorms, supplemental surge protection at the service panel is recommended. EMI Compliance FCC Part 15 Class A Operating Temperature -30°C to +55°C ambient Operating Humidity Up to 95% non-condensing Terminal Block Temperature Rating 100°C Approximate Shipping Weights Bollard (CT2001) 58lbs Pole Mount (CT2002) 40lbs Wall Mount (CT2003) 40lbs Bollard (CT2101) 65lbs Pole Mount (CT2102) 49lbs Wall Mount (CT2103) 51lbs

CT2100 Family - Level I & Level II Specifications (preliminary) CT2000 FAMILY CT2100 FAMILY Charging Connection Level II: SAE J1772™ EV connector on 18’ cable Level II: SAE J1772™ EV connector on 18’ cable Level I: NEMA 5-20R receptacle AC Charging Power Output Level II: 7.7kW (240VAC @ 32A) Level I: 1.9kW (120VAC @ 16A) Supports simultaneous Level I and Level II charging AC Power Input Level II: 32A; Line 1, Line 2, and Earth (no Neutral) connection, 208VAC or 240VAC operation Level I: 16A Line, Neutral, and Earth connection, 120VAC Recommended Service Panel Breaker Level II: Dual-pole 40A breaker on dedicated circuit Level II: Dual-pole 40A breaker on dedicated Level I: Single 20A breaker on dedicated circuit Recommended Service Panel GFCI None. Do not provide GFCI at panel Integral Hardware GFCI 20mA CCID with auto retry (15 min delay, 3 tries) 20mA CCID with auto retry (15 min delay, Both Level I and Level II outputs Automatic Plug-Out Detection Level II: Power terminated per SAE J1772™ specification CPNOS SMS or email notification Power Measurement 1% @ 5 min interval; ANSI C12 0.5% capable (special order) Both Level I and Level II outputs Local Area Network 2.4GHz 802.15.4 dynamic mesh network Wide Area Network Commercial CDMA or GPRS cellular data network Network Communication Protocol TCP/IP Network Security HTTPS; 128-bit AES Encryption Maximum Charging Stations per 802.15.4 Radio Group Smart Card Reader ISO 15693 compliant Standby Power 5W typ. Outdoor Rated NEMA 3 per NEMA250-1997, IP54 per IEC 60529 Safety Compliance UL Listed per UL 2231-1, UL 2231-2, and UL 2594. NEC Article 625 Compliant. Surge Protection 6kV @ 3,000A In geographic areas subject to frequent thunderstorms, supplemental surge protection at the service panel is recommended. EMI Compliance FCC Part 15 Class A Operating Temperature -30°C to +55°C ambient Operating Humidity Up to 95% non-condensing Terminal Block Temperature Rating 100°C Approximate Shipping Weights Bollard (CT2001) 58lbs Pole Mount (CT2002) 40lbs Wall Mount (CT2003) 40lbs Bollard (CT2101) 65lbs Pole Mount (CT2102) 49lbs Wall Mount (CT2103) 51lbs

Features Smart Card: Open, standards-based RFID provides authorized network access control preventing electricity theft, enhancing safety and minimizing liability. Automatic SMS text and/or email notification: Warns drivers of events and issues, such as when charging is complete or interrupted. High Availability: Real-time remote control monitoring and management features minimize station downtime and enable remote start/stop of charging sessions. 24/7 Charge Point Network customer support: Available via toll-free number. Advanced safety features (Level I): Power is not energized until the driver is authorized, plug is fully inserted, and the door is relocked. Locking door (Level I): Retains the charging cord to prevent theft, and includes auto unlock in case of power outage. Auto plug-out detect (Level I): Automatically detects if charging cord has been un-plugged at the vehicle, de-energizes outlet and optionally notifies driver (patent pending). GFCI: Integral hardware ground-fault protection circuitry with auto retry minimizes nuisance GFCI trips. Fast over-current detect at charging station: Minimizes nuisance breaker trips at service panel. Bi-directional, utility-grade power measurement: Integral power metering circuitry provides accurate measurement of energy delivered for charging and allows calculation of Green House Gas savings. Wide Area Network Connection – CDMA or GSM: Only one gateway charging station with cellular modem is required per local group of charging stations. HTTPS and 128-bit AES encryption: Ensures secure network communications. Integrated RFID Reader: Recognizes and identifies Charge Point Network Smart Cards, and authorization smart cards from other charging systems. Future-proofed: Upgrade all firmware remotely via the network as new capabilities and functionality become available. Electric utility demand-side management: Communicates via an HTTPS secure link to utility and third party “Smart Grid” management systems to provide real-time load shedding of any group of charging stations. Vacuum fluorescent display: Bright and easy-to-read.

Contacts Global Resource Link LLC P.O. Box 1121 Newington, VA 22122 (703) 339-1700 (703) 339-1701 www.mygrlink.com For more information or for pricing please call 703-339-1700 Ext 100