(i) proper arrangement of reinforcing bars and

Slides:



Advertisements
Similar presentations
Plain & Reinforced Concrete-1 CE3601
Advertisements

1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Check Beam Shear.
2.2 STRUCTURAL ELEMENT BEAM
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Chp12- Footings.
Design of Concrete Structure I
REINFORCING DETAILING OF R.C.C MEMBERS
Reinforced Concrete Design-8
Lecture 9 - Flexure June 20, 2003 CVEN 444.
STAIRCASES. STAIRCASES Introduction Staircases provide means of movement from one floor to another in a structure. Staircases consist of a number of.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Chapter-7 Bond Development Length & Splices
Lecture Goals Slab design reinforcement.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Department of Civil Engineering NED University Engineering & Technology Building Prof Sarosh Lodi.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Slab Design.
Stresses Found In Structural Members. Forces Acting Simply Supported Beam 1.Bending.
Code Comparison between
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
Composite Beams and Columns
Beam Design.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Umm Al-Qura University Department of Civil & Structural Engineering 1 Design of reinforced concrete II Design of one-way solid slabs Lecture (1)
Plain & Reinforced Concrete-1 CE-313
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
WORKSHEET 4 BEAMS.
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
Umm Al-Qura University Department of Civil & Structural Engineering 1 Design of reinforced concrete II Design of Flat Slab Floors Lecture (3)
©Teaching Resource in Design of Steel Structures IIT Madras, SERC Madras, Anna Univ., INSDAG 1 COMPOSITE FLOORS - II.
Composite Construction
Reinforcement Information - Code
DESIGN OF SINGLY REINFORCED BEAM
Design of One Way Slabs CE A433 – RC Design T. Bart Quimby, P.E., Ph.D. Spring 2007.
Prof. Shrikant M. Harle Asst prof. Dept of Civil Engg PRMCEAM
Stairs :- Chaudhari Tanmay. M :-Gamit Vinay..
Dr Badorul Hisham Abu Bakar
AHSANULLAH UNIVERSITY OF SCIENCE & TECHNOLOGY DEPT
SLABS.
Theory of Reinforced Concrete and Lab. II
CIVL471 DESIGN OF RC STRUCTURES
Lecture 5 - Flexure June 11, 2003 CVEN 444.
786 Design of Two Way floor system for Flat Plate Slab
Code Comparison between
Introduction Used for covering spaces in the form of roof or floor
Outline: Introduction: a ) General description of project b) Materials
UNIT-IV SHEAR,TORSION AND BOND.
Lecture 39 - Design of Two-Way Floor Slab System
FOR 5TH SEMESTER DIPLOMA IN CIVIL ENGINEERING
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
SINGLY REINFORCED BEAM (R.C.C)
786 Design of Two Way Floor System for Slab with Beams
SINGLY REINFORCED BEAM (R.C.C)
Design of Reinforced Concrete
Reinforced Concrete Design-4 Design of T beams
Design Ribbed and Flat Slabs
BEAM BY WSM BY AQUIB ZAFAR Assist Professor ACET,Nagpur
Reinforced Concrete Design-4 Design of T beams
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
By :Dr. Aeid A. Abdulrazeg
Plain & Reinforced Concrete-1 CE3601
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Reinforced Concrete Design-3 Flexural Design of Beams
Reinforced Concrete Design-4 Design of T beams
Reinforced concrete column
Desig n Compute moment per meter
Presentation transcript:

(i) proper arrangement of reinforcing bars and Beams & Slabs Breadth of the beam b (i) proper arrangement of reinforcing bars and (ii) architectural considerations. b <= column width, or width of the wall Practical aspects b as 200, 230, 250 and 300 mm. b /D = 0.5 and 0.67.

Effective Depth d (ii) deflection of the beam. d is based on L/d ratio (i) the strength requirements of bending moment and shear force, (ii) deflection of the beam. d is based on L/d ratio For Simply Supported beams 1M span = 70mm or L/d = 15;may be assumed

Tension steel Ast Provide Longitudinal bars (i) Ast should provide the required moment of resistance = factored moment Mu (ii) should satisfy minimum and maximum pt requirements (iii) Ast (min) - As/bd = 0.85/fy (iv) Ast (max) - As = 0.04bD

Compression steel Asc Provide Longitudinal bars (i) Asc should provide the required moment of resistance = factored moment Mu (ii) should satisfy maximum pc requirements (iii) Asc (max) - As = 0.04bD

Concrete Grade, Steel Grade, ReBar Dia (i) Concrete: Minimum: M20 (ii) Steel: Fe250,Fe415,Fe500 (iii) Longitudinal Re Bars: #12, #16, #20,#25,#32 Dia Area (mm2) #8 50 #10 78.5 #12 113 #16 201 #20 314 #25 491 #32 804

General Design Considerations L/d ratio Since slabs are provided with less pt ( 0.3%), higher values are assumed, kt = 1.25 One way Simply supported Slabs = 20 x1.25 = 25 Cantilever = 7 x1.25 = 8 Continuous = 26 x 1.25 =32 Two Way ( Short span to be considered) Simply Supported = 35 Continuous (Restrained) = 40

3. Clear Cover=20 mm (Table 16A) 4. Rebar Dia: #8,#10,#12 2. Minimum Slab Thickness = 100mm. (practical) 3. Clear Cover=20 mm (Table 16A) 4. Rebar Dia: #8,#10,#12 5. Maximum Rebar Dia = (1/8) xD 6. Minimum Ast 0.12% of Total C/S area – HYSD 0.15% of Total C/S area – MS

7. Maximum Spacing Main Reinforcement: < Min(3d or 300 mm) Temperature and shrinkage reinforcement (Distribution) < Min(5d or 450 mm) placed perpendicular to main bars above main bars for sagging moments below main bars for Hogging moments

Bar Marks 8. Rebar Shapes Straight Bars at Bottom for Sagging Moments (CONTINUOUS EDGE) Straight Bars at Top for Hogging moments (Continuous Edge) Straight bars with Hooks (Discontinuous Edge) Bent-up bars used to resist both sagging and Hogging moments. (Not much preferred) U -bars used for corner reinforcement in two way restrained slabs

9. Bar marks Bar marks are short lines drawn at 450 at the ends of rebars They are used to distinguish rebar lines from other lines in drawing. Also the directions indicate the positioning of rebar's in slabs - whether to be placed at bottom or at top.