HIGH PERFORMANCE PRESSURE SYSTEMS.

Slides:



Advertisements
Similar presentations
ACTIVE LEARNING PROCESS
Advertisements

WHAT IS STEAM PRO? Thermoflow, Inc.
BeginningNext SlideBack End Program AVADAL 1 of 21 SK-1 Roller Apron Segment Overview.
MCS LWC MAGNUM ORIGINAL CONCEPTS  Designed to Control Loop Systems  Build to be generic and handle many configurations of Loop Controllers  Type of.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
ADX 150 – Engine Repair ADX 170 – Climate Controls
Refrigerators.
Unit 206: Domestic hot water systems
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
SAMPLE SLIDES OF THE 1-DAY SEMINAR FOR PUMP USERS
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Booster System Basics: Constant Speed Systems
Unit 206: Domestic hot water systems
© Emotron AB Protection against damage and downtime Emotron M20 Shaft Power Monitor.
Engineer Presentation
Vibration Sensors for Cooling Towers Challenges Cooling towers offer the vibration analyst many challenges in sensor selection, mounting and environmental.
Hydraulics.
Proper Pump Installation Practices
Our Plan – Weeks 6 and 7 Review energy relationships in single pipes Extend analysis to progressively more complex systems – Pipes in parallel or series.
Introduction to FLUID COPLING.
Marine Auxiliary Machinery
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Fuel Evaporation in Ports of SI Engines P M V Subbarao Professor Mechanical Engineering Department Measure of Useful Fuel …..
PENTAIR 1.
Hydronic Mechanical Controls
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Conservation of Mass, Flow Rates
Water piping design.
HVAC523 Circulator Pumps.
Week 1 Unit Conversions Conservation of Mass Ideal Gas Newtonian Fluids, Reynolds No. Pressure Loss in Pipe Flow Week 2 Pressure Loss Examples Flow Measurement.
Grundfos FLOW THINKING Air conditioning the Grundfos Way.
Hawke’s Bay Refrigeration
Settings & Adjustments. Settings & Adjustments.
Metso - Slurry Pumping.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
TECHNICAL TRAINING INVERTER-Y
SUBJECT CODE NAME OF SUBJECT TOPIC :::::: FLUID POWER ENGINEERING CENTRIFUGAL PUMP Parul Institute of Engineering & Technology.
So Far: Mass and Volume Flow Rates Reynolds No., Laminar/Turbulent Pressure Drop in Pipes Flow Measurement, Valves Total Head, Pump Power, NPSH This Week:
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
C5305 – WASTE WATER AND WATER SUPPLY ENGINEERING
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Prepared By Rohit G. Sorte M.Tech
Flow Characteristics of Port Fuel Injection System P M V Subbarao Professor Mechanical Engineering Department Matching of Injector with Engine Requirements.
Ullrich, DESY Dubna GDE XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser 1 Water cooling XFEL Desingn of the XFEL water cooling.
Copyright 2011, Toshiba Corporation. Toshiba International Corp - Houston Tx Jim Hartzel Section Mgr - Water / Waste Water Business 20 Yrs Field Service.
CENTIFUGAL PUMP OPERATION
VALVES IN PIPE LINES.
Fixed Orifice Tube Cycling Clutch System (FOTCC)
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
PV100&PV200 Solar Pumping VFD
With Electrical Grounding
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Speed control of three phase induction motor
Parul Institute of Technology
HIGH PERFORMANCE TEMPERATURE CONTROL.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Hot water Systems Heaters.
COMMON RAIL FUEL INJECTION SYSTEM
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
Loop Water Controller Overview
ENG421 (3c) – Pipes, Valves, Pumps
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
NEW ARISTON STORAGE BOILERS March, 2009.
Hydraulic Pump Power Power = rate of conversion of energy.
PUMPS AND DRIVERS NCCER
Presented by Mike Zacharias
Presentation transcript:

HIGH PERFORMANCE PRESSURE SYSTEMS

INDUSTRY PRESSURE CONTROL Wash & Clean Machine Tool Filtration - - - - Boiler Feed Mixing +++ Special Requirements

Challenges: Limited space Moist environment and high temperatures TEXT Pressure spikes Large changes in flow demand No flow is an operating condition! TEXT Pressure segments: 20 Bar 40 Bar 60 Bar 80 Bar Priority: Operator time ! - Water consumption Energy consumption Flow range: Increments of 40 liters/minute = 2,4m3/h corresponds to one cleaning station or one user.

Pumps built into cabinets, portable equipment and machine centers require small physical outline due to limited space. Compactness is often a critical and primary property.

OVER SYNCHRONOUS OPERATION Selected Pump: CRE3-9 Extended I/O Card – 3 fixed speeds, Analog Output 4kW MGE motor, Reduced Fan, 6000 rpm. Factory Configured OEM pump CR5-36 1253mm Pump End Length CR3-9 393mm CRE3-9 6000rpm/4kW

OVER SYNCHRONOUS OPERATION Advantages: Small size (physical space, handling, weight, packaging, small pump) Concerns: Ball bearing life OK Shaft seal life OK NPSH !! Vibration ! Limitations on pump !!! Acceleration cavitation: ! Influence ramp time NPSH Pressure Time/sec Standard speed Over Synchronous speed Delayed pressure built up

RUN AT POWER LIMIT Makes it possible to boost the pressure at lower flows by increasing the frequency. Gives the possibility to use the motor 100 % over the full flow range. Either get more pressure or choose an undersize motor

CONTROL SYSTEM Constant pressure Constant pressure Operating a pump in regulated mode based on a pressure sensor  obtain constant pressure in the system All cleaning stations will have the same pressure, and same flow independent of number of users Effective cleaning and controlled amount of water usage Pump operation depends on system design and application requirement Important is to avoid operating against closed valve, cavitation and over pressurizing the system Systems operating with feed pump or pressurized supply line can operate with a flow switch By opening a tap or satellite lance the flow through the switch will turn on the pump and it will operate until the load is turned off and the pump can ramp down to a stop Flow switch Instead of flow switch, the built-in stop function can be used The Pump will probe the system for low flow and automatically stop when no flow is present Constant pressure By operating the pump in regulated mode based on a pressure sensor, we obtain constant pressure in the system. That means that all cleaning stations will have the same pressure, and can deliver the same flow independent of how many users are active. That means effective cleaning and controlled amount of water usage. Systems operating with feed pump or pressurized supply line can operate with a flow switch. By opening a tap or satellite lance the flow through the switch will turn on the pump and it will operate until the load is turned off and the pump can ramp down to a stop. In stead of flow switch, the built in stop function can be used provided that non return valve tank and pressure sensor is attached. The Pump will probe the system for low flow and automatically stop when no flow is present.. Stop function

Sleeve deformation due to high pressure >100Bar STOP FUNCTION Sleeve deformation due to high pressure >100Bar Damaged ball bearings Thermal expansion of the water N CRNE3-9 sleeves

PROTECTION Avoid fault! Never place a non-return valve on the suction side of the pump unless a over pressure release valve is installed! Avoid fault! Different means of pump and system protection can be installed Temperature sensor in the top of the pump A PT100 sensor placed in the top of the pump is a cheap and effective way of protecting the system from damage and scolding due to dead heading. Setup combined with Limit exceed. SAVER and HM Large has dedicated inputs for PT100/1000 Discharge pressure measurement A limit exceed on high pressure on measured discharge pressure protects from pressure damage due to dead heading. A limit exceed on low pressure can protect from cavitation due to ”run out of curve” or dry run. Pre-pressure measurement or pre-pressure switch Protect against dry run and cavitation due to low feed pressure. Dry run protection Lictec placed in the top of the pump protects against dry run and high temperature due to dead heading. SAVER FM300 I/O card has direct input for the Lictec sensor unit. Under load Detects if the pump in below minimum power consumption indicating loss of prime or air in the pump. The function is at present not accessible in all MGEs. Pump motor and drive System is protected against overload, supply failures, high ambient temperature and more by the drive. Over pressure safety valve In case of a need for a non return valve on the suction side of the pump, a safety valve must be installed for prevention of pressure damage in the system and scolding. Power limit A trimmed power limit can cut of the pump curve and make it steeper by high flow in order to avoid cavitation. Constant pressure control High speed pumps with steep curves are often prevented from over pressurizing the pump at reduced flow by constant pressure operation, even though constant pressure is not needed from a system control point of view. Diaphragm tank A small tank placed directly on the piping and as a pipe extension (shooting direction of a pressure wave) can reduce water hammer.

SPECIAL SYSTEMS 80 Bar, 17 m3/h, BMS operated at 5500 rpm by IE4 motor Supplied by 70kW VFD with 690V supply The system is used for exterior cleaning on cruise ships The system is built and sold by Lagafors AB in Sweden, supported by the Industry Segment.

THANK YOU