GROUND FAULT & EARTH LEAKAGE MONITORS

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Electrical Systems Chapter 9.
The D.C. Scout Battery Distribution System Ground Locator
Isolation Verification Control Mining - Marine - Transit – Solutions LIVE Distributed By Locksafe Industrial Safety Equipment.
Chapter 12 Transformers. Chapter 12 Transformers.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Elec467 Power Machines & Transformers
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
Copier Jam Detector Design Problem
Sales Training Outline 2006 Klaus Tum Product Manager NEW Circuit Breakers 35 Royal Road Flemington, NJ
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
G GE Power Management MMII Intelligent MCC Controller.
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
Section 4: Electric Motors
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
Industrial Machine Control
 Four Components of a circuit  Power supply  Conductor  Load device  Controlling device  Power Supply  Generator  Line source (wall outlet)  Transformer.
1 INTRUSION ALARM TECHNOLOGY POWER SUPPLIES. 2 INTRUSION ALARM TECHNOLOGY Security systems shall have a primary power source and a secondary power source.
Codan 5700 Series C-Band Transceiver Technical Overview.
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
Inverter power supply symptoms can be typically broken down into the following categories: 1. All Outputs Normal: 2. All Outputs Dead (no output): 3.
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
Main contacts closed – RED Colour with ON
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
Fermilab AD E/E Support Department Fermilab’s Experience in Applying OSHA and NFPA 70E Requirements in Accelerator Power Supply Systems NFPA 70E Standard.
Protection of Power Systems
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
REDA Production Systems
Design of starters for AC motors C.K. PITHAWALA COLLAGE OF ENGINEERING & TECHNOLOGY Group no - 3 Name Enrolment no Chaudhari Darshan M Chaudhari.
BASIC ELECTRICITY AND MAGNETISM
Push Button Station and Relay
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
BUILDING LOAD NORMAL OPERATION 1. ATS are in normal position connected to utility source 2. All generator set paralleling circuit breaker open.
Automatic Transfer Switches
SPD II 1 for LV Power (AC/DC)
Protection of Power Systems
Power and Energy Energy (E) is the ability to do work
Making Circuits Safe SNC1P1 Findlay.
THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE Submitted by:
OVER VOLTAGE OR UNDER VOLTAGE
Grounding.
LOAD CUTOFF SWITCH UPON OVER VOLTAGE OR UNDER VOLTAGE
Circuit Protection Unit 9.
AUTOMATIC STREET LIGHT CONTROL USING LDR
TPS - Thyristor Power Supply for Resistive/Inductive Loads
Notes 5 ECE 3318 Applied Electricity and Magnetism Fall 2017
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
MPU-16A MOTOR PROTECTION UNIT.
MPU-16A / FPU-16 TEST UNIT TUTORIAL
FIGURE 22-1 Bulbs that have the same trade number have the same operating voltage and wattage. The NA means that the bulb uses a natural amber glass ampoule.
EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR
The D.C. Scout Battery Distribution System Ground Locator
THREE-PHASE GROUND-FAULT BASICS
NEUTRAL-GROUNDING-RESISTOR MONITOR
FIGURE 22-1 Bulbs that have the same trade number have the same operating voltage and wattage. The NA means that the bulb uses a natural amber glass ampoule.
HVI HIPOT TEST SET Pft sERIES.
Personal Protective Equipment
The Electric Circuit.
Copier Jam Detector Design Problem
What Is to Be Covered? Electrical Shock - Why Have GFCIs?
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
CECOM LAR Tropo Operation Course
6. USING THE TDR200 IN ANALOGUE MODE
Electrical components and systems
Lecture 2 Electrical and Electronics Circuits. After you study, and apply ideas in this Lecture, you will: Understand differences among resistance, capacitance,
Fluid Power System Electrical Control
Presentation transcript:

GROUND FAULT & EARTH LEAKAGE MONITORS SE-700 SERIES GROUND FAULT & EARTH LEAKAGE MONITORS This presentation presupposes audience familiarity with ground-fault basics. Startco Engineering is a leader in the field of ground-fault monitoring. Many of our protection relays, including Neutral Grounding Resistor Monitors, Motor Protection Units, and Ground-Fault Ground-Check Monitors, incorporate ground-fault monitoring. This presentation is about the SE-701, a purpose-built ground-fault monitor.

THE SE-700 FAMILY The SE-700 series are microprocessor-based earth-leakage monitors for impedance-grounded and solidly grounded systems. The SE-700’s detect earth-leakage current using a zero-sequence core-balance current transformer, and will trip on the selected level of zero-sequence current after the selected time delay.

THE SE-700 FAMILY: SE-701, SE-703, SE-704

SE-700 FAMILY FEATURES Fixed frequency or variable frequency Harmonic filtering (DFT) Fail-safe / non-fail-safe output operation Isolated trip contacts Signal input: Core-balance CT Open-CT detection Supply: 120 Vac, 240 Vac, 24 Vac, 120/240 Vac, 55 to 275 Vac and 75 to 275 Vdc, 9 to 36 Vdc, and 30 to 70 Vdc 0 - 5 Vdc analog output Mechanical-flag and LED trip indication Self-test feature Remote reset input Surface mount / DIN rail mount / optional panel mount To mount use two screws, snap onto a DIN rail, or panel mount with the optional PMA-55 kit (shown on upcoming slide). Fail Safe operation energises the relay contacts when the unit is not tripped. Hence the unit is in the tripped state when control power is lost. In non-fail-safe operation the relay contacts are energised only in the tripped state. Trip Inhibit, when activated, will not allow a trip when ground-fault current exceeds 11 times the CT-primary rating. This protects the circuit breaking device that the SE-701 is controlling by preventing it from clearing a fault much larger than it was designed to handle. This type of fault is a high level fault and should be cleared by overcurrent devices such as fuses or circuit breakers. The sensing device used to provide input to the SE-701 is a current transformer (CT). This can be a standard 1 Amp or 5 Amp secondary CT, or a sensitive nickel-core 5 Amp primary CT (EFCT-1 or EFCT-2). See CT selection chart. The SE-701 tolerates wide fluctuations in control power. The 120 V unit tolerates 72 to 138 Vac. The 240 V unit tolerates 144 to 276 Vac. Analog output indicates ground-fault current sensed by the CT. Output is 5 V when sensed current is 100% of the CT-primary rating. This output can be used to help trace the location of ground faults in a pulsing GF system.Normally-Open and Normally-Closed form Z contacts are provided. Form Z contacts are isolated. This allows, say, 120 Vac at one and 24 Vdc at the other. Their operation depends upon the choice of Failsafe or Non-Failsafe mode. The output relay rating is 8 A resistive, 250 Vac / 30 Vdc.

SE-701 FACE-PLATE FUNCTIONS INHB: LED indicates trip inhibit function active TRIP: LED trip indication PWR: Power on LED TRIP: Mechanical-flag trip indication % CT PRIMARY: Selectable ground-fault trip level as a % of CT primary rating TIME: Trip time can be set from 0.05 to 2.5 s The TEST button, when pressed for 1 second, causes the ground-fault circuit to trip, activates ground-fault indication, and operates the output relay. The one second delay is to prevent accidental, nuisance operation. Ground-Fault-Current Trip Level can be set from 1% to 99% of the CT-primary rating. For example if you have a 100:5 CT, the unit can be set to trip (or alarm) at settings between 1 A and 99 A in one amp increments. It should be set substantially below prospective ground-fault current. To avoid sympathetic tripping, the trip level must be above the system charging current. The Power On LED lights when supply power is applied Trip Inhibit lights when the output relay operation was inhibited during a high-current ground-fault (when enabled).. Reset when ground-fault trip is reset. Trip LED lights and trip flag flips to indicate a ground-fault trip. The LED flashes to indicate a CT-fault trip. The fluorescent flag remains flipped if supply power is removed. It is not reset by cycling the supply power. It is reset only by operating the reset circuit (front panel or remote). Trip time can be set at one of ten levels from 50 ms to 2.5 s. This switch is used to co-ordinate trip times of ground-fault devices in the system. This is to minimize the amount of equipment taken out of service in response to a ground-fault. A Trip remains latched until the RESET button is pressed (or the remote reset is pressed, or supply voltage is cycled). The reset circuit responds only to a single shot input, so a jammed RESET button or a shorted switch will not maintain a reset signal. TEST: Causes ground-fault circuit to trip RESET: Resets trip after fault is cleared

SE-701 SELECTABLE FEATURES AUTO RESET VARIABLE FREQ CT VERIFY ON INHIBIT ON NON-FAIL-SAFE LATCHING FIXED FREQENCY CT VERIFY OFF INHIBIT OFF FAIL-SAFE 5 4 3 2 1 Dead-front self-locking screw / clamp connectors 1-A CT Input 5-A CT Input EFCT Input Three dip switches are located beneath the hermetic cap located on top of the SE-701. The switches allow selection of: CT Verify On / Off Inhibit On / Off (Class II / I) Fail-Safe / Non-Fail-Safe Note the dead-front screw/clamp connectors (14 AWG).

SE-703: DESIGNED FOR AUSTRALIA’S MINING INDUSTRY Two-second power-loss hold-up time Sensitive protection without nuisance trips CT Verification and CT-loss trip SAA-AS2081 compliant

SE-703 FACE PLATE CT: CT Verification LED TRIP: LED trip indication PWR: Power on LED TRIP: Mechanical-flag trip indication LEVEL: Selectable ground-fault trip level—75 mA to 1000 mA TIME: Trip time can be set from 55 ms to 500 ms TEST: Causes ground-fault circuit to trip RESET: Resets trip after fault is cleared

SE-703 SELECTABLE FEATURES CT VERIFY ON VARIABLE FREQ NON-FAIL-SAFE CT VERIFY OFF FIXED FREQENCY FAIL-SAFE 3 2 1 EFCT Input Dead-front self-locking screw / clamp connectors

SE-704 FACEPLATE CT: CT Verification LED TRIP: LED trip indication PWR: Power on LED TRIP: Mechanical-flag trip indication LEVEL: Selectable ground-fault trip level—10 mA to 500 mA TIME: Trip time can be set from 30 ms to 1000 ms TEST: Causes ground-fault circuit to trip RESET: Resets trip after fault is cleared

SE-704 SELECTABLE FEATURES AUTO RESET CT VERIFY ON VARIABLE FREQ NON-FAIL-SAFE LATCHING CT VERIFY OFF FIXED FREQENCY FAIL-SAFE 4 3 2 1 SE-CS30 Input Dead-front self-locking screw / clamp connectors

PMA-55 PANEL MOUNT ADAPTER The PMA-55 panel mount adapter is used to bring the SE-701 to the front door of an enclosure. The PMA-55 is used in applications in which trip time and/or trip current set points must be operator accessible. The SE-701 is DIN rail mounted to the PMA-55 bracket. The bracket’s bezel conceals and protects the dead-front terminals, after installation. Ie: removing the bezel does not dismount the PMA-55.

SE-700 SECURITY FEATURE Remove the set-point selection knobs to make unauthorized adjustments more difficult

GROUND-FAULT CT SELECTION CHART EFCT & FLUX CONDITIONER 2.75” or 5.50” ID’s START IT>5A, or IP >100 A, or IS > 2.5 kA Note 1 YES NO ECONOMY PERFORMANCE IT < 0.5 A IS > 1 kA Note 2 IS < 5 kA IS < 8 kA MODEL 130 CT 5.75” ID Note 3 MODEL 120 CT 5.75” ID MODEL 170 CT 4.25” ID EFCT-1: 3.23” ID or EFCT-2: 6.10” ID IT : Ground-Fault Trip or Alarm Level IP : Prospective Ground-Fault Current IS : Surge Current (1.6 x LRA for motors) Note 1: IP > 800 A for MPU-16A. Note 2: Symmetrically locating phase conductors in the center of the CT window will reduce CT saturation and increase the surge-current limit. Note 3: If IT < 5 A, use a 500:5 or 100:1 CT and the EFCT input. If IP > 70 A, also use a SE-EFVC voltage clamp. Applies to: SE-701, MPU-16A, MPS & FPU-16 Use this selection flow chart to determine which ground-fault CT is appropriate for a given application. Basic information requrired is: ground-fault trip (or alarm) level, prospective ground-fault current, system surge current. Example: An SE-701 is monitoring a circuit with several motors with a total locked-rotor current of 1500 A. The supply transformer has a 25 A neutral grounding resistor (NGR). We want the SE-701 to trip on 100 mA ground-fault current. Beginning at START and moving right to the first decision block of the flowchart we see that ground-fault current trip level, IT, at 100 mA is less than 5A; prospective ground fault current, IP, at 25 A is less than 100 A; surge current, IS, at 1.6 x 1500 A = 2400 A is less than 2500 A. Therefore, we move down one level in the flowchart into another decision block. Again, IT, at 100mA is less than 500 mA so we move down one more level of the flowchart. Here we see that an EFCT earth fault current transformer with a flux conditioner is required. All that is left to decide is the CT window diameter. This is a function of phase cable size. The flux conditioner provides a low resistance path for magnetic flux. The result is elimination of local saturation of the CT—eliminating nuisance tripping due to this local saturation. The criterea for the decision between performance and economy CT’s are price and the possible future requirement for sensitive ground-fault current detection.

LOCATING PHASE CONDUCTORS IN A ZERO-SEQUENCE-CT WINDOW GAP A B C SPACER FLUX CONDITIONER An ideal window-type current transformer (CT) responds only to the sum of the currents flowing through its window; however, an actual CT may saturate if the phase currents are too large. This results in CT output even if the sum of the phase currents is zero. Saturation can be minimized by choosing a CT with an adequate core and symmetrically locating the phase conductors in the centre of the CT window. Use of a flux conditioner can eliminate local saturation. The right-hand figure includes a flux conditioner. If shields,drain,ground, or ground-check wires pass through the CT, return them through the CT before termination. Firmly secure the conductors in the centre of the CT window so they cannot be moved accidentally or under fault conditions. The gap between the conductors and the CT should be at least 12.7 mm (0.5 in). It is preferable to have a gap of 25.4 mm (1.0 in) or more. For multiple conductors per phase, arrange the conductors as shown in the figure. A spacer with the same diameter as the conductors should be used to separate phase conductors. Symmetrically locate the phase conductors in the CT window The gap between the conductors and the CT should be at least 12.7 mm (0.5 in) It is preferable to have a gap of 25.4 mm (1 in) or more

SE-701 TYPICAL APPLICATION v REMOTE RESET ANALOG OUTPUT +24Vdc 0 V GROUND-FAULT INDICATION TO PLC INPUT STOP START 1M O/L SAWMILL L N CURRENT TRANSFORMER This typical SE-701 circuit diagram shows: 5 A secondary CT input, a control transformer across load-side supply phases, a 110 Vac contactor controlled by momentary start switch in series with the fail-safe SE-701 output relay contacts, a 24 Vdc remote trip indicator light in parallel with a PLC input, a remote reset normally open switch, and a voltmeter connection to the analog output.