FEEDER PROTECTION UNIT

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
PYROCON12 De-Ice controller Technician Operation Presentation 2013.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
555 Timer ©Paul Godin Updated February Oscillators ◊We have looked at simple oscillator designs using an inverter, and had a brief look at crystal.
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
SYMAP-BC SYMAP-BC.
Introducing GAC’s New Line of Intelligent Generator Set Controllers
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
G GE Power Management MMII Intelligent MCC Controller.
Data Logger for Water Meter Function Continuously counts pulses from pulse output of the water meter (or other meters with pulse output) and periodically.
PYROCON12 De-Ice controller User Operation Presentation 2013.
G GE Power Management 369 Motor Management Relay.
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
1 Industrial Systems A dvanced L ine P rotection S ystem.
POWER PLANT USED IN TELECOM
Modular Inverter.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
Codan 5700 Series C-Band Transceiver Technical Overview.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
SmartMQn Motor Horner APG, LLC September 9, 2008.
Main contacts closed – RED Colour with ON
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
Power Supply. 2 Power Supply w/Line Conditioner The power supply is the heart of the Millenium System. It can support between 15 DCD boards (power for.
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
BUILDING LOAD NORMAL OPERATION 1. ATS are in normal position connected to utility source 2. All generator set paralleling circuit breaker open.
DIGITAL MULTIMETER DMG
This presentation is driven by the mouse or pointing device.
Lecture 10: Programmable Logic Controllers
User Operation Presentation
VARLOGIC NRC12 Varmetric Controller
THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE Submitted by:
MEDIUM VOLTAGE APPLICATIONS.
ABB i-bus® KNX Valve Drive Actuator VAA/A
CLOSED-LOOP MOTOR SPEED SENSOR & CONTROLLER
음향 시스템 사양서 POWER SUPLY WITH 3.5 PHOENIX CONNECTOR AMX: PSN6.5
555 Timer EEE DEPARTMENT KUMPAVAT HARPAL( )
SCADA for Remote Industrial Plant
TPS - Thyristor Power Supply for Resistive/Inductive Loads
HD SIGNAL CONDITIONER SERIES
INDUCTION MOTOR PROTECTION FOR SINGLE PHASING, OVERVOLTAGE AND OVER TEMPERATURE Submitted by:
EPR = Electronic Products and Relays
LDA Large Display for Analog Inputs
GROUND-FAULT GROUND-CHECK MONITOR
GROUND FAULT & EARTH LEAKAGE MONITORS
MPU-16A MOTOR PROTECTION UNIT.
IDM-3 3-PHASE AMMETER.
MOTOR PROTECTION SYSTEM
MPU-16A / FPU-16 TEST UNIT TUTORIAL
EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR
NEUTRAL-GROUNDING-RESISTOR MONITOR
HVI HIPOT TEST SET Pft sERIES.
De-Ice control devices
Protection Philosophy
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Module 1 – Power Supply AMC APS-PBC-60
Technician Operation Presentation
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
PAX2A Release.
PowerLogic™ offer for the basic metering market
PowerLogic PM5350 High-performance multifunction power meter
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
724 Temperature Calibrator
Presentation transcript:

FEEDER PROTECTION UNIT FPU-16 FEEDER PROTECTION UNIT

THE FPU-16 FEEDER PROTECTION UNIT The FPU-16 is a microprocessor-based feeder protection unit with programmable trip-and-alarm set points for phase protection, ground-fault protection, and current unbalance. Features of the FPU-16 include an operation counter, front-panel programming, independent trip-and-alarm relays, and an isolated analog output.

FPU-16 FEEDER PROTECTION UNIT Compact design-1/4 DIN size Temperature rating of -40°C to 60°C Panel or surface mount Supply voltage range of 85 to 135 Vac Program-change lockout

FPU-16 FEEDER PROTECTION UNIT Separate trip and alarm contacts - Fused - Form “C” - Fail-safe or non-fail- safe operation Plug-in terminal blocks

WHAT PROTECTION DOES AN FPU-16 OFFER? THERMAL OVERLOAD SHORT-TIME OVERCURRENT INSTANTANEOUS OVERCURRENT CURRENT UNBALANCE EARTH-FAULT RAMP MODE RESET ENTER SET POINT MOD STATUS MODES FPU-16 FEEDER PROTECTION UNIT

OPTIONAL ELECTROLUMINESCENT BACKLIT DISPLAY FPU-16 FACE PLATE LIQUID CRYSTAL DISPLAY MODE digit identifies mode VALUE digits Display set points, trip and alarm codes, and meter readings TRIP/ALARM, Red LED On: Trip or alarm Flashing: Program-change lockout defeated PROCESSOR, Green LED Indicator On: Processor functional OPTIONAL ELECTROLUMINESCENT BACKLIT DISPLAY MODE LIST MEMBRANE SWITCH KEYPAD RAMP switch Adjusts value digits ENTER switch Enters values, accesses alarm set points and values at trip MODE switch Selects modes “0” through “F” RESET switch Resets trips and alarms

FPU-16 BACK PLATE - + 13 14 15 16 A B C O M 17 18 19 20 P E 21 22 23 24 F - + CNTR ICT SHIELD 12 11 10 9 8 7 6 5 4 3 2 1 L1 L2 F2 8A F1 ANALOG 1 2 3 4 5 6 7 8 NC I 26 25 RS 485 TRIP ALARM L1 and L2 - are for control power. Units can be ordered with optional 120 Vac or 240 Vac and 50 or 60 Hz. There is also an optional DC power supply. 5-6-7 - are the form “C” trip relay. It is 10 A rated and fused at 8 A. Relays can be configured to operate in the fail-safe or non-fail-safe mode. 8 - System ground 9 - Key Pin. High voltage lower block cannot be plugged into low voltage upper terminals. 10-11-12 - Form “C” alarm relay. 23 -24 - isolated analog output or RS-485. 21-22 - Input for Earth-fault CT. 20-21 - Program enable. These pins must be connected to allow program changes. 17-18-19 - Input for RTD or Thermistor. 13-14-15-16 - ICT-2 Interface CT input. ICT-2 shown on the next slide.

ICT-2 INTERFACE CT Provides mounting flexibility Mounting ICT-2 close to CT’s provides: - Less signal loss -Eliminates open CT hazard

FPU-16 TYPICAL APPLICATION EARTH-FAULT CT PHASE CT'S SUPPLY LOAD 12 11 10 9 8 1 5 S R 7 6 4 3 2 ICT-2 13 14 15 16 A B C O M E F 18 19 17 Y X 20 21 22 23 24 25 26 27 MPU PHASE C CT PHASE A CT PHASE B CT EARTH FAULT ANALOG OR RS-485 OUTPUT 13 14 15 16 17 18 19 20 21 22 23 24 A B C C N C P E - + M O C E CNTR ANALOG/RS-485 OUTPUT F ICT SHIELD FPU-16 ALARM TRIP F2 N F1 L2 L1 C 12 11 10 9 8 7 6 5 4 3 2 1 N L TO TRIP COIL OR LOCKOUT RELAY ALARM A

I2t THERMAL PROTECTION CURVE 10000 8000 PERCENT I2t 6000 DYNAMIC LIMIT 5000 100 4000 3000 PERCENT I2 t 2000 50 1000 800 600 500 0.5 1.0 400 MULTIPLES OF RATED CURRENT 300 200 CLASS 20 SECONDS 100 80 60 50 40 30 CLASS RANGE 1 s TO 45 s AT 600% 0% I2t 20 25% I2t 50% I2t 10 8 6 5 4 75% I2t 3 2 1 1 2 3 4 5 6 7 8 9 10 11 12 MULTIPLES OF RATED CURRENT

SHORT-TIME OVERCURRENT SETTINGS MAXIMUM 9x PHASE CT PRIMARY RATING FEEDER CURRENT TRIP SET POINT TRIP TIME = 3, 6, 12, OR 24 CYCLES ALARM SET POINT ALARM TIME = 3, 6, 12, OR 24 CYCLES 1x PHASE CT PRIMARY RATING MINIMUM

INSTANTANEOUS OVERCURRENT SET-POINT RANGE MAXIMUM 9x PHASE CT PRIMARY RATING TRIP SET POINT TRIP TIME =0.25 TO 3 CYCLES FEEDER CURRENT ALARM SET POINT ALARM TIME = 0.25 TO 3 CYCLES 1x PHASE CT PRIMARY RATING MINIMUM

CURRENT UNBALANCE SET-POINT RANGE 75% MAXIMUM PERCENT CURRENT UNBALANCE TRIP SET POINT TRIP TIME =5 SECONDS ALARM SET POINT ALARM TIME = 1 SECOND 5% MINIMUM

EARTH-FAULT CURRENT SET-POINT RANGE 100% of CT-primary rating MAXIMUM EARTH-FAULT CURRENT TRIP SET POINT TRIP TIME=3, 6, 12, OR 24 CYCLES ALARM SET POINT ALARM TIME = 12 CYCLES 1% of CT-primary rating MINIMUM

FPU-16 SETUP MODES MODE 6: EARTH-FAULT-CT-PRIMARY RATING (Ie) Range: 5 A to 2000 A MODE 7: PHASE-CT-PRIMARY RATING (Ip) Range: 20 A to 1200 A MODE 8: RATED CURRENT (In) Range: 9 A to 800 A

MODE 5-PROGRAMMABLE OPTIONS SHORT-CIRCUIT TRIP TIME: 3, 6, 12, or 24 cycles EARTH-FAULT TRIP TIME: 3, 6, 12, or 24 cycles I2t IMMEDIATE RESET: on / off ALARM LATCH: on / off AUTORESET (MODE 0): on / off RELAY OPERATING MODE: TRIP RELAY: fail safe / non fail safe ALARM RELAY: fail safe / non fail safe ANALOG OUTPUT PARAMETER: current, I2t, earth leakage

METERING MODES MODES A, b, AND C: AMMETERS <ENTER> displays pre-trip value MODE d: PERCENT I2t, TIME-TO-RESET, EMERGENCY THERMAL RESET MODE 9: PERCENT UNBALANCE <ENTER> displays pre-trip value MODE E: EARTH LEAKAGE <ENTER> displays pre-trip value MODE F: OPERATION COUNTER

OPTIONS AVAILABLE FOR THE FPU-16 MOUNTING: Panel or surface POWER SUPPLY: AC: 120 Vac, 240 Vac, or 120/240 Vac switch selectable DC: 12 Vdc, 24 Vdc, or 48 Vdc FREQUENCY: 50 or 60 Hz SIGNAL OUTPUT CONFIGURATION: ANALOG: 4-20 mA, 0-5 Vdc, 0-10 Vdc COMMUNICATIONS: RS-485 A-B or Modicon protocols (data logging available) DUAL OUTPUT: Analog and RS-485 available ELECTROLUMINESCENT BACKLIT DISPLAY REMOTE-KEYPAD INPUT

RS-232 TO RS-485 CONVERTER (485CSP2) FPU-16 COMMUNICATIONS 23 24 RAMP MODE RESET ENTER FEEDER PROTECTION UNIT SET POINT MODES STATUS MODES STARTCO FPU-16 SE-485 T(A) T(B) R(A) R(B) SE-TA485 FR. GND TD(B) TD(A) RD(A) RD(B) +12VDC GND WHT BLK RTS SD ON OFF CONTROL ECHO TD ENABLE RD RS-232 TO RS-485 CONVERTER (485CSP2) RS-485 RS-232 DC POWER SUPPLY SHIELD 23 24 FEEDER PROTECTION UNIT 1 TO 63 FPU-16’s or MPU-16A’s SET POINT MODES STATUS MODES RAMP MODE RESET ENTER STARTCO FPU-16 23 24 FEEDER PROTECTION UNIT SE-485 SET POINT MODES STATUS MODES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 RAMP MODE RESET ENTER STARTCO FPU-16 23 24 FEEDER PROTECTION UNIT SE-TA485 SET POINT MODES STATUS MODES RS 232 RAMP MODE RESET ENTER STARTCO FPU-16