OTR based measurements for ELI-NP Gamma Beam Source

Slides:



Advertisements
Similar presentations
Erdem Oz* USC E-164X,E167 Collaboration Plasma Dark Current in Self-Ionized Plasma Wake Field Accelerators
Advertisements

J. Rudolph, Helmholtz-Zentrum Berlin EuCARD 2nd ANNUAL MEETING Slice emittance measurements at the ELBE superconducting RF photoinjector.
Low energy electron beam as a nondestructive diagnostic tool for high power beams. P. Logachev, D. Malutin, A. Starostenko, BINP, RUPAC’2006, Novosibirsk.
Bunch shape monitor for Linac-4 A.V.Feschenko Institute For Nuclear Research (INR), Moscow , Russia.
Compton based Polarized Positrons Source for ILC V. Yakimenko, I. Pogorelsky BNL Collaboration meeting, Beijing, January 29-February1, 2006.
Two-dimensional and wide dynamic range profile monitor using OTR/fluorescence screens for diagnosing beam halo of intense proton beam Y. Hashimoto, T.
Compton Linac for Polarized Positrons V. Yakimenko, I. Pogorelsky, M. Polyanskiy, M. Fedurin BNL CERN, October 15, 2009.
Gamma Beam Systems a simple introduction. Purpose of the machine Deliver a high performance photon beam: Variable energy Highly polarized High intensity.
EuroNNAc Workshop, CERN, May 2011 External Injection at INFN-LNF ( integrating RF photo-injectors with LWFA ) Luca Serafini - INFN/Milano High Brightness.
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
Linac e+ source for ILC, CLIC, SuperB, … Vitaly Yakimenko, Igor Pogorelsky November 17, 2008 BNL.
Transverse emittance Two different techniques were used to measure the transverse emittance. The multislit mask in the injector 9 MeV Quadrupole scan for.
Compton/Linac based Polarized Positrons Source V. Yakimenko BNL IWLC2010, Geneva, October 18-22, 2010.
Compton based Polarized Positrons Source for ILC V. Yakimenko Brookhaven National Laboratory September 12, 2006 RuPAC 2006, Novosibirsk.
Transverse Profiling of an Intense FEL X-Ray Beam Using a Probe Electron Beam Patrick Krejcik SLAC National Accelerator Laboratory.
Transverse beam size measurement High energy micron electron beam non-invasive diagnostics based on diffraction radiation G.Naumenko*, A.Potylitsyn, L.Sukhikh.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
SFLASH  SASE interference setup & optics rough estimation 1d estimation 3d estimation summary.
SPATIAL RESOLUTION OF NON- INVASIVE BEAM PROFILE MONITORBASED ON OPTICAL DIFFRACTION RADIATION A.P. Potylitsyn Tomsk Polytechnic University, , pr.
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
G. Ferioli, R. Jung - LHC-BI Review Workshop November 19&20 LHC Screen Profile Monitors G. Ferioli, R. Jung Introduction BTV LHC layout Monitor set-up.
Y. Roblin, D. Douglas, F. Hannon, A. Hofler, G. Krafft, C. Tennant EXPERIMENTAL STUDIES OF OPTICS SCHEMES AT CEBAF FOR SUPPRESSION OF COHERENT SYNCHROTRON.
NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,
W.S. Graves 2002 Berlin CSR workshop 1 Microbunching and CSR experiments at BNL’s Source Development Lab William S. Graves ICFA CSR Workshop Berlin, Jan.,
P. A. POSOCCO CERN – BE/ABP Intra-Beam stripping at SPL: should we be worried? 5 th SPL Collaboration meeting.
ALICE setup: update on the installation 18/10/2010 Angela Intermite.
Accelerator Laboratory of Tsinghua University Generation, measurement and applications of high brightness electron beam Dao Xiang Apr-17, /37.
2 February 8th - 10th, 2016 TWIICE 2 Workshop Instability studies in the CLIC Damping Rings including radiation damping A.Passarelli, H.Bartosik, O.Boine-Fankenheim,
G.R.White: F.O.N. T. From Ground Motion studies by A.Seryi et al. (SLAC) ‘Fast’ motion (> few Hz) dominated by cultural noise Concern for structures.
1 RTML Emittance Measurement Station Yuri Kubyshin (1), Robert Apsimon (2), Hector García (1,2) (1) Technical University of Catalonia (UPC) (2) CERN CLIC.
Beam Profile Monitor for Spot-Scanning System Yoshimasa YUASA.
AFAD 2014 Synchrotron Status of Compact X-ray Source at LUCX Kazuyuki Sakaue Waseda University Laser Undulator Compact X-ray source.
Ultra-short electron bunches by Velocity Bunching as required for Plasma Wave Acceleration Alberto Bacci (Sparc Group, infn Milano) EAAC2013, 3-7 June,
Experience with Novosibirsk FEL Getmanov Yaroslav Budker INP, Russia Dec. 2012, Berlin, Germany Unwanted Beam Workshop.
What did we learn from TTF1 FEL? P. Castro (DESY).
X-band Based FEL proposal
Polarization of final electrons/positrons during multiple Compton
EUROTeV Diagnostics WP5
S.M. Polozov & Ko., NRNU MEPhI
Emittance measurements for LI2FE electron beams
Diagnostic & Control Status
Summary of SPARC first-phase operations
Electron Beam Diagnostics at REGAE
Beam based measurements
Slice Parameter Measurements at the SwissFEL Injector Test Facility
A compact, soft X-ray FEL at KVI
Have a chance to operate your own beam at CERN
Stefano Romeo on behalf of SPARC_LAB collaboration
Tunable Electron Bunch Train Generation at Tsinghua University
The SPARC_LAB Thomson source
17/10/2016 Reserch Activity Report 6D Phase Space Electron Beam Analysis And Optimization For Rf Linac Based Inverse Compton Scattering Radiation Sources.
Few Slides from RF Deflector Developments and Applications at SLAC
Application of a Streak camera at PITZ
Review of Application to SASE-FELs
Free Electron Lasers (FEL’s)
F. Villa Laboratori Nazionali di Frascati - LNF On behalf of Sparc_lab
Profile measurements at CTF
Beam size diagnostics using diffraction radiation
LCLS Injector Diagnostics
Compact linear accelerator FLUTE: status update
Val Kostroun and Bruce Dunham
Breakout Sessions SC1/SC2 – Accelerator Physics
Linac Diagnostics Commissioning Experience
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
Proposal for Smith-Purcell radiation experiment at SPARC_LAB
Injector Diagnostics Status
DANE Compton ring for ultra high flux photons in the 100 KeV-10 MeV energy range D. Alesini (LNF, INFN Frascati)
Generation of Magnetized Bunched Electron Beam for MEIC Cooler
Experience with photoinjector at ATF
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

OTR based measurements for ELI-NP Gamma Beam Source Title OTR based measurements for ELI-NP Gamma Beam Source Supervisor: L. Palumbo Co-Supervisor: A. Mostacci M. Marongiu Accelerator Physics Doctoral Course

Outline OTR properties GBS main parameters OTR Screens Thermal issues Fatigue Stress Photons Evaluation Beam Imaging Magnification Resolution Energy Measurements Angular Distribution Data Analysis

OTR Properties Optical Transition Radiation (OTR) screens are widely used for profile measurements The radiation is emitted when a charged particle beam crosses the boundary between two media with different optical properties The visible part of the radiation is used and an observation geometry in backward direction is mainly chosen Advantages Instantaneous emission process  Single shot measurements Good linearity Disadvantages The process of radiation generation is invasive The radiation intensity is lower in comparison to scintillation screens

Electron Beam Parameters @ IP Electron Beam Specifications Max. Energy at IP [MeV] 280 – 720 Macro Pulse rep. Rate [Hz] 100 Number of bunches up to 32 Bunch spacing [ns] 16.1 Bunch length [ps] 0.91 Bunch charge [pC] 25-250 εn_x,y [mm·mrad] 0.2-0.6 Bunch Energy Spread < 0.1%

Linac diagnostics Non-intercepting diagnostics: Charge measurements: 4 Integrating Current Transformers (bunch by bunch) Position measurements: 29 stripline BPMs (Macro pulse) 4 cavity BPMs (bunch by bunch) Beam Loss Monitor System Intercepting diagnostics: Phase-Space measurements: 23 Beam Screens (YAG and OTR)

Beam envelope along the Linac From Gun to S-Band (80MeV) C-Band (280MeV) A. Bacci, A. Giribono, C. Vaccarezza

Thermal Analysis OTR 32 bunches, 250pC each M. Marongiu, et al., https://doi.org/10.1016/j.nima.2016.07.040

Fatigue Stress 6 seconds Equivalent Von Mises Stress (Pa) F. Cioeta, et al., ISBN 978-3-95450-182-3, pag. 246-249

Photons Evaluation (400-700 nm) continuous lines (515-585 nm) dashed lines M. Marongiu, et al., Proceedings of IBIC 2017

Gated intensified camera 82%@550nm @ SPARC 46% for Basler scA640-70gm Hamamatsu Datasheet

Camera lens layout Camera Lens 180mm w/o teleconverter (2x) 180mm lens with teleconverter (2x) 180mm lens with teleconverter (1.4x) 180mm lens The resolution is 1/x (mm). The sizes of each horizontal line are 2,5/x for the length and 1/(2x) for the width (mm) and vice versa for the vertical lines. F. Cioeta, D. Cortis

Camera lens test-bench Camera Lens 180mm w/o teleconverter (2x) Camera Lens 105mm w/o teleconverter (2x) 180mm lens with teleconverter (2x) 180mm lens with teleconverter (1.4x) 180mm lens The resolution is 1/x (mm). The sizes of each horizontal line are 2,5/x for the length and 1/(2x) for the width (mm) and vice versa for the vertical lines. M. Marongiu et al., ISBN 978-3-95450-182-3, pag. 238-241

Camera lens Results Camera Lens 180mm w/o teleconverter (2x) 1:8 Screen (3 cm) 1:2 Beam (1 mm) 105mm 105mm with teleconverter (2x) 180mm 180mm with teleconverter (1.4x) 180mm with teleconverter (2x) M. Marongiu et al., ISBN 978-3-95450-182-3, pag. 238-241

Gaussian Reconstruction 5 Samples Error ~7% If Resolution=30µm and σ>19µm If σ=10µm and Resolution<16µm 20 Samples Error <<0,01% If Resolution=30µm and σ>75µm If σ=10µm and Resolution<4µm 8 Samples Error ~4% If Resolution=30µm and σ>30µm If σ=10µm and Resolution<10µm M. Marongiu et al., ISBN 978-3-95450-182-3, pag. 238-241

Energy Measurements SPF ~ 120 MeV ~ 120 pC @ SPARC Measurements @ SPARC_LAB

Data Analysis Data Set 1 Data Set 2 Carica 100pC e 120pC e enrgy spread 0.1% nei 2 casi Data Set 2 European Advanced Accelerator Concepts Workshop 2017

Layout @ SPARC_LAB  60 cm  20 cm @SPARC_LAB

Conclusions and Further Development A Gamma ray Compton source for nuclear physics research in the context of ELI initiative is being built. High repetition rate (100Hz), multi bunch operation (32 bunches) A high resolution diagnostics is required in order to verify the beam parameters (especially at the interaction point): OTR Near Field regime PSF dominated beam diagnostics Bunch to bunch measurements  Gated camera Distributed energy measurement  Possible layouts (i.e. Zemax) Single Shot measurements  Plasma accelerated beams (i.e. EuPRAXIA@SPARC_LAB)

Thank you for your attention!

Intensifier Characterization Study of the non linearity of the intensifier Good SNR Avoid Saturation Find Optimal Gain Value for given values of photons per pixel (different working point) Courtesy of A. Variola