National Electrical Code Article 310

Slides:



Advertisements
Similar presentations
Christel Hunter, Alcan Cable Butch Hartwick, FCI Burndy
Advertisements

Bonding and Grounding What? Why? How?
National Electrical Code 2008
Grounding Electrodes.
Unit 11 Wire Tables and Conductor Sizes. Objectives: Discuss factors that determine conductor ampacity. Discuss resistance of wire. Determine insulation.
Basic Electricity.
FIRE PUMP ELECTRICAL CONFIGURATIONS UNDER 600 VOLTS.
REVIEW OF CODE BREAKFAST QUESTIONS Brought to you by fellow members who attended the Section Meeting.
Master Examination Practice Drill # Ted “Smitty” Smith.
DAY 4 CHAPTER 3 CONDUCTOR SIZES,TYPES, ETC.. Continuous Load. A load where the maximum current is expected to continue for 3 hours or more. Continuous.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
EET Electronics Survey Chapter 9 - Circuit Conductors & Wire Sizes.
FIBER OPTIC CABLE CONSTRUCTION
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
Electrical Principles and Wiring Materials
2014 CHANGES TWO MINUTE DRILL COPYRIGHT TED “SMITTY” SMITH ©2014.
 E4 Electrical Installation #2 Wire Sizing and Materials.
©Ted “Smitty” Smith This speed drill focuses on calculations that will be required for the journeyman and masters examination. The question slide.
Electrical Principles and Wiring Materials
AWG, American Wire Gauge
Electrical Principles and Wiring Materials
Copyright 2005 Ted "Smitty" Smith Two Minute Drill Number Three Improving your skill in code Look Up Increasing Speed Drill.
Electrical Principles and Wiring Materials. OBJECTIVES 1. AM16.01 Define common electrical terms. 2. AM16.02 Compute electrical energy use and cost. 3.
©Ted “Smitty” Smith  This speed drill is designed to help you practice calculations. The slides will transition in three and one half minutes instead.
Electrical Principles and Wiring Materials. Principles of Electricity n Electricity is a form of energy that can produce light, heat, magnetism, chemical.
{ Electricity. { Who invented electricity? No one Benjamin Franklin is credited with the discovery.
Two Minute Drill Number 26- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Electrical Principles and Wiring Materials Unit #31.
Two Minute Drill Number 27- Residential Improving your skill in code Look Up Increasing Speed Drill Copyright 2008 Ted "Smitty" Smith.
Calculation Speed Drill # NEC
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
Electrical Principles and Wiring Materials Unit #31.
Electrical Wire Identification
Objective Describe materials used in electric wiring.
Speed Drill 51 Wireways and Raceways.
Electrical Principles and Wiring Materials Original Power Point Created by Casey Osksa Modified by Georgia Agricultural Education Curriculum Office June.
Daily Lesson Electrical Conductors Prepared by: Brian Alexander This lesson is from Virginia Tech and has not been edited by the Georgia Curriculum Office.
Ag. Mechanics for Beginning Teachers
2014 NEC Code Changes Class Part IV
2014 NEC C ODE C HANGES C LASS P ART III C ALCULATIONS Ted “Smitty” Smith 8/15/2014 E Light Electric Services, Inc.
2014 NEC C ODE C HANGES C LASS P ART II Ted “Smitty” Smith 8/15/2014 E Light Electric Services, Inc.
Ag Eng I Electricity Unit E. Electricity Q. Who invented electricity? A. No one, it is based on laws of physics Benjamin Franklin is created with the.
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
Installation of Heating, Cooling, and Refrigeration Systems Electricity for Refrigeration, Heating and Air Conditioning 7th Edition Chapter 8 Installation.
WIRES, CONDUITS AND RACEWAYS Class Instructor : VINCENT J. DAYAG JR,MSArch.UAP.PIEP. Architect / Environmental Planner.
Smitty’s Two Minute Drill Grounding
Electrical Principles and Wiring Materials
Electrical Conductors
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
HOW TO SIZE ELECTRICAL CIRCUITS
Electrical Principles and Wiring Materials
Advanced Calculations Drill 1 for the 2011 NEC
License Examination Practice Drill
E4 Electrical Installation
2011 Changes Two Minute Drill
Electrical Wire Identification
E4 Electrical Installation
Types of Cables.
Electrical Principles and Wiring Materials
Electrical Principles and Wiring Materials
Conductors and Cables 2017 NEC
Calculation Speed Drill #1
Two Minute Drill: Raceways and Boxes 2017
Electrical Wire Identification
EET 323 – Electrical System Design Lecture 6: Conductors and Over-Current Protection Radian Belu, PhD.
Electrical Principles and Wiring Materials
Smitty’s Two Minute Drill Varied Number 7
Calculations Review Drill
Presentation transcript:

National Electrical Code Article 310 3/31/2017 1:24 PM National Electrical Code Article 310 © 2007 Microsoft Corporation. All rights reserved. Microsoft, Windows, Windows Vista and other product names are or may be registered trademarks and/or trademarks in the U.S. and/or other countries. The information herein is for informational purposes only and represents the current view of Microsoft Corporation as of the date of this presentation. Because Microsoft must respond to changing market conditions, it should not be interpreted to be a commitment on the part of Microsoft, and Microsoft cannot guarantee the accuracy of any information provided after the date of this presentation. MICROSOFT MAKES NO WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, AS TO THE INFORMATION IN THIS PRESENTATION.

Conductors for General Wiring (A) Insulated - Conductors Shall be Insulated Exception: Where covered or bare conductors are specifically permitted else where in this code. (B) Conductor Material. – Conductors in this article shall be of aluminum, copper – clad aluminum, or copper unless otherwise specified. 310.3 Stranded Conductors Where installed in raceways, conductors of size 8 AWG and larger shall be stranded. Exception: As permitted or required elsewhere in this Code.

Conductors for General Wiring 310.8 Locations (A) Dry Locations. – Insulated conductors and cables used in dry locations shall be any of the types identified in this Code. (B) Dry and Damp Locations. – Insulated conductors and cables used in dry and damp locations shall be Types FEP, FEPB, MTW, PFA, RHH, RHW, RHW-2, SA, THHN, THW, THW-2, THHW, THWN, THWN-2, TW, XHH, XHHW, XHHW – 2, Z, OR ZW.

Conductors for General Wiring 310.8 Locations (cont.’d) (C) Wet Locations. – Insulated conductors and cables used in wet locations shall comply with one of the following: Be moisture – impervious metal – sheathed Be types MTW, RHW, RHW-2, TW, THW, THW-2, THHW, THWN, THWN-2, XHHW, XHHW-2, ZW. Be of a type listed for use in wet locations.

Conductors for General Wiring 310.8 Locations (cont.’d) (D) Locations Exposed to Direct Sunlight. – Insulated conductors or cable used where exposed to direct rays of the sun shall comply with: Conductors and cables shall be listed, or listed and marked, as being sunlight resistant. Covered with insulating material, such as tape or sleeving, that is listed, or listed and marked, as being sunlight resistant This material was extracted from Mike Holt Training Materials copyright 2007 by permission. Visit mikeholt.com or call 1.888.NEC.CODE (632-2633) for more information.

Conductors for General Wiring 310.9 Corrosive Conditions. - Conductors exposed to oils, greases, vapors, gases, fumes, liquids, or other substances having a deleterious effect on the conductor or insulation shall be of a type suitable for the application.

Conductors for General Wiring 310.10 Temperature Limitation of Conductors. No conductor shall be used in such a manner that its operating temperature exceeds that designated for the type of insulated conductor involved. In no case shall conductors be associated together in such a way, with respect to type of circuit, the wiring method employed, or the number of conductors, that the limiting temperature of any conductor is exceeded.

Conductors for General Wiring 310.10 Temperature Limitation of Conductors This material was extracted from Mike Holt Training Materials copyright 2007 by permission. Visit mikeholt.com or call 1.888.NEC.CODE (632-2633) for more information.

Conductors for General Wiring 310.11 Marking. (A) Required Information. All conductors and cables shall be marked to indicate the following information, using the applicable method described in 310.11(B): (1) The maximum rated voltage. (2) The proper type letter or letters for the type of wire or cable as specified elsewhere in this Code. (3) The manufacturer's' name, trademark, or other distinctive marking by which the organization responsible for the product can be readily identified. (4) The A W G size or circular mil area. (5) Cable assemblies where the neutral conductor is smaller than the ungrounded conductors shall be so marked.

Conductors for General Wiring 310.13 Conductor Constructions and Applications. Insulated conductors shall comply with the applicable provisions of Table 310.13, 310.62, 310.63, and 310.64

Conductors for General Wiring Table 310.13 Provides useful information about wire styles and uses.

Conductors for General Wiring Voltage drop can occur when wire sizing is not considered. E = I X R Voltage = Amp times Resistance #10 wire = 1.00 ohms @ 1,000 feet 15 v = 15 Amp x 1.00 ohm 115v – 15v = 100v

Conductors for General Wiring Adjustment for temperature exposure and wiring limit within a conduit. This material was extracted from Mike Holt Training Materials copyright 2007 by permission. Visit mikeholt.com or call 1.888.NEC.CODE (632-2633) for more information.

Conductors for General Wiring 310.15 Ampacities for Conductors Rated 0 – 2000 volts (1) Tables or Engineering Supervision. Ampacities for conductors shall be permitted to be determined by tables or under engineering supervision, as provided in 310.15(b) and (c). (2) Selection of Ampacity. Where more than one calculated or tabulated ampacity could apply for a given circuit length, the lowest value shall be used.

Conductors for General Wiring 310.15 Ampacities for Conductors (cont.’d) (B) Tables. Ampacities for conductors rated 0 – 2000 volts shall be as specified in the Allowable Ampacity Table 310.16 through 310.19 and Ampacity Table 310.20 through 310.23 as modified by (1) through (6). (2) Adjustment Factors. (a) More Than Three Current – Carrying Conductors in a Raceway or Cable. Where the number of current – carrying conductors in a raceway or cable exceeds three, or where single conductors or multcondutor cables are stacked or bundled longer than 600 mm (24 in.) without maintaining spacing and are not installed in raceways, the allowable ampacity of each conductor shall be reduced as shown in Table 310.15(b)(2)(a).

Conductors for General Wiring Table 310.16

Conductors for General Wiring Use Table 310.15(b)(2)(a) to adjust current carrying capacity more than 3 conductors share the same raceway or conduit.

Conductors for General Wiring When the exposure temperature exceeds 86º F then a correction factor is applied.

Conductors for General Wiring 310.15 Ampacities for Conductors (cont.’d) (3) Bare or Covered Conductors. Where bare or covered conductors are used with insulated conductors, their allowable ampacities shall be limited to those permitted for the adjacent insulated conducts. (4) Neutral Conductor (a) A neutral conductor that carries only the unbalanced current from other conductors of the same circuit shall not be required to be counted when applying the provisions of 310.15(b)(2)(a).

Conductors for General Wiring 310.15 Ampacities for Conductors (cont.’d) (5) Grounding or Bonding Conductor. A grounding or bonding conductor shall not be counted when applying the provisions of 310.15(b)(2)(a)