ECE 476 POWER SYSTEM ANALYSIS

Slides:



Advertisements
Similar presentations
Announcements Be reading Chapters 9 and 10 HW 8 is due now.
Advertisements

Announcements Be reading Chapters 8 and 9
RT3b – André Smit, Siemens USA
Announcements Be reading Chapter 6, also Chapter 2.4 (Network Equations). HW 5 is 2.38, 6.9, 6.18, 6.30, 6.34, 6.38; do by October 6 but does not need.
Power System Analysis/ Power System 1 EEE 4113/ EEE 3131
ECE 333 Renewable Energy Systems Lecture 13: Per Unit, Power Flow Prof. Tom Overbye Dept. of Electrical and Computer Engineering University of Illinois.
Chapter 7 SYSTEM PROTECTION
EE369 POWER SYSTEM ANALYSIS
OVER CURRENT RELAY The relay has two settings. These are the time setting and the plug setting. The time setting decides the operating time of the relay.
Lecture 18 Fault Analysis Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Protection of Microgrids Using Differential Relays
Lecture 22 Unbalanced Faults and Power System Protection Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Queensland University of Technology CRICOS No J Protection of distributed generation connected networks with coordination of overcurrent relays.
Announcements Read Chapters 8 and 9
Announcements Read Chapters 8 and 9 HW 9 quiz today
Lecture 22 Unbalanced Faults and Power System Protection Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
ECE 476 Power System Analysis Lecture 22: System Protection, Transient Stability Prof. Tom Overbye Dept. of Electrical and Computer Engineering University.
Announcements Read Chapters 10 and 11
Announcements Read Chapters 11 and 12 (sections 12.1 to 12.3)
ECE 476 Power System Analysis Lecture 18: LMP Markets, Symmetrical Faults and Components Prof. Tom Overbye Dept. of Electrical and Computer Engineering.
Lecture 24 Transient Stability Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Lecture 19 Fault Analysis, Grounding, Symmetrical Components Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM.
ECE 498HZ: Power Distribution System Analysis
Protection of Power Systems
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
Power System Protective Relaying-Part One
Protection of Power Systems
Lecture 22 Power System Protection, Transient Stability Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems Prof. Hao Zhu Dept. of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
Design a protection System of 220/33kV Grid Station United Arab Emirates University College of Engineering Saif Mohammed AL Aryani Ahmed Soruor.
Announcements Please read Chapters 11 and 12
Announcements Design Project has firm due date of Dec 4
Announcements Please read Chapters 8 and 9
Effects of GIC Neutral Blocking Devices (NBDs) on Transmission Lines Protection Performance and Potential for Resonance.
Announcements Please read Chapters 9, 10 and 11 HW 8 quiz today
Announcements Design Project has firm due date of Dec 4.
Protection of Power Systems
Announcements Please read Chapter 3
Announcements Please read Chapters 9, 10 and 11
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 Power System Analysis
ECE 476 Power System Analysis
Protection of Power Systems
ECEN 460 Power System Operation and Control
ECEN 460 Power System Operation and Control
ECE 476 POWER SYSTEM ANALYSIS
THREE-PHASE GROUND-FAULT BASICS
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
ECE 333 Green Electric Energy
Chapter 7 System Protection
A Tutorial on the Application and Setting of Collector Feeder Overcurrent Relays at Wind Electric Power Plants By: Stephanie Mercer.
Peter van Oirsouw (Phase to Phase)
EET 323 – Electrical System Design Lecture 9: Grounding
Interconnection of AES With The Grid
Power System Protective Relaying-Part One
ECE 476 POWER SYSTEM ANALYSIS
Review of Distribution Network Protection
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECEN 615 Methods of Electric Power Systems Analysis
ECE 476 POWER SYSTEM ANALYSIS
Power system operation and control
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
ECE 476 POWER SYSTEM ANALYSIS
Presentation transcript:

ECE 476 POWER SYSTEM ANALYSIS Lecture 22 Power System Protection, Transient Stability Muhammad Abdul Retha lefte Al-Badri Department of Electrical and Computer Engineering

Announcements Be reading Chapters 9 and 10 After exam read Chapter 11 HW 9 is 8.4, 8.12, 9.1,9.2 (bus 2), 9.14; do by Nov 10 but does not need to be turned in. Start working on Design Project. Firm due date has been extended to Dec 1 in class Second exam is on Nov 15 in class. Same format as first exam, except you can bring two note sheets (e.g., the one from the first exam and another) Exam/solution from 2008 will be posted on website shortly Exam covers through Chapter 10

In the News: Boulder municipalization Last week Boulder, CO narrowly voted to move forward with municipalization of their electric grid Currently Boulder is in the Xcel Energy electric service territory (Xcel is a large Investor Owned Utility) Xcel has recently decided not to continue funding the Boulder “SmartGridCity” initiative, which has cost $45 million, triple its original cost. Xcel does not wish to sell its electric grid in Boulder, saying it would be extremely expensive for Boulder to go on their own. Source: NY Times 11/3/11; Thanks to Margaret for pointing out this story

Power System Protection Main idea is to remove faults as quickly as possible while leaving as much of the system intact as possible Fault sequence of events Fault occurs somewhere on the system, changing the system currents and voltages Current transformers (CTs) and potential transformers (PTs) sensors detect the change in currents/voltages Relays use sensor input to determine whether a fault has occurred If fault occurs relays open circuit breakers to isolate fault

Power System Protection Protection systems must be designed with both primary protection and backup protection in case primary protection devices fail In designing power system protection systems there are two main types of systems that need to be considered: Radial: there is a single source of power, so power always flows in a single direction; this is the easiest from a protection point of view Network: power can flow in either direction: protection is much more involved

Radial Power System Protection Radial systems are primarily used in the lower voltage distribution systems. Protection actions usually result in loss of customer load, but the outages are usually quite local. The figure shows potential protection schemes for a radial system. The bottom scheme is preferred since it results in less lost load

Radial Power System Protection In radial power systems the amount of fault current is limited by the fault distance from the power source: faults further done the feeder have less fault current since the current is limited by feeder impedance Radial power system protection systems usually use inverse-time overcurrent relays. Coordination of relay current settings is needed to open the correct breakers

Inverse Time Overcurrent Relays Inverse time overcurrent relays respond instan-taneously to a current above their maximum setting They respond slower to currents below this value but above the pickup current value

Inverse Time Relays, cont'd The inverse time characteristic provides backup protection since relays further upstream (closer to power source) should eventually trip if relays closer to the fault fail Challenge is to make sure the minimum pickup current is set low enough to pick up all likely faults, but high enough not to trip on load current When outaged feeders are returned to service there can be a large in-rush current as all the motors try to simultaneously start; this in-rush current may re-trip the feeder