Using Biological Activity Reaction Tests (BART) to Monitor Microbially-Influenced Corrosion in Cast Iron Pipes Darlyce Simpson1, Steve Craik1 and Rasha.

Slides:



Advertisements
Similar presentations
Biocorrosion Monitoring System - BIOX - Witold Michalowski Dirk Steinmann.
Advertisements

Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
VII. Water Treatment C. Supplementation (fluoridation) of drinking water treatment, D. Special processes of drinking water treatment D. Special processes.
Wellington S. Tichenor, M.D. Associate Clinical Professor of Medicine, New York Medical College Sinusitis from Nontuberculous Mycobacteria in Tap Water.
Determining Uses of Water. Next Generation Science / Common Core Standards Addressed! HS ‐ ETS1 ‐ 2. Design a solution to a complex real ‐ world problem.
Acid Mine Drainage: From Formation to Remediation CE Aquatic Chemistry Julie Giardina Dominike Merle.
Lead Contamination in Water Supply For Caudill Laboratories and Chapman Hall Meeting with Occupants and Students April 23, 2007.
Water quality issues – ‘natural’ controls Acidity – low pH due to infiltration of acidified precipitation; acids from mine drainage; pyrite oxidation.
An Introduction to Acid Mine Drainage by George Mitchell and Tim Craddock.
Introduction to Chlorine Dioxide Technology. Chlorine Dioxide is … Oxidizer and Disinfecting Biocide Molecular Formula – ClO 2 2/3 the oxidation potential.
Removing Iron from Drinking Water. Iron in drinking water Guidelines Iron is essential for humans Where does the iron that we need come from?? – Usually.
Lecture 4: Free chlorine and hypochlorite Prepared by Husam Al-Najar The Islamic University of Gaza- Environmental Engineering Department Environmental.
Water Quality & Intermittent Water Supplies Dr. Nawal Sunna’ Water Authority, Ministry of Water & Irrigation Amman, Jordan Consultation on Minimum Household.
Designing an Internal Corrosion Program NACE Eastern Area Conference Roy D. Fultineer Jr.
WATER QUALITY CRITERIA & STANDARDS
-Lead in Architecture- Nehaa Haneef Loyola University Chicago Science and Society Introduction: Lead in Architecture A broad definition of architecture.
PRESENTER: IP MOLOBELA
Potable water pipe-wall biofilm bacterial community response to conditioning shear stress and a hydraulic disturbance in a full-scale pipe loop facility.
Abstract/Background Worldwide, corrosion of drinking water pipes and build-up of scales on the interior pipe wall impacts both the quality and quantity.
New York City Department of Environmental Protection Bureau of Water Supply Water Quality Bio-Stability of New York City’s Distribution Water Authors:
Properties of Matter Section 15.2.
Shipwrecks, Corrosion and Conservation
Corrosion Control Iron’s nasty side…rust All metals corrode There are various types of corrosion – Physical corrosion, or “erosion corrosion” – Stray.
Identifying Water Sources and Quality Standards. Next Generation Science / Common Core Standards Addressed! WHST.9 ‐ 12.7 Conduct short as well as more.
Water Quality Testing SVN3E.
Describing Redoximorphic Features Prepared by: Mr. Brian Oram Wilkes University
The Drinking Water Treatment Process
Acid Mine Drainage. Yellow boy in a stream receiving acid drainage from surface coal mining. An Enviromental problem in coal- Mining region Degrades water.
MRWS GROUND WATER RULE (GWR) PREPARED BY JOHN CAMDEN MRWS GROUND WATER TECH
Washington’s Water Use Efficiency Rule May Require Increased Coordination for Many Utilities Dan Sander, P.E. Senior Engineer.
TARNISH & CORROSION By Head of Department Dr. Rashid Hassan Assistant Professor Science of Dental Materials Department DENTAL SECTION (W.M.D.C) ABBOTTABAD.
TIP Activity Waste Water Treatment Group 3. Teaching TIPS All students should be encouraged to develop understanding of natural resources and conserving.
Lynsay Bensman 06 October 2009 Errors in Sampling/Monitoring in an Internal Corrosion Program NACE Eastern Area Conference.
Properties of Alcohols pre-lab lecture
After successful completion of this Lesson, you have learned to: List the 3 indicators of soil health. List the physical indicators that help to know a.
Ideapreneurship-universal entertainment paradise.
Conducting Water Quality Tests. Next Generation Science / Common Core Standards Addressed! HS ‐ ESS2 ‐ 5. Plan and conduct an investigation of the properties.
The Water Cycle. What are some things that you think are in your water?
ENVIRONMENTAL SCIENCE 5.3 Before You Drink the Water.
What Makes Hard Water Hard?
An Overview DCC Annual Retreat February 20, 2012.
Prediction of Soil Corrosivity Index: A Bayesian Belief Network Approach Gizachew A. Demissie, PhD student Solomon Tesfamariam,
Harry D. Gong, Jr., P.E. Engineering Coordinator Drinking Water Revolving Loan Fund Bureau of Public Water Supply Mississippi State Department of Health.
Grade 7 Science Unit 2 After a physical change, the substance is still the same substance Changes in state are physical changes The substance may have.
Messaging & Testimonials
Revised Total Coliform Rule Rural Water Workshops
Water supply Physical Characteristics of Water Ghada Kassab, PhD
What has happened here and why?
Total Coliform Rule (TCR)
Aim to look at a ‘varity of reactions…’
CHAP. 2.2 – WATER TO DRINK.
Word … and chemical equations
Signs of a Chemical Reaction
Operation Water Biology
Microbial Community Analysis of a Floating Island System in a Stormwater Wet Detention Basin Danielle Winter, Dessy Owiti, François Birgand, Terrence Gardner,
Bujar H. Durmishi1*, Arianit A. Reka, Murtezan Ismaili, Agim Shabani
Word … and chemical equations
Private Homeowner Drinking Water Issues
Factors influencing the rate of corrosion
IDENTIFYING CORROSION MECHANISMS BASED ON CORROSION COUPON ANALYSIS
OHWARN Workshop Disruption of Service Rule Update
Energy Conservation Through the Removal of Bio-film
Environmental Engineering
Treatment – pH Correction / Conditioning
Physical Properties of Matter
Understanding the Environmental Requirements for Fish
Pesticides The use of pesticides for agricultural and non-agricultural purposes is widespread and there are approximately 450 different active ingredients.
See for Yourself! What’s in Your Water?
WATER QUALITY CRITERIA & STANDARDS 1. Acceptability aspects 2.Microbiological aspects 3.Chemical aspects 4. Radiological aspects.
Acceptability aspects: Taste, odour and appearance  Water should be free of tastes and odours that would be objectionable to the majority of consumers.
Presentation transcript:

Using Biological Activity Reaction Tests (BART) to Monitor Microbially-Influenced Corrosion in Cast Iron Pipes Darlyce Simpson1, Steve Craik1 and Rasha Maal-Bared2 1Analytical Operations, Quality Assurance and Environment, EPCOR Water Services, Edmonton, Alberta, Canada. 2Scientific Services, Quality Assurance and Environment, EPCOR Water Services, Edmonton, Alberta, Canada. Introduction Results and Discussion Results and Discussion (continued) In 2015, EPCOR Water Services received complaints of water discoloration and the formation of an orange film on surfaces that come in contact with tap water from residents of an Edmonton neighborhood. It was determined that the likely cause was the corrosion of aging cast iron pipes used in that section of the water distribution system. Microbially- influenced corrosion (MIC) is corrosion caused by the presence and metabolic activity of microorganisms on a metal surface. Iron-related bacteria (IRB), sulfate-reducing bacteria (SRB) and biofilm forming bacteria are considered to be the main types of bacteria associated with MIC in cast iron pipes (1). IRB oxidize dissolved ferrous iron to form ferric oxide resulting in an insoluble reddish precipitate. Hydrogen sulfide gas produced by the break down of sulfur compounds by SRB also contributes to corrosion. Biofilm forming bacteria facilitate the creation of biofilms, which provide an environment for IRB and SRB to grow. Biological activity reaction tests (BART) can be used for the semi-quantitative evaluation of nuisance bacteria such as IRB and SRB. Chemical Analyses SRB and biofilm bacteria were detected in swab samples taken from a water meter in an adjacent affected house and from the removed section of the water main prior to replacement (Table 1). The toilet tank swab showed the presence of biofilm bacteria but no SRB. It is likely that the water meter and the cast iron pipe provided a more suitable environment to culture populations of SRB. Indications of the presence of IRB were seen in all of the samples but were more difficult to determine with certainty as the observed reaction time exceeded the standard length of the test. This may be due to very low populations or a low level of bacterial activity from environmental stressors (2). During the connection to the temporary water supply, IRB, SRB and biofilm bacteria were not detected suggesting that the premise plumbing may not have been colonized by significant populations possibly due to the lack of suitable materials that support these bacteria. After the water main replacement, SRB were not detected in either water or swab samples. Biofilm bacteria were detected in water samples indicating that these bacteria are still present in the water main upstream of the repair area. The observed IRB levels were similar to those seen in the initial samples collected prior to replacement. Figure 1. Changes in iron concentrations prior to, during and post water main replacement from one of the homes in the affected area. As expected, samples collected prior to the water main replacement showed elevated iron concentrations with a marked decrease in concentrations after residents were connected to the temporary water supply (Figure 1). A slight increase in iron concentrations was observed again after the replacement, which gradually decreased with water usage over time. Manganese and aluminum concentrations did not fluctuate. Objectives Providing high quality and reliable drinking water to the public is a priority for EPCOR Water Services. This study aimed to: Evaluate if BART can be used to determine if IRB and SRB influence water quality changes; Identify the long-term changes in IRB and SRB after a section of the cast-iron water main suspected to have undergone MIC was replaced. Bacteriological Analyses Conclusions and Limitations   Test Sample Date Sample Point IRB SRB Biofilm Prior to Replacement October 8, 2015 Water Meter Swab + +++ ++ Toilet Tank Swab - October 20, 2015 Water Main Swab (West) Water Main Swab (East) Connected to Temporary October 28, 2016 Tap Water Sample Post Replacement November 5, 2015 December 14, 2015 February 5, 2016 March 29, 2016 - Absent + Not Aggressive ++ Moderately Aggressive +++ Aggressive It is important to develop a method for identifying and forecasting MIC in order to better manage and prioritize cast iron water main replacements. More studies may be needed to determine the effectiveness of this method on biofilm samples as it is difficult to obtain a representative sample and therefore difficult to standardize and quantify these results. Results from these tests are semi-quantitative thus any numbers produced by BART need to be evaluated and explained to customers with caution. IRB and SRB have no known effects on human health but they can impact the aesthetic quality of water delivered to customers. Materials and Methods Water grab samples and biofilm swabs were collected from three homes in the affected area for chemical and/or bacteriological analyses: a) prior to water main replacement; b) during the main replacement while the homes were connected to a temporary water supply; and c) for five months after the replacement was completed. Chemical analyses included, but were not limited to: turbidity, chlorine, color, and metals (iron, manganese and aluminum). BART were used for IRB, SRB and biofilm bacteria. Table 1. Summary of BART results prior to, during and post water main replacement from one of the homes in the affected area. References Beimeng, Q., Chongwei, C., Yixing, Y. 2015. Int. J. Electrochem. Sci. 10: 545 - 558. Droycon Bioconcepts Inc. 2004, Biological Activity Reaction Test BART User Manual. Retrieved from http://www.dbi.ca/BARTs/PDFs/Manual.pdf. Contact  For more information, please contact Darlyce Simpson at dsimpson@epcor.com. Figure 2. BART Biodetectors