FP420 Detector Cooling Thermal Considerations

Slides:



Advertisements
Similar presentations
Conduction Conceptests
Advertisements

Modeling and Sizing a Thermoelectric Cooler Within a Thermal Analyzer Jane Baumann C&R Technologies, Inc. Littleton, Colorado.
Engine Cooling And Lubrication
Electronics Cooling MPE 635
Cloud Chamber Cooling Analysis
HEAT PUMPS.
Basic Refrigeration Cycle
Manchester 09/sept/2008A.Falou & P.Cornebise {LAL-Orsay}1 CALICE Meeting/ Manchester Sept 2008 SLAB Integration & Thermal Measurements.
Using Copper Water Loop Heat Pipes to Efficiently Cool CPUs and GPUs Stephen Fried President Passive Thermal Technology, Inc.
The Use of Small Coolers for Hydrogen and Helium Liquefaction
Extended Surface Heat Transfer
TopDrive: RP3 Thermal Management of Battery Module Unit of Electronics Integration and Reliability Department of Electronics.
Solar Orbiter EUS: Thermal Design Considerations Bryan Shaughnessy, Rutherford Appleton Laboratory 1 Solar Orbiter EUV Spectrometer Thermal Design Considerations.
Solar Orbiter EUV Spectrometer
Conductors and Insulators
Heating and cooling BADI Year 3 John Errington MSc.
23 October 2005MICE Meeting at RAL1 MICE Tracker Magnets, 4 K Coolers, and Magnet Coupling during a Quench Michael A. Green Lawrence Berkeley Laboratory.
Mechanical Status of ECAL Marc Anduze – 30/10/06.
1 Update on Focus Coil Design and Configuration M. A. Green, G. Barr, W. Lau, R. S. Senanayake, and S. Q. Yang University of Oxford Department of Physics.
Part-C Main topics B1- Electronics cooling methods in industry Heat sinks and cold plates for electronic cooling "Heat sinks" Heat pipes in electronic.
CHE/ME 109 Heat Transfer in Electronics
Cryostat Structural, Thermal, and Vacuum Systems 14 October 2008 Martin Nordby, Gary Guiffre, John Ku, John Hodgson.
Heat Sink Selection Thermal Management of Electronics
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
© 2011 Autodesk Freely licensed for use by educational institutions. Reuse and changes require a note indicating that content has been modified from the.
Heat Transfer: Physical Origins and Rate Equations
PAX DETECTOR THERMAL SIMULATION 1Vittore Carassiti - INFN FEFz-Juelich, 27/10/2008.
Lecture 12 Current & Resistance (2)
Summary of thermal conduction gas tests for ANITA Goal: To measure the heat transport of different gases in a force-convection condition.
RF-Accelerating Structure: Cooling Circuit Modeling Riku Raatikainen
H. Dinwiddie NRAO-EVLA1 X-Band OMT Evaluation SOC Design Thermal Analysis 2009/10/01.
Status of vacuum & interconnections of the CLIC main linac modules C. Garion TE/VSC TBMWG, 9 th November 2009.
ROSIER Ph End cap – TPC - LC DRAFT Definition of the front-end electronics and its cooling in the Alice TPC experiment Page 1A The Alice TPC.
26 April 2013 Immanuel Gfall (HEPHY Vienna) Belle II SVD Overview.
Calorimeter Analysis Tasks, July 2014 Revision B January 22, 2015.
Thermal measurements in Glasgow Richard Bates, Isaac Bonad, Craig Buttar.
What are common results of heat transfer? Case #1, no phase transition or work done. How much does the temperature vary? Heat is energy in transit! Positive,
PXL Cable Options LG 1HFT Hardware Meeting 02/11/2010.
BTeV Pixel Substrate C. M. Lei November Design Spec. Exposed to >10 Mrad Radiation Exposed to Operational Temp about –15C Under Ultra-high Vacuum,
LHCb VELO Meeting LHCb VELO Cooling System Bart Verlaat (NIKHEF) 25 February 2003.
Summary of thermal conduction gas tests for ANITA Goal: To measure the heat transport of different gases in a force-convection environment. John Clem,
Update on Micro Channel Cooling Collaboration Meeting , G. Nüßle.
Active Solar heating Used for space and or water heating
Unit 2: Heat Chapter 6: “Heat is transferred from one place to another by three different processes.”
How much makes it through the atmosphere. Why a seasonal variation? First, why do we have seasons? Earth’s axis is tilted 23.5° to the plane of its orbit.
Present status of production target and Room design Takashi Hashimoto, IBS/RISP 2015, February.
CERN – FP420 - Thermal/cooling - Berend Winter Peltier Cooling Thermal Considerations Berend Winter.
FP420 Hybrid Mechanical Design Ray Thompson / Manchester Manchester Xmas O7 Ray Thompson Julian Freestone, Andy Elvin.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Manoj kumar 2009JE0406 Mining machinery engineering.
High Granularity Calorimeter Workshop Ideas for cooling of a high granularity calorimeter Nick Lumb, IPN-Lyon 02/02/2015.
Lesson 7: Thermal and Mechanical Element Math Models in Control Systems ET 438a Automatic Control Systems Technology 1lesson7et438a.pptx.
Michael A. Green and Heng Pan
Thermoelectric Modules (TEM)
The PV Cell Cell, Module & Array.
INTRODUCTION : Convection: Heat transfer between a solid surface and a moving fluid is governed by the Newton’s cooling law: q = hA(Ts-Tɷ), where Ts is.
Development of a Thermoelectric Cooling Prototype
Micro-channel Cooling
VELO Thermal Control System
Performance of an Automated Water Based Cooling System for CBM MuCh
Barrel TRT Module Cooling
ECE Engineering Design Thermal Considerations
Effect of Using 2 TE units on Same Heat Sink
High-temperature Properties of Schottky Diodes Made of Silicon Carbide
LHCb VErtex LOcator For precision measurements of CP-violation at CERN (GENEVE) HALF of DETECTOR Si strip detector Read-out electronics Secondary vacuum.
Thermal aspects Unité mixte de recherche CNRS-IN2P3
ET 438a Automatic Control Systems Technology
LHCb VErtex LOcator ENGINEERING DEPARTMENT
LHCb VErtex LOcator For precision measurements of CP-violation at CERN (GENEVE) HALF of DETECTOR Si strip detector Read-out electronics Secondary vacuum.
THERMODYNAMIC IN ELECTRONICS
Presentation transcript:

FP420 Detector Cooling Thermal Considerations Berend Winter

The Detector Array Flexible Link (electronics signals) Prox. Electronics Tracker Cell Detector Plane (CE7) Beam Line Thermal Interface to Cold Sink The detector array is moved together with the beam line tube (not shown here) which has flexible links (preserving primary vaccum) with the main beam line. This means that the interface between the detector array cold sink and the vacuum enclosure (secondary vacuum) moves together (no relative displacement). Thermal Design Goal: tracker cell operating at -20°C

Dissipated Heat The detector consists of 5 super modules Each super module consists of 2 detector planes (Al/Si) with each holding 2 detectors on each side (4 in total per super module) Each super module has an ASIC underneath each detector and the 4 silicon detectors within each super module share one proximity electronics module Each detector/ASIC combination dissipates 0.5 W or less Each proximity electronics module dissipates 1.0 W This makes for a total of 3 W per super module and 15 W in total for each detector array head (5 super modules) As we will see later on 5 W needs to be added due to parasitic heatloads

Heat Paths Each super module has two thermal interfaces to a cold sink (5 on each side) Each detector (10 in total for a detector array) is connected to (relatively) warm front end electronics via a flexible link The detector array is mounted on an interface (vacuum enclosure) at room temperature (20 to 30 deg-C) The detector array is radiation coupled with the vacuum enclosure The thermal hardware (straps) are radiation coupled with the vacuum enclosure The cold sink has to interface through the vacuum enclosure and is somehow conductively coupled with it

Thermal Network Around the Detectors (one detector plane) Conducted Heat Radiated Heat Cold Sink Interface Si tracker cell 0.5 W Flex link Al/Si detector plane (support structure) Prox. Electronics (0.5 W) Si tracker cell 0.5 W Flex link cables Cold Sink Interface support Vacuum Enclosure

Parasitic Heat Loads The detector array as a whole is supported by the vacuum enclosure, heat will flow from the warm vacuum enclosure to the cold detector array. Using Torlon support rods the parasitic heat load can be limited to less than 1.5 mW/Celcius (6 rods, 5x5x50 mm) with the detector array running at -30°C and the vacuum vessel at +30°C this gives less than 0.1 W parasitic heat load for the detector array. The proximity electronics are connected through the vacuum vessel wall, 30 conductors (28 AWG) 30 wires, 28 gauge with a minimum length of 100 mm and a thermal jump of -30°C to +30°C gives 0.5 W per proximity electronics PCB (one for each super module). This is 2.5 W for the whole detector array.

Parasitic Heat Loads (Continued) Radiated Heat Detector Array absorbs 2.2 W total (worst case) Thermal straps absorb 0.05 W total (worst case)

Tracker Cell Model In 2006 an ESATAN analysis was performed to assess the thermal gradient over the tracker cell. With updated materials and dimensions the results are still the same. Gradient between tracker cell and the CE7 carrier plate is 2.5°C (worst case)

Thermal analysis of Al/Si CE7 structure A thermal analysis was performed on the CE7 support structure. Applied heatloads: 1 W for two tracker cells 0.5 W for prox. elec. 0.5 W for parasitics Applying a boundary condition of -29.3°C the interface with the tracker cell is -22.5°C As a result the tracker cell itself is sitting at -20°C. -29.3°C -22.5°C

Thermal Gradients Since we know the heat loads we can calculate the thermal gradient at each stage of the design. Analysis has shown a gradient of 2.5°C from the active part of the tracker cell to the support structure (CE7 plane) with a heatload of 0.5 being dissipated in the tracker cell. This is worst case (but not extreme) since most of the heat will be dissipated in the ASIC underneath. The heat dissipated in the proximity electronics and the parasitics (radiation and conduction) were analysed and resulted in a gradient of 6.8°C between the CE7 area where the tracker cell is mounted and the cold interface. The total heat flow per CE7 plane is 2 W (dissipated and parasitic) The gradient between the tracker cell and the cold interface is 9.3°C in total. For the rest of the design we need a cold interface to the CE7 planes at -30°C and we need to conduct 2 W per interface. (Two sinks on each side of a super plane makes ten in total, conducting 20 W in total)

Peltier Cooling Peltier Cooling forces a thermal gradient over a series of solid state elements capable of pumping heat Not a very efficient way of cooling. About 2% efficient for the first stage of detector cooling in our case (with updated heat loads) Maximum gradients in order of 70°C (without pumping capacity)

Peltier Cooling no longer Viable Last year the assumptions on the total amount of heat dissipated and the total amount of parasitics were seriously underestimated (factor of 3). Simple hand calculations now show that the Peltier cooling option is no longer viable. The efficiency has dropped by a factor of ~4. So we need to dump significantly more heat with less efficient Peltier elements (around 2% efficiency). We need to dump an awful lot of heat to the outside of the vacuum vessel and use fins with forced convection as a heat sink to go all electric (peltier and cooling fans) on the cooling. For example computer CPU fans only get rid of a Watt or two in optimal conditions. That is by using a significant thermal gradient (about 70°C) Using Peltier devices we estimate the total heat we need to dump (somehow) into the tunnel to be significant more than 1 kW…

Fluid Cooling Using a simple fluid cooling loop with a cold plate on the inside of the vacuum vessel we should be able to dump the heat efficiently. This is by means of a copper tube soldered to the back of a copper plate. The copper plate (gold plated) has holes where thermal straps from the detector can be bolted on firmly. This is a technique routinely used in cryogenics/vacuum chambers. The interface through the wall is via a standard (off the shelf) thin wall stainless tube feed through.

Heat Transfer The heat flows per CE7 plane into a copper shim and then into a copper block where the heat of two CE7 planes combines before it flows into the cold plate. -29.3°C CE7 1 W Cu block 2 W Fluid Cooled Copper Plate -29.3°C CE7 1 W

Heat Transfer Continued The thermal jump between the CE7 planes and the cooling plate is 25.7°C making the total jump between tracker cell and cooling plate 35°C. Conclusion: The cooling plate has to be at least -55°C and be able to pump 10 W (one cooling plate on each side of the detector arrays)

Cooling Thermostats Cooling thermostats come in wide range. Lauda is a prime supplier of cooling thermostats capable of cooling down to -90°C, most likely not radiation hard Can CERN provide for a cooling fluid line?