Eltutar, Kadir; Akcetin, Tulay A.; Ozcelik, N. Demet Istanbul Education and Research Hospital Department of Ophthalmology The authors state that they have.
Progressive Multifocal Intraocular Lens G. Rubiolini M.D. Italy Disclosure of finanacial interest Author's research is partially funded.
INTRA-OCULAR LENS POWER CALCULATION IN POST- REFRACTIVE SURGERY ASIAN EYES USING THE HAIGIS-L FORMULA Dr Daphne Han, FRCS Dr Wei-Han Chua, FRCS Dr Peter.
IOL power calculation after refractive surgery A. Peyman, MD.
Personalised eye modelling for customised intraocular lens designs Matthew Sheehan, Eamonn O’Donoghue, Conor Sheil and Alexander Goncharov Photonics Ireland,
M. Allison Roensch, MD, Preston H. Blomquist, MD, Nalini K Aggarwal, MD, James P. McCulley, MD Department of Ophthalmology University of Texas Southwestern.
Placement of Toric Intraocular Lens and the Long-term Change in the Axis of Corneal Astigmatism after Sutureless Cataract Extraction by Phacoemulsification.
Bilateral phacoemulsification and intraocular lens (IOL) implantation for bilateral corneal ectasia after photorefractive keratectomy (PRK) Department.
Correction of Astigmatism with Toric IOL After Previous RK
JAIRO E. HOYOS, MD MELANIA CIGALES, MD Instituto Oftalmológico Hoyos Barcelona - SPAIN.
G. Jacob 1,2, C. Bouchard 2, S. Kancherla 1. Edward Hines, Jr. VA Hospital, Hines, IL, Department of Ophthalmology 1. Loyola University Medical Center,
Hong Kong Eye Hospital Biometry Audit 2012 SN60WF IOL Dr. Rose Chan
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
Phacoemulsification in eyes with previous anterior chamber phakic IOL surgery Walton Nosé, MD, PhD 1,2 Adriana dos Santos Forseto, MD 1 Mariana Ávila,
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
Reanalysis of Refractive Growth in Pediatric Aphakia and Pseudophakia Susan Whitmer, MD 1 Aurora Xu 2 Scott McClatchey, MD 1,3,4 1 Naval Medical Center.
Unilateral multifocal lens implantation in patients with a contralateral monofocal or phakic eye is a viable presbyopic correction option Robert J. Cionni,
Neeti Parikh, MD Fuxiang Zhang, MD Department of Ophthalmology Henry Ford Hospital A Comparison Of Patient Satisfaction With Modified Monovision Versus.
Hong Kong Eye Hospital Biometry Audit 2011 SN60WF IOL Dr. Rose Chan Resident, Hong Kong Eye Hospital.
Biometric Accuracy in High Hypermetropes and Myopes
Glaucoma and Penetrating Keratoplasty : Incidence, Risk Factors, and Outcomes Sonika Gupta Consultant Ophthalmology Max Eye Care New Delhi, India Author.
INTRAOCULAR LENS POWER CALCULATION BY IMMERSION A-SCAN BIOMETRY VERSUS CONTACT A-SCAN BIOMETRY MEASUREMENTS BEFORE CATARACT SURGERY Burak Bilgin**, M.D.,
Astigmatism management with toric intraocular lenses in cataract patients Adriano Guarnieri 1-2, Luis W. Lu 3-4, Alfonso Arias- Puente INCIVI, Madrid,
Cataract Extraction with Pseudoaccommodating Intraocular Lens in Patients with Previous Radial Keratotomy Ross Bloomberg, MD Niraj Shah, BS William Martin,
Jamie Ng, Marcus Tan, Lennard Thean National University Health System
A case of hypermature cataract formation following implantation of a posterior chamber phakic intraocular lens with a central hole The Catholic University.
Setting ISO Olhos – Ocular Health Institute - Uberlandia – MG - Brazil Mario J. Carvalho Giuliano O. Freitas Evaluation of “C” Limbal Relaxing Incisions.
Adriana S. Forseto1, MD Walton Nosé1,2, MD
Scheimpflug and OCT analysis of posterior keratoconus
Sherman W. Reeves, MD, MPH 1,3,4 ; Jacob A. Kozisek, OD 1,2 ; Noumia Cloutier-Gill, OD 1,2 ; David R. Hardten, MD 1,2,3,4 Accuracy of Scheimpflug Imaging.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Post-LASIK Intraocular Lens Power Adjustment Nomogram Joseph Diehl Kevin Miller, MD Jules Stein Eye Institute, David Geffen School of Medicine.
Comparison of visual function following piggyback implantation of Acrysof ReSTOR intraocular lenses with Tecnis multifocal ZM900 intraocular lenses. Rodrigo.
I have no financial interest in any devices or techniques discussed in this presentation.
Investigation of Multifocal Toric IOLs to Compensate for Corneal Astigmatism and to Provide Near, Intermediate, and Distance Vision José L. Rincón, MD.
Inadvertent Insertion of an Opposite- Side Tecnis ZM900 Multifocal IOL Wilson Takashi Hida, M.D. Celso Takashi Nakano; Jonathan Lake;
Minimizing Risk in Visian ICL Implantation.
Toric IOLs: wavefront aberrometry and quality of life Mencucci Rita Giordano Cristina, Stiko Ermelinda, Miranda Paolo, Eleonora Favuzza, Ugo Menchini Authors.
Simulated Experiments on IOL Power Calculation Using Anterior Segment OCT Dong Hyun Jo, M.D., 1,2 Mee Kum Kim, M.D., 1,2 Won Ryang Wee, M.D. 1,2 1 Department.
Dissatisfication After Multifocal Intraocular Lens Implantation in Taiwan Yu Wei Lin, MD (Presenting Author); Ching-Ju Hsieh; Lin-Chung Woung The authors.
Intraocular Lens Outcomes: Comparison of Technologies and Formulas Carolina Eyecare Physicians, LLC Research Assistant Professor of Ophthalmology Storm.
Changes of Axial Length After LASIK Surgery: A 3-Year Follow-Up Study
Poster Nr. Novel bifocal macular lens may restore reading vision in eyes with maculopathies Nicole Horchi, Hermann Anhalm, Martin Lörtscher, Carsten.
Late In-the-bag Intraocular Lens Dislocation:
Postoperative Refraction and Patient Satisfaction after Bilateral Implantation of Presbyopia-Correcting Intraocular Lenses Robert Cionni, MD Financial.
Hayashi Eye Hospital, Fukuoka, Japan
Management of Corneal Astigmatism with Toric IOLs: Optimizing Outcomes
B. Kozomara, E. Potkonjak, R. Lazic, N. Gabric
Corneal Pachymetry in Prediction of Refraction After Cataract Surgery
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation Zina Zhang MD1, Logan.
Aug 11, 2017 Comparison of predictive accuracy on Partial coherence interferometry (PCI) and swpt-source optical coherence tomographry (SS-OCT) Choun-Ki.
Effect of Axial Length Measurement Method on Refractive Outcomes of Cataract Surgery: Real World Comparison of Partial Coherence Interferometry and Immersion.
Nienke Visser, Tos T.J.M. Berendschot, Rudy M.M.A. Nuijts
MP Weikert, M Shirayama, L Wang, DD Koch
Early Experience with Descemet’s Stripping Automated Endothelial Keratoplasty Combined with Phacoemulsification: Clinical and Refractive Outcome University.
Poster Number: P90 Category: Intraocular Surgery (Cataract and Refractive) Optimization of IOL Power Calculation Constants: By Unit or by Surgeon? Nathaniel.
Comparison of Autokeratometry and Manual Keratometry
Naval Medical Center, San Diego
Eric Dai MD, Pawan Prasher MD, James McCulley MD, R. Wayne Bowman MD.
Barry A Schechter, MD Florida Eye Microsurgical Institute
IN THE NAME OF GOD.
Jonathan M. Davidorf, MD Los Angeles, CA ASCRS Annual Meeting
성모병원 안센터 CHANGES IN ASTIGMATISM RELATIVE TO IOL HAPTIC INSERTION AXIS IN WITH-THE-RULE AND AGAINST-THE-RULE ASTIGMATISM PATIENTS Hyun Seung Kim, M.D.
Factors Potentially Affecting the Accuracy of Methods to Calculate Effective Refractive Power After Keratorefractive Surgery Helga P Sandoval, MD, MSCR,
Hayashi Eye Hospital, Fukuoka, Japan
The authors have no financial interest
Visual Outcomes and Satisfaction with Toric IOL Versus Monofocal IOL
“Accommodating IOL Implantation Experience”
Michael Goodman, Alexandra Paul and Andrew Hsu
Presentation transcript:

The authors have no financial interest. Unintended Myopic Biometric Error in a Posterior Amorphous Corneal Dystrophy Patient Submitted to Anterior Segment Scheimpflug Analysis The authors have no financial interest.

Abstract One case of post-phacoemulsification refractive surprise in a posterior amorphous corneal dystrophy patient is reported herein. The refractive error´s likely causative factor, as well as our approach once it was detected are discussed in this report.

Introduction Postoperative refractive prediction is an absolutely relevant issue for the cataract surgeon1. According to an ASCRS members´ survey in 2003, inappropriate lens power selection was the most common reason for IOL explantation or exchange2. We present a case of refractive surprise for a patient with posterior amorphous corneal dystrophy (PACD) and cataract submitted to phacoemulsification and bifocal intraocular lens (IOL) implantation.

Case Report On a routine consultation, a 63-year-old female patient complained of slowly progressive blurred vision and also some perception of haloes and glare for both eyes. Manifest refraction: OD +3.00 Sph – 0.50 Cyl @ 80º (20/40) OS +3.00 Sph – 0.50 Cyl @ 105º (20/30) At slitlamp examination, both eyes showed increased mid-stromal corneal refringency, narrow anterior chamber angle and a slight-to-moderate nuclear sclerosis. No other abnormalities were detected. Cataract and PACD were diagnosed.

Case Report Scheimpflug (Pentacam/Oculus) readings: OD OS

Case Report Axial length was measured by immersion biometry (Ocuscan/Alcon). IOL power was calculated using the SRK/T biometric formula for both eyes (bifocal ReSTOR SN6AD3 IOL/Alcon). She had an uneventful procedure for her OD. But on the 7th postoperative day, the patient was unhappy with her near and distance uncorrected vision. No abnormalities were detected at biomicroscopy. Scheimpflug topographic anterior segment analysis and all biometric calculations were carefully rechecked – and confirmed. An apparently irrelevant detail gave us a starting point to our investigation: the central keratometric readings obtained from the computerized keratometer (Humphrey) were nearly 1.00 diopter steeper than those ones from Scheimpflug. This new data input, yields an IOL power calculation nearly 1.00 diopter weaker then that IOL power previously selected.

Case Report To further investigate the case, we decided to use another technology, in an attempt to assess the actual anterior corneal curvature for both eyes. We performed corneal topography based on Placido´s discs reflection (OrbscanII /Bausch&Lomb).

Case Report For the OS, IOL power was recalculated using the effective central corneal power obtained from Placido´s discs. The IOL power was then “reset” at + 24.00 diopters, 2.00 diopters weaker in comparison to the power predicted by the Scheimpflug keratometric readings. The patient had an uneventful surgery for her OS. On the 7th postoperative day, the patient was happy with her near and distance uncorrected vision (20/25 – J1 at 40 cm). The undesired myopic refraction for the OD was addressed by photorefractive keratectomy enhancement, a month later.

Discussion There is no documented explanation for such inaccurate measurements in patients with PACD by the Scheimpflug system. To our knowledge, this is the first documented case in literature describing a central corneal curvature misreading by the Scheimpflug system in a patient with PACD. In this case, keratometric measurements obtained from the Scheimpflug system lead to postoperative refractive surprise, due to a flatter “measured central corneal” power than the “actual” one. We theorize that the abnormal corneal transparency may have disrupted the Scheimpflug system from functioning properly, inducing an artifactual central corneal applanation leading to inaccurate IOL selection among for our patient. Keratometric readings from computerized keratometer and also, from Placido´s discs are not influenced by the diminished PACD´s corneal transparancy – they rely essentially on corneal reflection.

Conclusions Among PACD patients - and possibly with any other diffuse corneal opacities - Scheimpflug readings, must be used with caution for IOL power calculations1; Postoperative refraction of the first operated eye offers a valuable tool, in terms of refractive prediction for the fellow eye, in accordance to the current literature3.

References Freitas G O, Carvalho M J. Post-Phacoemulsification Refractive Surprise in a Posterior Amorphous Corneal Dystrophy Patient: Report of one Case. Under Publication Process in Rev Bras Oftalmol. Narvaés J, Zimmerman G, Stulting R D, Chang D H. Accuracy of IOL power prediction using the Hoffer Q, Holladay I, Holladay II and SRK/T formulas. J Cataract Refract Surg 2006; 32:2050-2053. Covert D J, Henry C, Koenig S. IOL power selection in the second eye of patients undergoing bilateral, sequential cataract extraction. Ophthalmology 2010; 117:49-54.

Credits . Giuliano Freitas, M.D. giuliano@isoolhos.com.br Author. . Mário Carvalho, M.D. mario@isoolhos.com.br Co-author, surgeon. . Priscila Lopo, M.D. priscila@isoolhos.com.br Co-author. ISO OLHOS – Instituto de Saúde Ocular Uberlandia – MG - Brazil www.isoolhos.com.br