OMEGA GROUND CALIBRATION

Slides:



Advertisements
Similar presentations
Good Practices of Fluorescence Spectroscopy
Advertisements

AITA 9, MERTIS Team – MERTIS Calibration, Oct 2007 Folie 1 Development of a calibration concept for the MErcury Thermal Infrared Spectrometer Thomas Saeuberlich,
Summary of Terra and Aqua MODIS Long-term Performance Jack Xiong 1, Brian Wenny 2, Sri Madhaven 2, Amit Angal 3, William Barnes 4, and Vincent Salomonson.
M3 Instrument Design and Expected Performance Robert O. Green 12 May 2005.
OL 750 Diffuse Spectral Reflectance Measurement System
Remote sensing in meteorology
1 Lites FPP-SP Performance SOT #17 Meeting, NAOJ, April Solar-B FPP As-Built Performance of the FPP Spectro- Polarimeter October, 2004 FPP Team Bruce.
1 PHYSICS Progress on characterization of a dualband IR imaging spectrometer Brian Beecken, Cory Lindh, and Randall Johnson Physics Department, Bethel.
Part IV: Optical Spectroscopy of Solids
Spectroscopy of Stratospheric Molecular O3
Absolute Photon Calibration of Zeiss Observer Z1 Microscope Shawn Miller Department of Optical Sciences University of Arizona, Tucson, AZ Optics.
In-orbit calibration (TOTAL channel) V space -V IBB Raw Earth V (counts) Raw IBB V (counts) =
0. To first order, the instrument is working very well ! 1.Evolution of the IR detector with time 2.Stability of the L channel 3.Saturation 4.Linearity.
Apr 17-22, NAOJ Dopplergram from Filtergram (FG) Observation Y. Katsukawa (NAOJ) SOT Team.
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
OMEGA DATA CUBE ORBNNNN_M.QUB Idat  S jdat sdat1 sdat0.
Spectrophotometer Prof.Dr. Moustafa M. Mohamed Vice Dean Faculty of Allied Medical Science Pharos University in Alexandria, EGYPT.
First results of the tests campaign in VISIBLE in VISIBLE for the demonstrator 12 October 2007 SNAP Collaboration Meeting Paris Marie-Hélène Aumeunier.
PACS FM-ILT SPECTROMETER SPATIAL CALIBRATION A. Contursi (H. Feuchtgruber) PACS Science Verification Review – 8/9 November 2007 MPE-Garching.
OMEGA GROUND CALIBRATION B. Gondet,Saint Louis, 21/05/2008.
NIRSpec Operations Concept Michael Regan(STScI), Jeff Valenti (STScI) Wolfram Freduling(ECF), Harald Kuntschner(ECF), Robert Fosbury (ECF)
Figure 8.Color map of the geometric correction along the dispersion axis for segment A. Figure 4. Measured distortions for all PSA positions for segment.
CDE CDR, September 14, 2004 Your Position, Your Name 1 GATS AIM Science Team Meeting January 23-24, 2007 CIPS Calibration Review, Aimee Merkel, Bill McClintock.
Optical & Radiometric Conceptual Design of EMAS Thermal Port Upgrade Kickoff Meeting June 29, 2010 Roy W. Esplin.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA MIRI VM2 Testing Scott Friedman and the MIRI Test Team (special thanks to Paul Eccleston, Alistair.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Moons of Saturn 14 October Iapetus Mimas.
SPACE TELESCOPE SCIENCE INSTITUTE Operated for NASA by AURA SMOV4 Requirements Review Cosmic Origins Spectrograph Scott D. Friedman STScI 30 July 2003.
BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE INSTITUT D’AERONOMIE SPATIALE DE BELGIQUE BELGIAN INSTITUTE OF SPACE AERONOMY BELGISCH INSTITUUT VOOR RUIMTE-AERONOMIE.
Interannual Variability and Decadal Change of Solar Reflectance Spectra Zhonghai Jin Costy Loukachine Bruce Wielicki (NASA Langley research Center / SSAI,
First Thomson Scattering Results on HSX K. Zhai, F.S.B. Anderson, and D.T. Anderson HSX Plasma Laboratory, U. of Wisconsin, Madison 1. Abstract 5. Summary.
Electro-optical systems Sensor Resolution
# x pixels Geometry # Detector elements Detector Element Sizes Array Size Detector Element Sizes # Detector elements Pictorial diagram showing detector.
Denis Tremblay 1, Yong Han 2, Yong Chen 3, Likun Wang 3, Xin Jin 2, Xiaozhen Xiong 2, Lihang Zhou 2 1 Science Data Processing Inc., 2 NOAA/NESDIS/STAR,
A. Ealet Berkeley, december Spectrograph calibration Determination of specifications Calibration strategy Note in
JWST-MIRIM (The MIRI Imager)
UVIS Calibration Update
VIRTIS –H Status Paris 10-11th May 2010 Jean-Michel REESS.
Zhouqian, Wan baonian and spectroscopy team
TEMPO Instrument Update
Relative Spectral Response and Flat Fields with Internal Calibration Lamps Luisa M. Lara IAA-CSIC Granada (SPAIN)
VIRTIS flyby of Steins M-IR Spectral analysis
Spectrophotometric calibration of the IFU spectrograph
TEMPO Instrument Update
NIRSpec simulation data-package
VIRTIS Operations at Lutetia
Calibration Activities of GCOM-W/AMSR2
AIRS (Atmospheric Infrared Sounder) Instrument Characteristics
MODIS Lunar Calibration Data Preparation and Results for GIRO Testing
Measurements of the Moon by CLARREO Pathfinder and ARCSTONE
OMEGA DATA CUBE ORBNNNN_M.QUB
Instrument Characterization: Status
Meteorological Service of Canada
Intra-pixel Sensitivity Testing Preliminary Design Review
First Assessments of EUVI Performance on STEREO SECCHI
Lunar reflectance model based on SELENE/SP data
Instrument Considerations
Detective Quantum Efficiency Preliminary Design Review
Changchun Institute of Optics Fine Mechanics and Physics
Sensor calibration.
UVIS Calibration Update
TanSat/CAPI Calibration and validation
Lecture 2 Photographs and digital mages
By Narayan Adhikari Charles Woodman
UVIS Calibration Update
Early calibration results of FY-4A/GIIRS during in-orbit testing
MAMBO PRE-LAUNCH CALIBRATION CONSIDERATIONS
Remote sensing in meteorology
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
MERIS Level 1b processing Ludovic Bourg
Presentation transcript:

OMEGA GROUND CALIBRATION B. Gondet,Saint Louis, 21/05/2008

OMEGA calibration plan Optical test bench OMEGA was mounted on a two axis platform 0.1 mrad in both site and azimuth (0.1 IFOV) Cold sink for regulating the operating temperatures light sources: - monochromator (spectraPro 275) the grating can be set as a mirror - tungsten ribbon lamp (Russia) brightness temperature from 2500 K to 2850 K five filters with different transmission profiles pinhole point source (steps of 0.05 IFOV) sample holder - black body, from 325 K to 1400 K (Galaï – 1200 BB) circular aperture covering 4 IFOV’s - grid of 4 x 4 IFOV-sized black bodies (Galileo) - cold plate, from 150 K to 293 K OMEGA calibration plan spectral calibration photometric calibration influence of detector temperature and spectrometer temperature linearity geometric calibration co-alignment, registration stray light reference targets

OMEGA IN THE CALIBRATION TANK

THE OPTICAL BENCH

Spectral calibration (lambda.dat)

List of spectral calibration performed using the monochromator SWIR (2,5 ms & 5ms) VNIR (100 &200) ms Tspectro Tdet (IR) Position in the FOV -90°C -195°C 3 -80°C center -70°C -191°C -198°C -200°C -197°C -193°C -188°C Tspectro T det (IR) Position in the FOV -90°C 20°C 5 1 (center) -80°C -195°C -70°C 3 -95°C

Procedure and examples of results for SWIR Tspectro = -90°C Tdet = -195°C Tspectro = -70°C Tdet = -195°C

SWIR-L spectral calibration as a function of position in the FOV right of FOV Nanometers left of FOV Spectel number

Spectral match between OMEGA Earth spectrum, and "MODTRAN" simulated SWIR-L SWIR-C

2. radiometric calibration mtfYYMM_25.dat (2.5 msec, release of year YY, month MM) mtfYYMM_50.dat ( 50 msec, release of year YY, month MM)

Operational parameters Hot Black body source temperature, varying from 9°C to 1175°C Cold BB temperature from 10°C down -120°C IR detector temperature from –201°C to –188°C (-195°C nominal) Integration time = 2,5 ms, 5 ms & 10ms for SWIR = 100 ms & 200 ms for VNIR Test at several positions in the FOV

DETERMINATION OF THE PHOTOMETRIC FUNCTION (C CHANNEL) low S/N 197°C 295°C 368°C 523°C saturation Signal in DN divided by the corresponding black body flux

Photometric response of OMEGA S/N ratio for observations of Mars Phase = 0°, surface temperature = 250 K Bright region Photometric response of OMEGA SWIR L SWIR C VIS Dark region Wavelength (µm) Wavelength (µm)

INFLUENCE OF THE TEMPERATURE OF THE SPECTROMETER 200 K 190 K 175 K Solid line: 5 msec Dashed lines: 2.5 msec Wavelength (µm) For OMEGA, photons remove electrons from pre-charged wells The available dynamics decreases rapidly with the temperature of the spectrometer beyond 4.5 µm, in particular for long integration times (5 msec) This is essential for the detection of sulfates

3. geometric calibration

Geometric calibration SLIT "SITE" = yaw: SCANNING MIRROR motion Point Source (ribbon lamp, grid Officine Galileo) "AZIMUTH" = pitch: spacecraft motion

Azimuth, spacecraft motion "Site", scanning mirror

Geometric calibration files IFOV for each spectel, for each of the 128 spatial directions 2. perpendicular to the slit ("azimuth") direction - for each channel, relative variation of the viewing direction along the spectrum, for each IFOV within the entire 128 px FOV - spectral registration for the 3 channels, and each of the 128 positions 3. along the slit ("site") direction - relation between the IR swath position and the VNIR column number - spectral registration for the 3 channels, and each of the 128 directions

IFOV = f(wavelength), at the center of the FOV

(Y,λ) maps of a point source scanned in azimuth SWIR-C SWIR-L 12 pixels VNIR l l l l .45 µm 1. µm 2.5 µm 5 µm

(i,j) (i,j-/+n) (i-/+m,j-/+n) IRC IRL VIS

 REGISTRATION : creation of false feature in case the viewing direction of # spectels would be as follows…  …we would end up with a misinterpretated spectral feature

REGISTRATION EFFECTS along the azimuth

4. Stray light

No stray light detected Measurements made: ± 30° ("site") ± 40° ("azimuth") Source: ribbon lamp, full power No stray light detected

5. Reference samples

Samples used: "ISM " samples "NASA" samples "Lecce" samples Source: Ribbon lamp Integration times: 2.5 ms, 5 ms, 10 ms (SWIR) 100 ms, 200 ms (VNIR) Number of files acquired : 140

Calcite Montmorillonite Gypsum Diopsite Fayelite Labradorite Magnetite wavelength (micrometers)