The authors have nothing to declare

Slides:



Advertisements
Similar presentations
1 Comparison of bitoric with monotoric laser in situ keratomileusis for the correction of myopic astigmatism with the Nidek EC-5000 Laser. By Mohamed Abdul-Rahman.
Advertisements

Quality Control in Refractive Surgery
A Prospective Trial Evaluating Scleral Rebound Tonometry Sara Duke, MD, Andrew Logeman, Shuchi Patel, MD Loyola University Chicago, Department of Ophthalmology,
Alex P. Lange The author has no financial interest to disclose.
A Prospective Trial Comparing Scleral Pneumotonometry to Goldmann Applanation Tonometry Sara Duke, MD, Usiwoma Abugo, BS, Shuchi Patel MD Loyola University.
G. Jacob 1,2, C. Bouchard 2, S. Kancherla 1. Edward Hines, Jr. VA Hospital, Hines, IL, Department of Ophthalmology 1. Loyola University Medical Center,
Effects of IOP Lowering Agents on Myopic Regression after Refractive Surgery Lim, Taehyung M.D., Hong, So Jin M.D., Cho, Beom Jin M.D., Ph.D. Chung Kyu-Hyung.
Ki Cheol Chang, MD 1, 2, Mee Kum Kim, MD 1, 2, Won Ryang Wee, MD 1,2, Jin Hak Lee, MD 2,3, Beom Seok Jeon, MD 4 Department of Ophthalmology, Seoul National.
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
ASCRS 08 Changes Of Higher Order Aberrations After Excimer Laser Treatment For Moderate Myopia by Means of Preoperative Wavefront Aberration Levels using.
P91: Clinical Performance of Phakic Angle-Supported Investigational IOL in Prospective Global Trials, ASCRS 2010, Boston P91: Clinical performance of phakic.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Clinical outcomes of Epi-LASIK : 1-Year-Long Results of Flap ON/OFF with Mitomycin-C ON/OFF Gil-Joong Yoon (MD/PhD) 1 Seong-Taeck Kim (MD) 2 Jae-Woong.
Assessment of macular thickness and function by optical coherence tomography and multifocal electroretinogram in uncomplicated cataract surgery Yang Li,
Young Joo Shin, 1 Sang Mok Lee, 2 Jin Choi, 3 Eun Ryung Han, 4 Dong Hae Kim 4 1 H ally m University Gangnam Sacred Heart Hospital 2 3The Armed Forces Medical.
LADARVision4000 Vs VISX CustomVue LADARVision4000 Vs VISX CustomVue CustomCornea CustomCornea A Comparison of Wavefront Guided Refractive Surgery outcomes.
Prevalence of Dry Eye Disease among Elderly Korean Population Sang Beom Han, MD, 1 Joon Young Hyon, MD, 1 Won Ryang Wee, MD, 2,3 Jin Hak Lee, MD, 1, 3.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
10 year follow up of LASIK surgery for low to high levels of myopia Qasim Qasem FRCS, Caitriona Kirwan MRCOpth, Michael O’Keefe FRCS. Institutional Affiliations:
Futoshi Taketani, MD,PhD,
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
Visual and IOP Outcomes after PRK in Pigment Dispersion Syndrome [Poster Number: P190] Kraig S. Bower, Denise A. Sediq, Charles D. Coe, Keith Wroblewski,
LogMAR-Analysis of multifocal intraocular lenses: Clinical performance A. Mannsfeld, I.-J. Limberger, A. Ehmer, M.P. Holzer, G. U.Auffarth International.
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Post-LASIK Intraocular Lens Power Adjustment Nomogram Joseph Diehl Kevin Miller, MD Jules Stein Eye Institute, David Geffen School of Medicine.
Wavefront-guided Ablation Retreatment in Myopic Eyes Engy M Mohamed MD, Orkun Muftuoglu MD, R.Wayne Bowman MD, V. Vinod Mootha MD, H. Dwight Cavanagh MD,PhD,
COMPARISON AND EVALUATION OF OCULAR BIOMETRY USING A NEW NON-CONTACT OPTICAL LOW COHERENCE REFLECTOMETER David Goldblum 1,3, Kaspar Rohrer 1, Rudolf Waelti.
Simulated Experiments on IOL Power Calculation Using Anterior Segment OCT Dong Hyun Jo, M.D., 1,2 Mee Kum Kim, M.D., 1,2 Won Ryang Wee, M.D. 1,2 1 Department.
Augenabteilung am St. Franziskus Hospital Münster Influence of Mydriatic Eye-drops on Wavefront-sensing and Automated Refraction Taneri S, Oehler S, MacRae.
F.I. Camesasca, MD Zeiss Invent ZO Aspheric IOL: Long-Term Results of Refractive and Aberrometric Analysis F. I. Camesasca* P. Vinciguerra.
Vinohrady Teaching Hospital, Prague, Czech Republic Vinohrady Teaching Hospital, Prague, Czech Republic M. Vokrojova MD, M. Vokrojova MD, D. Sivekova MD,
Changes of Axial Length After LASIK Surgery: A 3-Year Follow-Up Study
Magnifying Glass.
Department of Ophthalmology, University of Ulsan College of Medicine,
Epidemiology and refractive determination of astigmatism at near sight
DISCREPANCY BETWEEN PROGRAMMED AND OBSERVED DISTRACTIONS IN MAGNETICALLY-CONTROLLED GROWING ROD TREATED PATIENTS María del Mar Pozo-Balado, PhD; Noelia.
Eun Chul Kim, M.D. , Man Soo Kim,M.D.
Charlotte ROHART1, Gilles Chaine1, Damien GATINEL2
Source: Figure 1. Image of colors with their different wavelengths refracted at different angles.
Wavefront Optimized Retreatment after Prior Wavefront
Corneal High-Order Aberrations in Keratoconus
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
A Comparison of Visual Acuity, Refractive Outcomes, and Satisfaction Between LASIK Performed with a Microkeratome and a Femto Laser Nauman hashmani (MBBS),
L. Espandar, MD ; M. D. Mifflin, MD; M. Moshirfar MD, FACS
and High-Order Aberrations After Intrastromal Presbyopia Correction
Eye clinic of the 3rd Faculty of Medicine, Prague, Czech Republic
MP Weikert, M Shirayama, L Wang, DD Koch
Early Experience with Descemet’s Stripping Automated Endothelial Keratoplasty Combined with Phacoemulsification: Clinical and Refractive Outcome University.
Authors have no financial interest in any product mentioned herein
Carlos G. Arce, MD Associate Researcher and Ophthalmologist
LASIK Application in High Myopic Eyes; 10 Years Survey
The authors have no financial interest
Associate Professor of Ophthalmology
Is Photorefractive Keratectomy the Laser Vision Correction of Choice?
Preoperative Distribution of Higher Order Aberrations in Patients Undergoing LASIK Perry S. Binder, MS MD.
Sun Woong Kim, M.D.1, Hae Jung Sun, M.D.1,
Cheil Eye Hospital , Daegu, Korea
Wavefront Correction of high refractive errors
Factors Potentially Affecting the Accuracy of Methods to Calculate Effective Refractive Power After Keratorefractive Surgery Helga P Sandoval, MD, MSCR,
Lasik decentration with the VISX ActiveTrak™ System
Mohamed Abdelrahman Awadalla,FRCS Magrabi Eye Hospital Cairo - Egypt
Aspherical ablation profiles in excimer laser treatments
*Center for Excellence in Eyecare
C. Lackerbauer MD, A. Wolf MD, A. Kollias, MD, A. Kampik, MD,
Kh.P.Takhchidi, O.A. Kostin1, A.A. Stepanov1 , A.I. Ovchinnikov1.
University of California, San Diego Shiley Eye Center
Age-related difference in Lasik Treatment
Presentation transcript:

The authors have nothing to declare regarding conflicts of interest or commercial relationships. Effect of spherical aberrations on aberrometer-predicted refraction and manifest refraction Jinho Jeong1, Mee Kum Kim2, Won Ryang Wee2 Department of Ophthalmology Jeju National University Hospital, Jeju, Korea1 Seoul National University Hospital, Seoul, Korea2

Backgrounds Stiles-Crawford Effect 1937, W.S. Stiles & B.H. Crawford The directional sensitivity of the cone light passing near the edge of the pupil (a marginal ray) is less efficient at evoking sensation than light passing through the center of the pupil Works on photopic condition

Backgrounds The SCE has been reported not to act on rods and its directional selectivity is considered to be least effective in the scotopic condition. Human neurons recognize central rays more selectively according to the SCE, but on the other hand, aberrometers do not have directional selectivity. Therefore, differences between manifest refraction and aberrometer predicted refraction could occur if measurements were taken in the photopic condition. However, these measurements are usually conducted in the scotopic condition, and the SCE needs evaluation under these environments. In this study, we compared refractive errors measured by manifest refraction with those predicted by an aberrometer, both measurement types were conducted in the scotopic condition, and the role of the SCE was evaluated by analyzing correlations between spherical aberrations and discrepancies between refraction results.

Purpose Purpose: To evaluate the influence of the Stiles-Crawford effect (SCE) on manifest refraction and aberrometer predicted refraction in pseudophakic eyes. Design: Retrospective review of diagnostic tests Participants: 73 eyes of 45 patients that underwent uneventful cataract surgery.

Methods The records of 73 cases with uneventful cataract surgery were retrospectively reviewed. 1 month after surgery, manifest refraction (MR) was assessed, and ocular aberrations, aberrometer predicted refraction (APR), and mesopic pupil size were measured using a Wavescan 1 (VISX, Santa Clara, CA). APR was calculated for a 4 mm pupil. Refraction gap was calculated by subtraction APR spherical equivalents (SEs) from MR SEs, and correlations of refraction gap between high order aberration, pupil size, and refractive error were analyzed.

Results

Results Paired samples t-test: Manifest refraction - Aberrometer predicted refraction

Results The mean refraction gap was -0.28 ± 0.26 D (range -0.76 to 0.44 D), and MR SEs were significantly more myopic than APR SEs (paired t test; p<0.001). APR and MR were found to be significantly correlated with each other (R=0.963), and the distribution of the refractive gap qualified 95% limit of agreement, which ranged from -0.84 D to 0.24 D.

Results Correlations between refraction gap and refractive error, pupil size, and high order RMS. Refraction gap was measured by subtracting aberrometer predicted refraction from manifest refraction.

Results According to multiple regression analysis, spherical aberrations were significantly correlated with refraction gaps (R=0.508). As spherical aberration increased, APR became more myopic than MR. Refractive error and pupil size were not found to be significantly related to refraction gap

Discussions Schematic presentation of spherical aberration effects at a focal point. Spherical aberrations are caused by peripheral rays, and the minimum circle of confusion moves in a more myopic direction in eyes with a positive spherical aberration and in a more hyperopic direction in eyes with a negative spherical aberration. When the Stiles-Crawford effect is taken into account, central rays are more weighted and the focal point remains unchanged despite the presence of spherical aberrations.

Discussions We regard that MR with the SCE may represent the refractive state of day vision and APR without SCE represents for night vision, although some modulation may be necessary to make direct comparisons. We expect that both MR and APR results should be taken into consideration when assessing a patient’s refractive status, and these results would also be useful for deciding on ablation amounts during corneal refractive surgery in the presence of a refraction gap between MR and APR. Based on our results, we would expect a 0.4 D refraction gap for a 0.2 µm spherical aberration change.

Conclusion The Stiles-Crawford effect was found to influence manifest refraction results. In terms of the interpretation of aberrometer predicted refraction, SCE and spherical aberrations should be weighted when the relationships with MR are being investigated Both MR and APR results should be taken into consideration when assessing a patient’s refractive status