Proton Computed Tomography system: recent results and upgrade status

Slides:



Advertisements
Similar presentations
Cirrone G. A. P. , Cuttone G. , Raffaele L. , Sabini M. G
Advertisements

Sezione di Napoli Univ. “Federico II” Experimental study of beam hardening artefacts in photon counting breast computed tomography M.G. Bisogni a, A. Del.
Advanced GAmma Tracking Array
Alpha Stucture of 12 B Studied by Elastic Scattering of 8 Li Excyt Beam on 4 He Thick Target M.G. Pellegriti Laboratori Nazionali del Sud – INFN Dipartimento.
Multiplicity analysis and dN/d  reconstruction with the silicon pixel detector Terzo Convegno Nazionale sulla Fisica di ALICE Frascati (Italy) – November.
Carbon ion fragmentation study for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck base, prostate)
Optimisation of X-ray micro-tomography to perform low-dose imaging of highly-dosed gels P.M.Jenneson, E.C.Atkinson, P.Wai and S.J.Doran In 1993, Maryanski.
Vertex2002 pCT: Hartmut F.-W. Sadrozinski, SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski,
Reduced Dose of Proton CT Compared to X-Ray CT in Tissue-Density Variation Sensitivity T. Satogata, T. Bacarian, S. Peggs, A.G. Ruggiero, and F.A. Dilmanian.
Hartmut F.-W. Sadrozinski RESMDD06 Radiography Studies for Proton CT M. Petterson, N. Blumenkrantz, J. Feldt, J. Heimann, D. Lucia, H. F.-W. Sadrozinski,
RESMDD'02 pCT: Hartmut F.-W. Sadrozinski, SCIPP INITIAL STUDIES on PROTON COMPUTED TOMOGRAPHY USING SILICON STRIP DETECTORS L. Johnson, B. Keeney, G. Ross,
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Activities for Proton Computed Tomography PCT Loma Linda University Medical Center Hartmut F.-W. Sadrozinski Santa Cruz Inst. for Particle Physics SCIPP.
S. Zuberi, University of Rochester Digital Signal Processing of Scintillator Pulses Saba Zuberi, Wojtek Skulski, Frank Wolfs University of Rochester.
Vertex2002 pCT: Hartmut F.-W. Sadrozinski, SCIPP Initial Studies in Proton Computed Tomography L. R. Johnson, B. Keeney, G. Ross, H. F.-W. Sadrozinski,
Beam Test for Proton Computed Tomography PCT
Performances of a pixel ionization chamber to monitor a voxel scan hadron beam A.Boriano 3, F.Bourhaleb 2,3, R. Cirio 3, M. Donetti 2,3, F. Marchetto 3,
Xiaodong Wang ( 王晓冬 ) School of Nuclear Science and Technology Lanzhou University, Lanzhou, China MPGD activities at Lanzhou University July 5, 2013.
Applications of a Pixellated Detection System to Digital Mammography
M. Scaringella 1, M. Bruzzi 2,3, M. Bucciolini 3,4,10, M. Carpinelli 8,9, G. A. P. Cirrone 5, C. Civinini 3, G. Cuttone 5, D. Lo Presti 6,7, S. Pallotta.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Guido Haefeli CHIPP Workshop on Detector R&D Geneva, June 2008 R&D at LPHE/EPFL: SiPM and DAQ electronics.
A Single Photon Emission Computer Tomograph for breast cancer imaging S. Vecchio a, N. Belcari a, P. Bennati b, M. Camarda a, R. Campanini c, M. N. Cinti.
Test of the GEM Front Tracker for the SBS Spectrometer at Jefferson Lab F. Mammoliti, V. Bellini, M. Capogni, E. Cisbani, E. Jensen, P. Musico, F. Noto,
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
The DAMPE STK G. Ambrosi INFN Perugia. The DAMPE Detector Mass: 1480 Kg Power: 600 W Data: 16 Gbyte/day Liftime: 5 years 2.
Proportional chambers with cathode readout in high particle flux environment Michał Dziewiecki.
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
Implementation of a New Monte Carlo Simulation Tool for the Development of a Proton Therapy Beam Line and Verification of the related Dose Distributions.
Proton Computed Tomography images with algebraic reconstruction M. Bruzzi 1,2, D. Bonanno 3, M. Brianzi 2, M. Carpinelli 4,9, G.A.P. Cirrone 5, C. Civinini.
Upgrade with Silicon Vertex Tracker Rachid Nouicer Brookhaven National Laboratory (BNL) For the PHENIX Collaboration Stripixel VTX Review October 1, 2008.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Update on works with SiPMs at Pisa Matteo Morrocchi.
The PRIMA Project : development of a proton Computed Tomography system Mara Bruzzi Consuntivo PRIMA+ -CSN5 2 Maggio 2013 Roma 1 M. Bruzzi 1,2*, M. Brianzi.
1 Fisica Sanitaria, Azienda Ospedaliero-Universitaria Senese, Siena, Italy 2 INFN - Florence Division, Florence, Italy 3 Physics and Astronomy Department,
The Proton Computed Tomography Apparatus developed by INFN (RDH-WP3) M. Bruzzi 1,2, D. Bonanno 3, M. Brianzi 2, M. Carpinelli 4,9, G.A.P. Cirrone 5, C.
Attività WP8: sviluppo sistema dosimetrico INFN Firenze M. Bruzzi, M. Bucciolini, E. Pace, M. Scaringella, C. Talamonti, M. Zani, A. Baldi.
M. Bruzzi, Sviluppo di sistemi di rivelazione a silicio per imaging con protoni e dosimetria Sviluppo di sistemi di rivelazione a silicio per imaging con.
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
Algebraic reconstruction algorithms applied to proton computed tomography data M. Bruzzi 1,2, M. Brianzi 2, M. Carpinelli 3,9, G.A.P. Cirrone 4, C. Civinini.
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
The New CHOD detector for the NA62 experiment at CERN S
A General Purpose Charge Readout Chip for TPC Applications
Idee per lo sviluppo del Charge Identifier
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
1Physics Department, University of Florence, Italy
Resolution Studies of the CMS ECAL in the 2003 Test Beam
Development of a Compton Camera for online range monitoring
A new-concept Absorption Calorimeter for the ELI-NP facility
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
The interaction region for FIRST (status report)
A novel gaseous X-ray polarimeter: data analysis and simulation
AQUA-ADVANCED QUALITY ASSURANCE FOR CNAO
Panagiotis Kokkas Univ. of Ioannina
Development of a High Precision Axial 3-D PET for Brain Imaging
Towards Proton Computed Tomography
CMS Preshower: Startup procedures: Reconstruction & calibration
TIMEPIX TESTBEAM TELESCOPE FOR AIDA
HARPO, a Micromegas+GEM TPC for gamma polarimetry above 1 MeV
INFN Pisa tasks Development of a PET system
Results on Proton Tomography
Single trigger, no target
5% The CMS all silicon tracker simulation
FPGA-based Time to Digital Converter and Data Acquisition system for High Energy Tagger of KLOE-2 experiment L. Iafolla1,4, A. Balla1, M. Beretta1, P.
The Pixel Hybrid Photon Detectors of the LHCb RICH
Alberto A. Colavita, INFN, TS
MINOS: a new vertex tracker for in-flight γ-ray spectroscopy
Simulation study for Forward Calorimeter in LHC-ALICE experiment
AGATA week Uppsala, July 2008
Presentation transcript:

Proton Computed Tomography system: recent results and upgrade status M. Bruzzi1,2*, M. Bucciolini2,3, G. A. P. Cirrone4, C. Civinini2, G. Cuttone4, D. Lo Presti5,6, S. Pallotta2,3, C. Pugliatti5,6, N. Randazzo5, F. Romano4,7, V. Sipala8,9, M. Scaringella1, C. Stancampiano5,6, C. Talamonti2,3, M. Tesi1, E. Vanzi10, M. Zani2,3 1Physics Department, University of Florence, Italy 2INFN - Florence Division, Italy 3Dipartimento di Scienze biomediche, sperimentali e cliniche, University of Florence, Florence, Italy 4INFN - Laboratori Nazionali del Sud, Catania, Italy, 5INFN - Catania Division, Italy 6Physics Department, University of Catania, Catania, Italy 7Centro Studi e Ricerche e Museo Storico della Fisica, Rome, Italy 8Chemistry and Pharmacy Department, University of Sassari, Sassari, Italy 9INFN Cagliari Division, Italy 10 SOD Fisica Medica, Azienda Ospedaliero-Universitaria Careggi, Firenze, Italy * Spokesperson M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Outline Introduction: proton therapy and proton imaging Proton imaging apparatus Tracker Single module architecture Detector VLSI front-end Calorimeter Crystal YAG:Ce Electronic readout Trigger system First results with proton beam Conclusions M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Proton therapy The proton therapy is a good clinical treatment for cancer as it permits to obtain a dose distribution extremely conform to the target volume. The Bragg peak shape ensures that healthy tissues in front of and beyond the tumor are not damaged. Through the weighted superposition of proton beams of different energies it is possible to deposit a homogenous dose in the target region using only a single proton beam direction. (Spread Out Bragg Peak -SOBP). M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

proton Computed Tomography: why? In proton therapy treatments is important to know: Patient positioning: Currently performed using X-rays radiography in previous phase pCT allows better accuracy and single phase positioning / treatments Dose Calculation: Currently performed using X-rays computed tomography Problem: protons and photons have different interaction with matter pCT uses protons directly for dose calculation The error intrinsic in this conversion (due to e,Z) dependency on atomic number and electron density) is the principal cause of proton range indetermination (3%, up to 10 mm in the head)‏ [Schneider U. (1994), Med Phys. 22, 353]

Parameters of pCT Problem: protons, because the multiple Coulomb scattering, don’t move in straight line. M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

THE “PRoton IMAging (PRIMA) PROJECT” pCR apparatus oriented to pCT PROGRAM Design and manufacture a high-performance prototype for proton radiography and tomography. Develop suitable imaging algorithms; Validate the pCR/pCT system with pre-clinical studies Conceive an upgraded prototype for pre.clinical studies - Hardware and data acquisition; - Reconstruction algorithms. M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Concept proton Computed Radiography and Tomography z x y proton Computed Radiography and Tomography Reveal the track of the single proton using a silicon telescope Measure the residual energy of the proton using a calorimeter Reconstruct the most likely path of the single proton pCR for different projections with a rotating gantry Single event information can be processed by reconstruction algorithms to produce tomographic images. M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Architecture of the pCT apparatus M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Tracker module architecture To achieve a read-out rate of 1 MHz a fully parallel digital strip readout system has been developed Eight 32-channel VLSI front-end chips acquire the detector signals and sends data in parallel to an FPGA (Xlinx Spartan-3AN) which performs zero suppression and moves data to a buffer memory (~5x105 events). An Ethernet commercial module is use both for data transfer to the central acquisition PC and to control the tracker module DAQ parameters M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Silicon strip detector Manufactured by Hamamatsu Photonics 53x53 mm2 p+-on-n strips 256 ch, 200 m pitch 200 m thickness (To reduce the multiple scattering in the detector while keeping a good sensitivity to protons) Vfd = 65-75V M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy 10 10

VLSI front-end description AMS 0.35u CMOS Technology 1.6 mm x 6 mm 32 channels Power dissipation = 14,5 mW @ chan Vcc = +3.3 V M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Calorimeter YAG:Ce properties 4 YAG:Ce scintillating crystals Each crystal 30 x 30 mm2 x 100mm 4 Photodiode 18 mm x 18 mm 4 commercial front-end (Charge Sensitive Amplifier & shaper ) YAG:Ce properties PHYSICAL PROPERTIES Density [g/cm3] 4.57 Hygroscopic No Chemical formula Y3Al5O12 LUMINESCENCE PROPERTIES Wavelength of max. emission [nm] 550 Decay constant [ns] 70 Photon yield at 300k [103 Ph/MeV] 40-50 M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

pCT system designed and manufactured by the PRIMA INFN CSN5 collaboration Entry and Exit position and direction 4 x-y TRACKER MODULES 1 CALORIMETER Residual Energy M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

First tests: one x-y plane with YAG:Ce calorimeter (I) INFN LNS p 60MeV GOAL: to test the functionality of the architecture. A x-y tracker plane has been coupled with the calorimeter. The test has been performed at LNS with 60MeV proton beam. Collimator was used ( Ø 5mm ). Rate 1-50kHz Counting map ( 1 crystal not connected) Data projection M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Correlation between tracker and calorimeter data First tests: one x-y plane with YAG:Ce calorimeter (II) INFN LNS p 60MeV Correlation between tracker and calorimeter data  collimator removed from the beam pipe Map of events triggered by crystals II (red) and IV (black) Data projection Good correlation ! M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

First tests: Complete apparatus INFN LNS p 60MeV Alignment test Radiography of a non homogeneous phantom radiographies at different angles for first tomographic reconstruction Calorimeter Tracker: 4 x-y planes Beam M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

First tests: Radiography of a walnut INFN LNS p 60MeV M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

First radiography tests with complete apparatus INFN LNS p 60MeV P1 P2 P3 P4 x y One cluster in each plane Cut on difference between “entrance“ and “exit” angles Sigma=0.170 ± 0.09mm FWHM = 0.400± 0.212mm Residual energy (MeV) M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Pmma cylindrical phantom with holes First radiography tests with complete apparatus Svedberg Laboratory Uppsala p 180MeV Pmma cylindrical phantom with holes 14 cm total thickness Not to scale Hole thickn. (cm) 1 1,5 2,3 3,3 4,5 6 8 10 pCT prototype mounted on 180 MeV protons beam line Radiography without filtering M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

First Tomography tests with complete apparatus INFN LNS p 60 MeV PMMA phantom: diameter 2 cm, height 4 cm – holes f 4&6 mm, length 2 cm 36 projections (10 degrees steps) 2 cm M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Unknown stopping power distribution (at E0) Data Analysis: Tomographic equation E. Vanzi et al. PRIMA collaboration: preliminary results in FBP reconstruction of pCT data - 12 October 2012 - RESMDD12 Conference Definition of the tomographic equation (Wang, Med.Phys. 37(8), 2010: 4138) «projection» Unknown stopping power distribution (at E0) Evaluation of the “projection” term (through numerical integration starting from NIST tables and using the measured Eres) Eres Wang projection Corresponding Wang projections Mean measured residual energy plotted at P3 plane Vanzi E. et al. The PRIMA collaboration: preliminary results in FBP reconstruction of pCT data, in press on Nucl. Instrum. Meth A. M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Data Analysis: Rebinning We defined a plane parallel to detector’s planes passing through the phantom axis. Plane is sampled in a 256 x 256 matrix, 200µm pixel size. For each event, associated projection bin is determined by the intersection of the line connecting P2 and P3 impact points with the plane. P2 P3

Tomographic reconstruction: first results E. Vanzi et al. PRIMA collaboration: preliminary results in FBP reconstruction of pCT data - 12 October 2012 - RESMDD12 Conference Tomographic reconstruction: first results Butterworth filter: order 2, cut-off 20/128 of the Nyquist freq. Good quality images without cuts: possibility of reducing acquisition times and dose in patient procedures Vanzi E. et al. The PRIMA collaboration: preliminary results in FBP reconstruction of pCT data, in press on Nucl. Instrum. Meth A. M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Mara Bruzzi Riunione RDH 22 Aprile 2013 Roma Resolution Evaluation The edge of the phantom is fitted with an erf function on 20 slices in the homogeneous region. The derivative of the erf function is a Gaussian function that describes the Line Spread Function (LSF) of the imaging system. FWHM=0.9±0.1mm Noise=2.4% The mean FWHM of the LSF over the 20 slices was evaluated and used to quantify resolution. Mara Bruzzi Riunione RDH 22 Aprile 2013 Roma

Upgrade: the pre-clinical prototype A new prototype based on the same technology, to meet pre-clinical demands now under development Increase 4x of the active area On-line data acquisition Data rate up to 1 MHz Rectangular shape to perform tomography in slices Tracker: X1 FE X2 FE X3 FE X4 FE top 4x1 silicon detectors 5x20 cm2 active area Calorimeter: 7x2 YAG crystals 6x21 cm2 active area Scaringella M. et al. The PRIMA collaboration:, in press on Nucl. Instrum. Meth A. M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Upgrade: the upgraded calorimeter 7x2 YAG:Ce scintillating crystals 30 x 30 mm2 x 100mm each. Photodiodes assembled . Now under test (RDH) M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy

Conclusions A pCT apparatus has been designed and built by the PRIMA Collaboration INFN CSN5 based on: Silicon microstrip detectors 5x5 cm2 active area YAG:Ce cristal calorimeter The prototype has been tested under proton beams with energies up to 180 MeV with promising results. First tomographic images were reconstructed with FBP with encouraging results. Even using the information on two planes only and without cuts on events good quality images were obtained. A new prototype with larger area (5x20 cm2) is under development for pre-clinical validation. Future progress in WP3 RDH Project INFN CSN5. M. Bruzzi,, International Nuclear Physics Conference INPC2013: 2-7 June 2013, Firenze, Italy