Integration Bacnet Server HDL-BN-4096.

Slides:



Advertisements
Similar presentations
2006/12/05ICS Home Automation Examples of WSN: (iPower: An Energy Conservation System for Intelligent Buildings) Yu-Chee Tseng (appeared in ICS 2006)
Advertisements

Foreseer® Server Editing
SV100 Open-Loop Vector VFD FV100 Closed-Loop Vector VFD 1.
Module 4: Analog programming blocks. Module Objectives Analyze a control task that uses analog inputs. Connect a potentiometer to LOGO! controller and.
“Power Supply” Controls Voltage Difference in Voltage is set Output Current is “as requested” by attached device.
Show Controller——DMX Module 48 Channel——SB-DN-48DMX 512 Channel——SB-DN-512DMX Configuration of Show Control ler ( DMX Module ) 240 Channel——SB-DN-240DMX.
BACnet and Lighting Applications The photographs used in this presentation were taken by Steve Karg. This presentation was created and edited with OpenOffice.org.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
Introduction Mobile Switch is a device which will be helpful to switch on and off any electrical/electronic devices through a SMS. The parameters of these.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Computer Literacy for IC 3 Unit 1: Computing Fundamentals © 2010 Pearson Education, Inc. | Publishing as Prentice Hall.1 Chapter 1: Identifying Types of.
Introduction to PIC-C. Required Software PIC-C Compiler Firmware Downloader Driver for the USB->Serial Adapter.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
Programming Software and Setting. if forget the IP address of SB-DN-1IP, programmer can press the reset button till the led goes red, then it is reset.
1 Outline Firmware upgrade of the HV_LED_DAC boards. HV Status Bits board. Status of the board integration into the LHCb TFC system. CALO HV system and.
Dimmer debugging Big dimmer ( hanging dimmer ) ◆ 12ch 10A professional Intelligent Dimmer ◆ 6ch 20A professional Intelligent Dimmer ◆ 6ch 10A professional.
User Interface – Switch Panel 6 Gang Switch Panel Configuration guide RS485 Terminal Fixing hole Bayonet Front ViewBack View.
DMX Controller SB-DN-512DMX.
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
HDL KNX System Introduction
TOUCH Life SB-WL-TL7 SB-MBL-TS10-CE Windows XP. Touch screen function manual Click the icon 5 times to exit Room select key Room Function Icon function.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
MRDA Wiring diagram S-BUS Module ID setting button ballast L N DC0-10V dimming voltage Control DC Maximum current :100mA 6 relay switch 16A 6 channel.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Curtain Controller SB-DN-2Motor. SB-DN-2Motot is a professional two curtains(shutters) controller. The curtain module can control the curtain by AC motor.
Control Output Devices Hyper linking. Back to Input Devices Back to Input Devices What Are Control Output Devices? These are devices that are associated.
Detect Range : 5×5m Detect Angle : 110 Degree Bus Port : HDL-BUS(485bus) Detect distance( sensitivity ): Adjustable via Software, from 1 to 100 Dimension.
6 CH 5A LED Dimmer HDL-MDLED /2/2016 Description HDL-MDLED CH 5A Intelligent LED Dimming Module, it can be used to control the LED.
Air-Condition controller
Integration AC System.
Gateway HDL-MBUS01IP.431.
DALI Scene Controller HDL-MC-DALI.431.
DALI Scene Controller HDL-MC-DALI.431.
DIN Rail Music Player HDL-MZDN.432A.
Multifunctional Sensor
ILife App.
SB-DN-Logic960 Logic module.
6 CH 5A LED Dimmer HDL-MDLED
SMS module HDL-MGSM.431.
FLoor Heating Controller
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
Universal connection and monitoring for M2M applications
Pilot Watcher Product Overview V5.3
Wireless Relay HDL-MPR01-RF.18.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
C without OMMERCIAL PRODUCT Without Product
DMX Controller SB-DN-48DMX.
SCADA for Remote Industrial Plant
FLoor Heating Controller
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
Wireless 3 Buttons Touch Panel
Wireless Gateway HDL-MCIP-RF02.10.
RS232 Converter SB-DN-RS232N.
Wireless Relay HDL-MPR02-RF.18.
Progress Updates: ICP DAS ET-7026 Communication & CryoBLM analysis
Chapter 10: DHCP Routing & Switching Chapter 10: DHCP
Pilot Walktour Operation Guide V3.4 (Android)
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Curtain Motor HDL-MWM70B.12 HDL-MVSM45B.12.
2500 Series® Compact System Components
Chapter 1: Computer Systems
2500 Series® Compact System Components
Status of Fast Controller EPICS Supports for ITER Project
Examining IP Addressing
HOW PROTOCOL GATEWAYS GET CONFIGURED
Total HVAC Control from anywhere Easy control that can save a fortune
Presentation transcript:

Integration Bacnet Server HDL-BN-4096

Introduction HDL-BN-4096, only need to use the special firmware to upgrade the SB-DN-1IP or HDL-MBUS01IP.431. It builds in the bacnet protocol, allows BA and BMS system to monitor and control HDL system, like lighting, HVAC, floor heating, etc. Note: HDL devices should be configured by HDL buspro software when controlled by Bacnet System. Open the HDL buspro software, search and set parameters of the HDL-BN-4096 And HDL can also control Bacnet AC system. You can refer to another PPT (Integration_AC System)

System connection

Basic Information The Bacnet server default IP is 192.168.10.252.

Configuration 1.Bacnet has different type: AI, AO, AV, BI, BO,BV, MI, MO, MV, Other. Different type can control different targets. 2. The Bacnet ID is generated automatically according to the Bacnet ID type and ID value. 3. Type of control target. It is the HDL control type. 4. ID of HDL devices

Bacnet Objects AI: Analog Input AO: Analog Output AV: Analog Value, used to define start-stop commands of devices BI: Digital Input (Binary Input) BO: Digital Output (Binary Output) BV: Digital Output (Binary Value), used to define start-stop commands of devices MI: Multi State Input MO: Multi State Output MV: Multi State Value

Application Control the CH3 of HDL dimmer: Setting in HDL Buspro software

Application Setting in Bacnet Explorer PS: Type 100: it means turn on the channel 0:it means turn off the channel