Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: PROOSIS engine schematic diagram
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: Local adaptation procedure
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT data used for adaptation and diagnosis
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: Health factors RMS for calibration data (full load and part load)
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: Health factors RMS versus corrected speed
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: Procedure for calculating power output and heat rate deterioration
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 relative performance parameters
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 compressor health factors
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 turbine health factors
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 Qexh versus IGVs angle
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 combustor outlet temperature and TITREF versus power output
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 PR versus W2,cor
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 relative power output and compressor efficiency
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 relative corrected power output
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GT1 compressor health parameters and performance deterioration
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GTs performance deterioration for February 2013 and 2014
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GTs performance deterioration for August 2013 and 2014
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: Power plant performance gain due to on-line washing routine
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: Power profile for the three washing strategies (reference, equidistant, and optimized intervals)
Date of download: 12/27/2017 Copyright © ASME. All rights reserved. From: Industrial Gas Turbine Health and Performance Assessment With Field Data J. Eng. Gas Turbines Power. 2016;139(5):051202-051202-10. doi:10.1115/1.4034986 Figure Legend: GTs deterioration rate during 2014