Curtain Actuator M/W02.10.1.

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

Operating Functions.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
Memmert Oven (in yellow room) The door is opened by pulling the door knob, and is closed by pushing in the door knob. Control module /display Control module.
Calibration Procedure.  A winch calibration is completed via a linear interpolation between 2 points.  Requires 2 references  Known lower weight 
AccuMax Multi-Point Injection Mechanics
MDS Smart Commander.
Wireless Remote Controller (MR-AH01/BH01) HQ SE.  On/Off control  Air flow control  Temperature setting  Filter reset  Louver Control  Simple ON/OFF.
Building Control with KNX Education - Schools. Schneider Electric 2 - IS&C - GPatt – School’s classroom Manage according to external conditions.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
SB-DN-SEC250K security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm. Addressing button HDL -BUS.
HVAC Wiring diagram 5 channel output (5A relay) Speed: High/Medium/Low Mode: Cooling / Heating /Dehumidifier HVAC is a module specially for Air Conditioner.
DMX Controller SB-DN-512DMX.
Service Section Technical Training December 2005.
SB-DN-HVAC (MAC01.331) Air-Condition controller.
SB-DN-Logic960 Logic programmer / timer. Description  SB-DN-Logic960 is an intelligent programmable logic controller, it can control the system automatically.
Buspro Wireless Last update: April 10, HDL-MCIP-RF.10 Connections: Buspro, Ethernet, Buspro wireless Work Mode: Mesh mode or Bridge mode Wireless.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Solutions for Hotel HDL-MHRCU.431.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Curtain Controller SB-DN-2Motor. SB-DN-2Motot is a professional two curtains(shutters) controller. The curtain module can control the curtain by AC motor.
QCR8 = CQ806F Full Function Two-Page Color Quad Processor USER MANUAL.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
DATE Manual DS – DVR Tel : 82–32-462–6911
 Introduction  Problem  Solution  Future work.
6 CH 5A LED Dimmer HDL-MDLED /2/2016 Description HDL-MDLED CH 5A Intelligent LED Dimming Module, it can be used to control the LED.
shift to the Test Mode (Forced Operation).
ABB i-bus® EIB Shutter Actuators
Air-Condition controller
User Operation Presentation
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX i-bus® Tool
DALI Scene Controller HDL-MC-DALI.431.
DALI Scene Controller HDL-MC-DALI.431.
Wireless Power Interface
Room Controller RC/A 8.1 Room Controller economic flexible modular.
Multifunctional Sensor
SB-DN-Logic960 Logic module.
6 CH 5A LED Dimmer HDL-MDLED
SMS module HDL-MGSM.431.
FCU Controller M/FCU
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
FLoor Heating Controller
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
Dimmer 6fold 10V Actuator M/DA
Security module SB-DN-SEC250K.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Conveyor Belt Production Line
Blower-/Fan Coil-Actuator
Universal Interface, 4-fold, FM, US/U 4.2
ABB i-bus® KNX The new Room Master RM/S 3.1 and RM/S 4.1
Pneumatics Module 9 Time delay valve.
FLoor Heating Controller
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
2N® Access Unit Touch Keypad
DMX512 Gateway M/DMX512.1.
Wireless 3 Buttons Touch Panel
MOSFET Dimmer Actuator
MPU-16A / FPU-16 TEST UNIT TUTORIAL
Curtain Motor HDL-MWM70B.12 HDL-MVSM45B.12.
BRC1E61 – Energy Saving Function
Light Trails and light painting
Voyager II and III – Energy Recovery Modules
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
Flotection: Building Main Shutoff System
Universal Dim Actuator UD/S
Operation of Target Safety System (TSS)
Table of contents Getting started Panel configuration with Eldes Utility Tool Setting automation parameters Practical examples.
F3SG-4SR Series Light Curtain: A new standard in machine safety
Presentation transcript:

Curtain Actuator M/W02.10.1

Curtain Introduction The curtain actuators use 10A relay for switching forward, reverse or stop on every output channel and each channel has a bypass button for manual control. The functions include Blinds mode, Curtain mode, Priority setup, Forced position operation, Limit position control, Status response for position, Status for operation, Scene control, Safety control, and Automatic control

Wiring The bypass button is for manual control, up/down and adjust position. Keep long pressing it, the curtain will move to the fully open/close position. after reach the end, long press it again to adjust the curtain.(after installed it, use to adjust the curtain real position to sync the curtain module position) shutter: short press, no action blinds: short press, adjust louver

Priority setup Work with the weather sensor which can detect the wind, rain, frost, then control the curtain moving to the safe position. Set the priority of these weather conditions, when the sensor detected more than one conditions, it will execute the action of the first priority condition. You can enable/disable the weather conditions here.

Moving time operation mode: shutter- fot normal curtain, open/close/stop control blinds- for the curtain which has the louver, open/close/stop control and louver adjust moving time: user needs to test the curtain's moving time then set the time value here

Alignment Start up time: set the delay time for curtain to move when receives the up/down command Alignment: the alignment time to sync the curtain real status and the module status, after installed the curtain, will need to use this function, after that, normally no need to use it.

Control setting use 'move shutter up/down' and 'stop moving' objects to control the curtain running, assign two group addresses for them, shown in the above picture. move shutter up/down- receives 1, will move up; receives 0, will move down. stop moving- no matter receives 0 or 1, will stop moving

Pannel setting

Q1: For weather alarm, how could curtain module get the state of wind, rain and frost? Surely a special sensor need to be used, what are those sensors? A1: HDL does not have such type of sensor that can detect the wind/ rain/ frost for the time being(will develop it in the future), you can look for this sensor on the market yourself. Q2: We can preset 4 positions in position function page, when do we need to use this function? A2: This four positions normally use with auto control function, when the sensor detects different lux/ temperature, will move to different positions(position1/2/3/4) according to your settings.

Q3: There are two options “set positon” and “move to positon” in position function page, how to use these functions? A3: Set position: There are 4 preset positions in database, user can use button to change these values via this object. If the object “set position1/2” receives 0, current position will replace position1, if receives 1, current position will replace position2; If the object “set position3/4” receives 0, current position will replace position3, if receives 1, current position will replace position4. Move to position: you can manually control the curtain to these four preset positions. If the object “move to position1/2(3/4)” receives 0, will move to position 1(3); if receives 1, will move to position 2(4).

Q4: It‘s hard to understand some descriptions in auto pages, heating, cooling, sun. And how can the curtain module can get these states? A4: For auto control function(auto1/ auto2), need to use sensor to detect lux("sun" in database) / temperature("cooling/heating" in the database). sun=0, low lux; sun=1, high lux. cooling=1, low temp; heating=1, high temp. For low or high value, according to your settings in sensor. Q5: There are 3 options called forced operation1, 2, 3 and also exit forced operation, what do they mean? A5: Force position has the highest priority control right, if you use this function, need to exit it before you do another control(2 bit: 10 up; 11 down; 00/01 exit. 1 bit: 1 specific position; 0 exit). Normally no need to use it.