Signal Formation & Timing in Conventional P-I-N Diodes

Slides:



Advertisements
Similar presentations
of Single-Type-Column 3D silicon detectors
Advertisements

IAP-PAI 25/05/20051 CMS Si Rad. Hardness Introduction Damage in Si Neutron tests => Beam => Irrad. Setup.
Trapping in silicon detectors G. Kramberger Jožef Stefan Institute, Ljubljana Slovenia G. Kramberger, Trapping in silicon detectors, Aug , 2006,
Hartmut Sadrozinski US-ATLAS 9/22/03 Detector Technologies for an All-Semiconductor Tracker at the sLHC Hartmut F.W. Sadrozinski SCIPP, UC Santa Cruz.
RESMDD'02 pCT: Hartmut F.-W. Sadrozinski, SCIPP INITIAL STUDIES on PROTON COMPUTED TOMOGRAPHY USING SILICON STRIP DETECTORS L. Johnson, B. Keeney, G. Ross,
RSH Front End Electronic R. Beaujean, S. Böttcher Kiel Nov 07, 2005.
Ultra-Fast Silicon Detector 1 This report is a summary of what was shown at IEEE. Nicolo Cartiglia, INFN, Torino - UFSD - Timing Workshop CERN 2014 Nicolo.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
TOF at 10ps with SiGe BJT Amplifiers
Chapter 6 Photodetectors.
4/11/2006BAE Application of photodiodes A brief overview.
Semiconductor detectors
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Hartmut F.-W. Sadrozinski,Beam Test of LGADs, 10th Trento, Feb Beam Test of LGADs Hartmut F.W. Sadrozinski with Astrid Aster, Vitaliy Fadeyev, Patrick.
3/26/2003BAE of 10 Application of photodiodes A brief overview.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
X-ray radiation damage of silicon strip detectors AGH University of Science and Technology Faculty of Physics and Applied Computer Science, Kraków, Poland.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
A. Rivetti Gigatracker meeting, dec 2009 Charge measurement with the TDC per pixel architecture A. Rivetti, G. Dellacasa S. Garbolino, F. Marchetto, G.
Time Resolution of Thin LGADs Results from the Nov 2014 Beam Test at CERN Improvement in hand: Sensor Capacitance Measurements with  Front TCT 1 Hartmut.
June 1-5, Santa Fe N. M. Vertex Ultra-fast Silicon Detectors June 3, 2015 Abe Seiden UC Santa Cruz.
Evaluation of electron and hole detrapping in irradiated silicon sensors Markus Gabrysch 1, Mara Bruzzi 2, Michael Moll 1, Nicola Pacifico 3, Irena Dolenc.
Ultra-Fast Silicon Detector 1 Aide memoire: we are exploring the possibility of using silicon detectors with moderate gain to achieve ~ 20 ps time resolution.
Ultra-Fast Silicon Detectors (UFSD)
HO #3: ELEN Review MOS TransistorsPage 1S. Saha Long Channel MOS Transistors The theory developed for MOS capacitor (HO #2) can be directly extended.
1 Nicolo Cartiglia, INFN, Torino - RD50 - Santander, 2015 Timing performance of LGAD-UFSD 1.New results from the last CNM LGAD runs 2.A proposal for LGAD.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
Experience with 50um thick epi LGAD
SIAM M. Despeisse / 29 th January Toward a Gigatracker Front-end - Performance of the NINO LCO and HCO Matthieu Despeisse F. Osmic, S. Tiuraniemi,
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
T. Lari – INFN Milan Status of ATLAS Pixel Test beam simulation Status of the validation studies with test-beam data of the Geant4 simulation and Pixel.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
Celso Figueiredo26/10/2015 Characterization and optimization of silicon sensors for intense radiation fields Traineeship project within the PH-DT-DD section.
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
Development of radiation hard Sensors & Cables for the CBM Silicon Tracking System Sudeep Chatterji On behalf of CBM-STS Collaboration GSI Helmholtz Centre.
Time Resolution of UFSD 1 Hartmut F.-W. Sadrozinski, UFSD Timing RD50 Hartmut F.-W. Sadrozinski Z. Galloway, B. Gruey, H. Grabas, Z. Liang, S. N. Mak,
Proposal of a digital-analog RPC front-end for synchronous density particle measure for DHCAL application R.Cardarelli and R.Santonico INFN and University.
Charge Multiplication Properties in Highly Irradiated Thin Epitaxial Silicon Diodes Jörn Lange, Julian Becker, Eckhart Fretwurst, Robert Klanner, Gunnar.
CERN PH MIC group P. Jarron 07 November 06 GIGATRACKER Meeting Gigatracker Front end based on ultra fast NINO circuit P. Jarron, G. Anelli, F. Anghinolfi,
Infrared Laser Test System Silicon Diode Testing 29 May 2007 Fadmar Osmić Contents: Setup modifications new amplifier (Agilent MSA-0886) new pulse generator.
Ultra-Fast Silicon Detector 1 The “4D” challenge A parameterization of time resolution The “Low Gain Avalanche Detectors” project Laboratory measurements.
Timing capabilities of Ultra-Fast Silicon Detector 1 A parameterization of time resolution A program to calculate Time resolution UFSD Timing capabilities.
Picosecond timing of high energy heavy ions with semiconductor detectors Vladimir Eremin* O. Kiselev**, I Eremin*, N. Egorov***, E.Verbitskaya* * Physical-Technical.
Ultra-Fast Silicon Detector 1 This report is a summary of what was shown at IEEE. Nicolo Cartiglia, INFN, Torino - UFSD - RD50 CERN 2014 Nicolo Cartiglia.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Application of photodiodes
Design consideration on thin LGAD sensors
Radiation damage studies in LGAD detectors from recent CNM and FBK run
Electronics & Communication Engineering
Simulation of the Time Response of a VPT
HEC I chip design Short summary (J.Bán).
Characterization and modelling of signal dynamics in 3D-DDTC detectors
Results achieved so far to improve the RPC rate capability
First production of Ultra-Fast Silicon Detectors at FBK
Charge collection studies with irradiated CMOS detectors
Position Sensitive TCT Measurements with 3D-stc detectors
HG-Cal Simulation using Silvaco TCAD tool at Delhi University Chakresh Jain, Geetika Jain, Ranjeet Dalal, Ashutosh Bhardwaj, Kirti Ranjan CMS simulation.
Hartmut F.-W. Sadrozinski, UFSD, 28th RD50 Meeting
Radiation Damage Studies for Solid State Sensors Subject to Mrad Doses
Photodetectors.
Ultra-fast Silicon Detectors Hartmut F.-W. Sadrozinski
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Radiation Damage in Silicon
Simulation of signal in irradiated silicon detectors
Time-sensitive CMOS MAPS
CCE measurements with Epi-Si detectors
Semiconductor Detectors
Solid State Electronics ECE-1109
Why silicon detectors? Main characteristics of silicon detectors:
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

Signal Formation & Timing in Conventional P-I-N Diodes Hartmut F.-W. Sadrozinski SCIPP UC Santa Cruz, CA 95064 USA Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Constraints for precision timing from sensors (currents) from pre-amplifier (voltages) Noise and pulse shaping in Broad-Band amplifiers Simulations of Pulse shapes with Weightfield 2 (WF2) Pivotal role of detector capacitance Case study: Simulation of recently reported MIP timing measurements

A time-tagging detector For calorimeter applications, the sensors are un-segmented n-in-p pads with Cd=A/w. (Area =L2 , thickness w) Will consider a broad-band pre-amplifier (BB) which contributes the input impedance (e.g. R=50Ω) to the crucial time constant R*Cd. The discussion of the time measuring circuit is left to experts like Christophe. Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Timing error: The pulse slew-rate (slope) dV/dt is the critical parameter for timing consideration For signals of many MIPs, only jitter σj = Noise/(slope) is relevant if the time measuring circuit is under control. Note that for N concurrent MIPs, the jitter is σj (N) = 1/N* σj (MIP) The is the “root cause” for the good timing resolution in calorimeters.

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Noise and Signal in an Broad Band Amplifier (BB) With a charge sensitive amplifiers (CSA), aka a “Capacitor”, the output signal does not depend on the detector capacitance Cd , but the noise does. With a broad-band amplifier (BB), aka a “resistor”, it will be shown that the signal height depends on Cd via the R*C at the amplifier input and that the noise is independent of the capacitance, as measured with a bias scan of the sensor. The amplifier noise is crucial parameter, since it causes the time jitter, which can be the dominant part of the timing resolution. Jitter = Noise/slope = Noise /(dV/dt) Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016

Thin vs Thick detectors + - i(t) Thin detector Thick detector S tr Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Ramo’s Theory predicts the detector current (the weighting field Ew =1/d for pads): The current is proportional to the sum of the velocities of all moving charges. Highest at t=0 when all charges all still moving, and v is saturated. Lower if the bias is too low such that there is a velocity gradient.

Charge Collection Time in Si Sensors Drift velocity saturates for both electrons and holes! -> need thin sensors or large over-depletion for fast charge collection Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Collection time is close to minimum when E-Field ≥ 20 kV/cm For 300um Si Collection time ~ 4 ns (h), ~ 3 ns (e) For 50um Si Collection time ~ 0.7 ns (h), ~ 0.5 ns (e)

Nicolo Cartiglia, INFN, Torino - 13 June 2016 Sensor: Simulation Nicolo Cartiglia developed a full sensor simulation to optimize the sensor design WeightField2, F. Cenna, N. Cartiglia 9th Trento workshop, Genova 2014 Available at http://personalpages.to.infn.it/~cartigli/weightfield2 It includes many “bells & whistles” required for the detailed description of the signals, i.e. charge generation, drift and collection. It allows to separate the properties of the current source from the amplifier shaping. (Perfect to teach and learn about silicon sensors) Nicolo Cartiglia, INFN, Torino - 13 June 2016

WeightField2: the Silicon Detector Simulator Nicolo Cartiglia, INFN, Torino - 13 June 2016

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 The Current Source: Current from 10 MIPs In the following simulate the signal from 10 MIPs Total current = electron current + hole current Drift time difference electrons-holes clearly visible Most importantly: The current peaks at t=0 where we want to make the time measurement Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 The current signal of sensors with different thickness’ show that the height of peak at t=0 is independent of the detector thickness! Thick detectors contribute to the tail. The 300µm sensor is not sufficiently over-depleted to reach saturation velocity, in contrast to the thinner ones. Simulations by Charilou Labitan

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 WF2 : Radiation Effects on Signal Current Radiation damage are increase of leakage current and trapping (loss of charge). Since trapping is characterized by a characteristic time of ~50ps (and thus a characteristic distance of ~50µm at saturated drift velocity) only the later part of the pulse is affected which is not used for timing (unless TOT is used!). The current maximum at the pulse front is preserved. A pulse from 300µm sensor resembles one from a 50µm sensor after a fluence of several 1015 neq/cm2 High bias operation is preferred to decreased the drift time. Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Niamh Maher Simulations by Chiara Baldassarri & Niamh Maher

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 WF2: Radiation Effects on Voltage Pulse Shape Assume BB amplifier with 50Ω input impedance and gain of 100. Vary: pad size A: 1x1, 3x3, 5x5 mm2.sensor thickness w:100µm, 300µm This samples different detector capacitance Cd-= A/w from 0.3 to 40pF Solid State Physics convolution Electronics Current RC → Voltage → Radiation effect Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 100µm RC RC 300µm Simulations by Charilou Labitan

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 WF2: Radiation Effects on Voltage Pulse Shape The pulse height varies both with the detector capacitance and the radiation Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 The slew-rate (20% - 80%) depends universally on detector capacitance e.g. dV/dt(5mm/300µm) ≈ dV/dt(3mm/100µm) No radiation effect on slew-rate dV/dt! Prefer thinner sensors because of leakage current Simulations by Charilou Labitan

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 WF2 Simulation: Radiation Effects on Signal Voltage Pad size dimension 1x1, 3x3, 5x5 mm2 Sensor thickness 100µm, 300µm Radiation effects on signal voltage are small up to 1e16 Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Need small detector sizes, small input impedance R for RC < 100ps to get large dV/dt Simulations by Charilou Labitan

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 WF2: Radiation Effects on Pulse Height and dV/dt Pad size dimension 1,3,5 mm are indicated for 2 sensor thickness’ 100µm, 300µm Max pulse voltage depends on capacitance Small dependence on radiation level Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Slew-rate dV/dt depends on the pad capacitance. Small dependence on radiation level Need small detector sizes, small input impedance R for RC < 100ps to get large dV/dt. Simulations by Charilou Labitan

Sensor Thickness Dependence of MIP: WF2 vs. Data Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 N. Akchurin etal. A. Bornheim et al E. Currás etal shown by Marcello, Arabella Simulations by Nicolo Cartiglia BB gain ~150, noise = 2 mV Very good agreement of the WF2 simulation and the MIP MPV data. The apparent increase of the MIP MPV with sensor thickness is caused by the sensor capacitance, not by an increase in the sensor current! Careful investigation of the impact of various sensor-BB amp options with different RC values should be considered. (N.B. how was the S/N in the data calculated when the noise was quoted as 2mV?)

Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016 Conclusions The P-i-N diodes present a unique opportunity for fast timing given their pulse shape The fast rising edge of the current pulse from SiPads of all thicknesses and areas are identical with sufficient over-depletion of the sensors. The rising edge of the voltage pulse is shaped through the RC of the SiPad capacitance and the input impedance of the broad-band amplifier. Since the time jitter depends inversely on the slew-rate, lower sensor capacitances are preferred since they result in higher slew-rate. Concurrent pulses from N MIPs have N-times the slew rate and thus 1/N the time jitter The data on time resolution of multiple MIP events in SiPad presented today are reproduced by the simulations using the Weightfield2 (WF2) program. Given that the capacitance of the pads depends both on area and thickness of the SiPad, it opens the opportunity to optimize the geometry of the sensors depending on Physics and detector performance; e.g. 5mmx5mm, 300µm thick sensors have ≈ the same capacitance as 3mmx3mm, 100µm and thus the same slew-rate dV/dt and timing resolution. To match the jet size one might go with the 5mmx5mm pad, or for radiation mitigation one might opt for the thinner bulk of 100µm pads with better radiation tolerance and tighter jet confinement. Thinner sensor will have less leakage current and less leakage current induced noise, although with cooling and the short shaping times this might not be an unsolvable issue. We should look forward to see how our electronic colleagues will face the challenges to minimize noise and power as well as optimize the time measuring systems. Hartmut F.-W. Sadrozinski, Energy & time with HGSD, 6/13/2016