Clic Vertex Thermal set up 22/07/2013 François-Xavier NUIRY Maxence CURDY CERN PH/DT/EO
Overview General design Stave height tuning Setting of the box Fan DAQ Flow-meter
General Design 1770mm Flow Formed by: - a fixed set Fan + Set with the Stave - a moving box
Stave height tuning
Setting of the box a) Maximum displacement of the box
Setting of the box the three combinations can be tested
First layer
Second layer
Third layer services are not considered
Setting We can also adjust the stave to the flux in 3 positions thanks to the pin holes: - 90° - 45° - 0°
Gaskets Gaskets for the set Gaskets for the box
Stave Fixation Front view Section view
Production status Infrastructure: -Bosh profiles: Waiting for the quote. -Plexiglas / polycarbonate walls: Waiting for the quote. -Joints: Waiting for the quote. -Junction rectangle / cylinder: Should be done for end of August -Small mechanical parts: should be done in August.
Fan Ebmpapst : 6318/2TDH4P Category: Axial compact fans Air Flow: 950m³/h Dimensions: 172Ø x 51 mm Power: 150w Weight: ~0.9 kg Flow regulation can be possible. Delivery around mid august.
Calcul Fan characteristics @ 48V DC Network characteristics M3/h
Flux Developing profile length calculation Solodkin and Ginebski L/Dh=3.28*log(Re)-4.95
Flux Developing profile length VS box height Solodkin and Ginebski L/Dh=3.28*log(Re)-4.95
DAQ Total~ 4500chf NI cDAQ-9188, Ethernet connection, 1850CHF OK for PT100 OK for Anemometers OK for Capacitive sensors (vibrations) Analogue input modules: -9217 for PT100 sensors 16 bit (4 sensors per card) ~625CHF * 3 -9208 for anemometers and capacitive sensors. 16 bit. ~715CHF Connector Sub D 37 Total~ 4500chf
Flow-meter Waiting for the quote It seems to be ok in terms of integration, wind speed range, DAQ compatibility, precision (+/-3% with the optional high precision). It’s quite expensive, the price should be around ~700 euro per sensor. Small problem: the orientation of the sensor has to be precise (+/-3°).