BY KAUSTUBH V GITAPATHI DIRECTOR VI AUTOMATION (P) LTD, PUNE

Slides:



Advertisements
Similar presentations
Stator Voltage Control
Advertisements

The stator winding are supplied with balanced three-phase AC voltage, which produce induced voltage in the rotor windings. It is possible to arrange the.
Introduction to Electrical Machines
Induction Motor •Why induction motor (IM)?
Chapter 6 DC and AC Machines
Power System Fundamentals
EE20A - Electromechanical Energy Conversion Induction Machine
Physics 12 Direct Current Motors. Joke of the day: An object at rest stays at rest and an object in motion stays in motion with the same speed and in.
Electro Mechanical System
Who Wants To Be A Millionaire? Electricity and Magnetism.
Electrical Theory I - The Basics
Lesson 37 AC Generators II
Lesson 33 AC Generators.
ET 332a Dc Motors, Generators and Energy Conversion Devices 1Lesson a.pptx.
AC MOTOR INDUCTION MOTOR.
Three-Phase AC machines
Introduction to Electrical Machines
ET 332a Dc Motors, Generators and Energy Conversion Devices 1Lesson a.pptx.
PUMP TESTING BY KAUSTUBH V GITAPATHI DIRECTOR VI AUTOMATION (P) LTD, PUNE.
Motor Testing (Motor Only)
Power System Fundamentals EE 317 Lecture 7 20 October 2010.
Introduction to AC Motors ChE 462. AC Motors Synchronous motor – constant speed independent of load; compressors Induction motor is a common form of asynchronous.
1 Motors and Generators ©Dr. B. C. Paul More Fun with Flux Mechanically Rotated Shaft Slip Rings Wires with brush contacts to slip rings Electromagnetic.
Performance Characteristics
1 ELECTRICAL TECHNOLOGY EET 103/4 Define and explain the meaning of current, voltage, resistance, power, conductor, and insulator.
EET 306 ELECTRIC MACHINES Syafruddin Hasan.
AC Machine CHAPTER 3 EKT 415. AC Machine  Alternating current (ac) is the primary source of electrical energy.  It is less expensive to produce and.
Motors and Generators.
Induction Motors Equations, Performance, Electrical Equivalent Circuits.
Magnetic field due to an electric current
Problem # 5-7 A 3-phase, 8-pole, induction motor, rated at 874rpm, 30hp, 60Hz, 460V, operating at reduced load, has a shaft speed of 880 rpm. The combined.
Direct mechanical load testing Herman vd Merwe (Engineering Manager) Revision: November 2005.
EFFECTS OF VOLTAGE IMBALANCE ON 3-PHASE INDUCTION MOTORS DESIGN TEAM 3.
UNIT 17: TYPES OF ELECTRIC MOTORS
SMJE 2103 Induction Motor.
Induction motor National Research Tomsk Polytechnic University Student: R.N.Kalimbekov Group 5GM42 Teacher: O.S.Kachin Tomsk 2015.
Proportional and Servo Valves
Prepared by:- Chandan pathak ( ) Utpal rathod( ) Hitendra vyas( )
SMJE 2103 Induction Motor.
Lesson 12a: Three Phase Induction Motors
Hafizism february 2007 EMT462 Electrical System Technology LECTURE V mohd hafiz ismail level II jejawi.
Some Theory Voltage Resistance Current Ohm’s Law
Equations, Performance, Electrical Equivalent Circuits
Unit – IV Starting and Speed control of Three phase Induction motor
Lesson 14: NEMA Designs and Induction Motor Nameplate Data
Speed control of three phase induction motor
Under load-simple calculations
Lesson 34: AC Generators II
高等電機機械 報告者:朱振源 指導老師:秦純 教授.
Electric Machine Induction Motor
Chapter 6: DC & AC Machine
AC MACHINE Hasnizah Aris.
Induction motor control
Three Phase Induction Motors
Disc Thickness Measurement System
A Presentation of Testing Of D.C Machine
TORQUE MEASURMENT.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. Chapter 17 AC Machines.
Energy Conversion and Transport George G. Karady & Keith Holbert
Three Phase Induction Motors
Determination of Induction-Motor Parameters
Utilisation of Electrical Energy
MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric.
Utilisation of Electrical Energy
Utilisation of Electrical Energy
SINGLE PHASE INDUCTION MOTOR.
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Equations, Performance, Electrical Equivalent Circuits
Electrical Machines (EELE 3351)
Electric Machine Design Course
Presentation transcript:

BY KAUSTUBH V GITAPATHI DIRECTOR VI AUTOMATION (P) LTD, PUNE PUMP TESTING BY KAUSTUBH V GITAPATHI DIRECTOR VI AUTOMATION (P) LTD, PUNE

Pump Test - Requirement No Load Test High Voltage Test Insulation resistance – Measured with 500V DC On Load Test Lock Rotor Test CALCULATED PERFORMANCE AT ACTUAL FREQUENCY Flow Head Pressure Efficiency

Pump Test - Parameters Measured 3 Phase. 5HP to 300 HP 1 Phase Pump Test - Parameters Measured 3 Phase 0.5HP to 300 HP 1 Phase 0.5HP to 003 HP Voltage Current Resistance Frequency RPM Pressure Flow Leakage Current (HV Test – 1.5KV) Insulation Resistance Starting torque Temperature

Pump Test - Parameters Controlled Solenoid valve for Lock Test (24 V)

Pump Test – No Load Test No load tests could be done at the various voltages starting from 150V to 450V. The system would be programmed to carry out the tests at the following voltages. For three phase: 150V 200V 250V 300V 350V 400V 415V 450V 1000 v For single phase 140V 160 V 180 V 200V 220V 230 V

Pump Test – No Load Test The following parameters would be recorded and tabulated Voltage Current Power Frequency CW RPM CCW RPM Slip Resistance

Pump Test – High Voltage Test High voltage test would be carried out by connecting 1500V AC across the coils and motor body. The leakage current in mA would be recorded. An indicator light will glow to indicate if the leakage current is at acceptable levels. If the current exceeds the limit another light will glow indicating failure.

Pump Test – Insulation resistance – Measured with 500V DC The insulation resistance in mega ohms would be determined by applying 500V DC across the coils and the motor body. The resistance in mega ohms will be recorded An indicator light will glow to indicate if the resistance is at acceptable levels. If the resistance is less than the limit another light will glow indicating failure.

Pump Test – Locked Rotor test The following parameters will be recorded in locked rotor condition. The rotor would be physically locked during this test. Voltage Current Power

Pump Test – On Load test Load test will be done by varying the flow rate with the help of motorized valve. Tabulated readings as well as graphical display of various parameters Vs flow rate will be provided. The following parameters would be measured and displayed graphically as and when required to be viewed Current Vs Flow rate Power Vs Flow rate Efficiency Vs Flow rate Pressure Vs Flow rate

Pump Test – Parameters Display Resistance: RB, YB, RY Pump Type Flow Head Supply Frequency Overall Efficiency NP in KW NM in KW Sp. Gr. Of liquid used for testing. Motor Type Motor Rated Power in KW Frequency, Voltage and Current.

Pump Test – No Load Parameters Display Voltage Current (Run, Start and Line) CU Loss (Calculated) Power Power CU Loss at No Load (Calculated)

Pump Test – On Load Parameters Display at Actual Frequency Current (Run, Start and Line) Power STATOR Input STATUS CU Loss (Calculated) Losses (Mechanical, Iron, CU Loss) (Calculated) Frequency RPM Direct Input from (CW, CCW)

Pump Test – Sample Report

Pump Test – Additional Features Interface with company Database Reporting in Company Format Data Sharing on Internet Any customized requirement

Pump Test – System Components Data Acquisition System Energy Meter Slip- Speed Meter Magnetic Flow Meter Temperature Indicator Head Meter Solenoid Valve

Pump Test – Additional Information Contact Mr. Kaustubh V Gitapathi (Mb: 9850823210) Director VI automation P Limited C/2, Apna Ghar Housing society, Shankarsheth Road, Pune 411041 E mail:- kaustubh@viapl.com Web: - www.viapl.com Ph: +91 20 64002256/7 Fax: +91 20 26451554