TE-MPE-CP, RD, 03-Dec Quench Detection and Energy Extraction Systems R. Denz (Quench Detection), K. Dahlerup-Petersen (Energy Extraction Systems),
Advertisements

TE-MPE –TM, 16/05/2013, Mateusz Bednarek, TE/MPE-EE ELQA testing during and beyond LS1.
REVIEW OF THE CRYOGENIC BY-PASS FOR THE LHC DS COLLIMATORS ELECTRICAL CIRCUIT MODIFICATION, INCLUDING OPERATIONAL CONSIDERATIONS PRESENTED BY A. SIEMKO.
1 Copper Stabilizer Continuity Measurement Project CSCM Mini Review Powering Implementation H. Thiesen 30 November 2011.
How to achieve higher redundancy of the UPS for QPS ? -The lack of redundancy concerns the supply lines from UPS to consumer but equally parts of the UPS.
A. Siemko and N. Catalan Lasheras Insulation vacuum and beam vacuum overpressure release – V. Parma Bus bar joints stability and protection – A. Verweij.
TE-MPE-EP, RD, 06-Dec QPS Data Transmission after LS1 R. Denz, TE-MPE-EP TIMBER PM WinCC OA Tsunami warning:
Chamonix Risks due to UPS malfunctioning Impact on the Superconducting Circuit Protection System Hugues Thiesen Acknowledgments:K. Dahlerup-Petersen,
1 Second LHC Splice Review Copper Stabilizer Continuity Measurement possible QC tool for consolidated splices H. Thiesen 28 November 2011 K. Brodzinski,
CERN Rüdiger Schmidt FCC week 2015 Long Magnet Stringpage 1 Incident September 19 th Architecture of powering and protection systems for high field.
Becoming familiar with QPS systems in the LHC (incl. EE) Presentation 02 Sept PART 1 of 3. Part 1: General layouts and principles Presentation of.
Update and status for the Work Unit ‘Energy Extraction’ - equipping the three test benches for series testing of Super-FRS Dipoles D2, D3, D4 and Quadrupoles.
Training LHC Powering R. Denz Quench Protection System R. Denz AT-MEL.
AT-MEL-PM, R. Denz, CERN, CH-1211 Geneva 23 1 QPS system and its risks  Principal risks  General remarks  Quench heater circuits  Quench detection.
For more info:
AT-MEI-PE, RD, LIUWG 31-JUL R. Denz AT-MEI-PE LHC Luminosity Upgrade Protection of the Inner Triplet, D1, Correctors and Superconducting Links/Leads.
13 kA Energy Extraction LHC machine Gert Jan Coelingh – Knud Dahlerup-Petersen – TE/MPE/EE.
Essential lessons from commissioning of the 28 EE systems of LHC sector A corrector circuits.
Power Converters and DC cablesSlide 1/.. LHC - HC review Hugues THIESEN – AB/PO Thursday, 12 May 2005 Water cooled cables warm bus bars power converter.
BCWG - 16/11/20102 Content WHY do we need a HW Commissioning campaign? WHAT are we going to do? HOW are we going to do it? ElQA QPS Powering Tests Planning.
Andrzej SIEMKO CERN, Geneva The 2014 Kyoto Workshop on HTS Magnet Technology for High Energy Physics –WAMHTS-2.
TE-MPE-CP, RD, LHC Performance Workshop - Chamonix Feb R. Denz TE-MPE-CP on behalf of the QPS team QPS Upgrade and Re-commissioning.
Quench Detection System R. Denz TE-MPE-EP on behalf of the QPS team.
TE-MPE -EI 23/6/2011,Antonopoulou Evangelia RQS circuit Simulation results of Quench Antonopoulou Evangelia June 2011 Thanks to E. Ravaioli.
Advanced simulations of events in the RB circuit Short circuit to ground Quench of a dipole provoked by the quench heaters Emmanuele Ravaioli Thanks to.
HWC with nQPS Splice Monitoring Zinur Charifoulline & Bob Flora Real Time (~10 sec) BUS Voltage Energy Extraction Trip 300 µV threshold on Un-bypassed.
Machine Protection Review, R. Denz, 11-APR Introduction to Magnet Powering and Protection R. Denz, AT-MEL-PM.
Main dipole circuit simulations Behavior and performance analysis PSpice models Simulation results Comparison with QPS data Ongoing activities Emmanuele.
LHC circuit modeling Goal: Create a library of electrical models and results for each circuit Useful and usable for the next 20 years…… Web site cern.ch/LHC-CM.
Training LHC Powering - Markus Zerlauth Powering Interlocks Markus Zerlauth AB/CO/MI.
CERN TE-MPE-EP, RD, 09-April Quench Protection Systems (QPS) for the LHC R. Denz, TE-MPE-EP Acknowledgements: K. Dahlerup-Petersen, A. Siemko, J.
TE-MPE-CP, RD, 28-Sep Problems with QPS DAQ Systems During LHC Operation, 1 st Results from 2010 CNRAD Tests R. Denz TE-MPE-CP.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Machine Protection Review, Markus Zerlauth, 12 th April Magnet powering system and beam dump requests Markus Zerlauth, AB-CO-IN.
Inner Triplet Protection Strategy LHC & HL-LHC Daniel Wollmann with Inputs from B. Auchmann, G. Ambrosio, R. Denz, P. Fessia, E. Ravaioli, F. Rodrigues.
Hardware Commissioning Review, R. Denz, 12-May Superconducting circuits: what remains to be done during hardware commissioning R. Denz AT-MEL-PM.
Main MPE Activities during YETS/EYETS/LS2 and the Provision of Resources Andrzej Siemko Andrzej Siemko TE-MPE1.
Mikhail Ovsienko TE-MPE-EE
Electrical Configuration and System Protection
Protection and Relay Schemes
DQLPUR Project Overview and Plans Review 30 November 2012
D1 and D2 powering and protection
11T Magnet Test Plan Guram Chlachidze
Powering LHC magnets version 30/3/2007.
The HL-LHC Circuits: Global View and Open Questions
Status of RB circuit modeling PSpice models Simulation results: nQPS & oQPS Comparison with QPS data Ongoing activities Emmanuele Ravaioli TE-MPE-TM
Superconducting Circuits, a generic view
RELIABILITY OF 600 A ENERGY EXTRACTION SYSTEMS
Ideas and design concepts, and challenges
12 October 2009 RRB Plenary R.-D. Heuer
Powering the LHC Magnets
FMEA of a CLIQ-based protection of D1
MPE main activities planned for LS2
the CERN Electrical network protection system
Update on circuit protection simulations of the HL-LHC Inner Triplet circuit Matthias Mentink, Circuit specifics + STEAM simulations: Samer Yammine, LEDET.
Focus Coil Quench Detector
Dipole circuit & diode functioning
Powering from short circuit tests up to nominal
Circuits description and requirements - Closed Session-
Re-Commissioning (IST) of Electrical Systems: QPS, EE & PIC
LHC BLM system: system overview
Detailed global view on protection and detection of the circuits
Quench detection electronics for the HL-LHC magnet circuits of the LHC
Rüdiger Schmidt and Karl Hubert Mess
Machine Protection Xu Hongliang.
COOLING OF POWER DEVICES
Agenda Introduction of Protective Relays
Other arguments to train two sectors to 7 TeV
R. Denz, TE-MPE-EP Acknowledgements: J. Steckert
J. Fleiter, S. C. Hopkins, A. Ballarino
Presentation transcript:

Knud Dahlerup-Petersen Presentation at PH/ESE Electronics Seminar of the Superconducting Circuit Protection Systems in the LHC on 15 November 2011 Knud Dahlerup-Petersen Jens Steckert In two parts (short summaries): PART 1: Overall system description - functionality - performance Knud PART 2: Detector electronics in details, with focus on recent developments and including radtol upgrade Jens Scope of Part 1: - General definition of protection strategies, methods and equipment - iQPS / nQPS - Detector principles and topologies - Heater energy storage and discharge circuits - The Energy Extraction facilities - Controls, supervision, interlock loops and operational aspects

Some definitions and considerations: A Quench Protection system does not protect against the appearance of quenches. Quenches are natural phenomena and may occur in every superconducting component. A QPS system protects the circuit during and after the appearance of the quench so to prevent serious damage to the superconductor, independent of the origin of the quench (conductor movements, sources of external heating such as beam losses or insufficient refrigeration etc.) The LHC QPS systems are made for protection of healthy electrical circuits. In case of certain defects, such as a discontinuity of the copper stabilizer across a superconducting joint, the QPS system may not be able to save the circuit – even after correct application of the protection features of the circuit, as the current decay time may be too long. The same is true for a sudden rupture of a s.c. busbar connection if the busbar signals show provide no pre-warning. -In particular, long chains of series-connected magnetic elements are exposed to risk of heavy damage in case of an inadequate or faulty QPS system. -It is the huge quantity of stored energy which provides the potential of damage. 10 GJ in the eight main dipole circuits ! -The QPS systems in the LHC consists of 350 tons of components, ranging from control and supervision electronics to heavy electrical machines. The electronic parts of detection, heater firing and energy extraction represents 175 tons of boards and crates. -The QPS systems are constantly undergoing consolidation and upgrades (due to obsolete components, new discoveries and challenges, SEU mitigation and need for increased redundancy .

The four cornerstones of a protection scheme for a superconducting powering circuit in the LHC are: Quench Detection by resistive voltage recognition followed by immediate activation of further protection measures Coil Heating by Strip Heater Powering through discharge of Power Sources with stored energy By-passing the Quenching Magnet through conduction of a Cold, Parallel Diode Extraction of the Stored Energy (EE) to resistor elements in the warm part of the circuit Note: Not all LHC s.c. circuits need all four protection features. Generally, individually powered magnets have only detectors and heaters, a 600 A corrector magnet chain has only detectors and EE (external or internal). However, the 24 LHC Main Circuits require all four features. AFTER DETECTION OF A QUENCH THE S.C. CIRCUIT MUST SUPPORT THE DECAYING CURRENT DURING THE DISCHARGE TIME (e.g. 4-5 τ) !!!

Main dipoles and quadrupoles: Detection Strategies for the LHC Machine for the various types of s.c. elements: Main dipoles and quadrupoles: Analog quench detectors, quench heaters, cold by-pass diodes and energy extraction systems (two per dipole citrcuit, one per quad circuit) Main bus-bars: Digital quench detectors, distributed around the ring, with local data acquisition systems Insertion region magnets, inner triplets and associated bus-bars: Global protection of magnet and bus-bar by digital quench detector combined with quench heaters Correctors magnet circuits: Global protection of magnet and bus-bar by digital quench detector (not comparator) Often parallel resistors across the coils. External Energy extraction systems where necessary HTS current leads: Individual detection by digital detector system reacting on the circuit protection system Supervision of all protection equipment: Data acquisition systems based on Fieldbus net including Gateway computers at surface

General features for all QPS systems: 1. Powering by two (at least partially) redundant UPS power grids (see slide in nQPS presentation) with an autonomy of at least 10 min. (Only exception is the closing procedure for the 13 kA EE breakers) 2. Redundant detector topology systematically implemented everywhere Board A / Board B. Both boards permanently active. For reasons of cost savings only data transmission from one board (selective). 3. All instrumentation wires from the cold masses are doubled and used individually in the detection system 4. As the detector electronics has the same potential to ground as the device to protect, galvanic isolation is provided on the boards by b - for signal transmission: digital isolators (e.g. ISO150) and isolation transformers - for interlocks: opto-devices or relays -use of internal ac/dc power sources 5. Various test modes implemented on the detector boards. E.g. ramping of internal voltage for simulation of a quench. 6. If any adjustments (e.g. zero-offset reset) required, these can be applied from remote.

Circuit Detection system(s) Quench heater power supplies Energy extraction systems Main circuits RB 4 per magnet, 6 16 per circuit 2 x 13 kA RQD, RQF Analog bridge (Wheatstone) for each magnet, differential numerical detection , energy extraction system(s). systems for busbar ,s, protection system for HTS leads, cold bypass . 2 per magnet, 94/102 per circuit 1 x 13 kA Insertion region magnets RQ7 to RQ10 2 per magnet, up to 4 per circuit No RQ4 to RQ6 2 or 4 per magnet , up to 8 per circuit RD1 to RD4 Numerical bridge including busbar (comparators), protection system for HTS Heaters. leads 2 per magnet RQ6 around point 3 and 7 RU (undulators) in point 4 D ifferential numerical detection system including busbar, protection system for HTS leads , internal parallel resistors 1 x 600 A Inner tripl ets RQX Numerical bridge including busbar, protection system for HTS 2 per magnet, 8 per circuit Inner triple t correctors RCBXH, RCBXV, RQSX including busbar , protection Corrector magnet circuits RCD, RCS, ROD, ROF, RQS, RQTD, RQTF, RSD, RSF, RSS RCO RQT, RQTL, RQS system for HTS leads, internal parallel resistors (all but RCD, ROD, ROF, RCO) No comparators – calculation with use of inductance tables.

System Detection threshold [V] Evaluation time Core technology Main magnets MB & MQ ± 100 mV (200 mV symQ) 10 ms Analog comp+ hardw logic / dig.processor Main busbars by nQPS 300 μV (500 μV) 10 s Microprocessor Insertion region magnets 0.1 / 5.0 absolute 10 ms Digital signal pr ocessor Inner triplets 7.5 absolute processor Corrector magnet circuits 2 (I < 50 A) 20 ms HTS leads 0.003 HTS part / 0.100 resistive part 100 ms Sigma delta ADC + microprocessor Note: Complete QPS reaction time = circuit reaction time to attain threshold + filtering and discrimination (evaluation) time + interlock reaction time.

1. Examples of detector principles in the LHC: The 1624 Main Magnet Detectors. FOR ASYMMETRIC QUENCHES: - Analogue electronics for comparison (by Wheatstone bridge principle) of two coil voltage -for dipoles: the total aperture voltage beam 1 against the total aperture voltage of beam 2 -for quadupoles: One half-coil voltage of one aperture against the other half-coil voltage of the other aperture (one aperture of a SSS (quadrupole) belongs to QF circuit, the other aperture to QD circuit) - Following a detection a Fast Power Abort Interlock (FPA) is being activated, reacting on PIC (powering Interlock Controller), quench heater firing and Energy Extraction. - Detector crate mounted in the LOCAL PROTECTION UNITS (DQLPU’s – 1624 racks). Hardwired logic and EN61000, 4 kV EMC proven. - Radiation tolerant electronic - tested in TCC2. -2 redundant detector boards FOR SYMMETRIC QUENCHES: The new DS Symmetric Quench Protection Layer - see nQPS part.

3. Examples of detector principles in the LHC: Inner Triplet Quads. 2. Examples of detector principles in the LHC: Insertion Region magnets - Stand-alone Quads and Separation Dipoles - Global Protection Units, i.e. magnet coils and associated s.c. busbars are protected by same detector, as one circuit. Detection by Numerical Bridge . Separate detector for the two (dipoles) or three (quads) HTS Current Leads. For each detection always two redundant boards (DQQDI). 2 to 8 heater powering circuits with identical number of DQHDS discharge heater power supplies (identical). Thresholds: 100 mV with discrimination time of 20 ms and overall circuit voltage threshold at 5 V. Some problems with noise pick-up of Q10, Q9 and Q8 (very long instrumentation lines). 3. Examples of detector principles in the LHC: Inner Triplet Quads. Same detector equipment as for insertion magnets However quantities are different: 2 x 4 DQHS quench heater power supplies 3 Global-system detectors (DQQDT) 4 Current Lead detectors (DQQDC) All 8 heaters fired simultaneously.

4. Examples of detector principles in the LHC: 600 A Corrector Circuit Protection. Concerns in total 836 circuits with currents from 100 A to 600 A. Comparators cannot be used due to lack of internal instrumentation wires (not mounted). The detector consists of one system for the magnet chain and interconnecting busbars and two systems for the HTS current leads. The digital quench detector board is a calculator (DQQDG). From measurements of circuit voltage (Udiff) and circuit current (Icircuit, by LEM transducer) dIcircuit is created through a numerical/analog feedback loop. With digital filter system. URES is calculated using pre-loaded inductance tables obtained from measurements of the installed magnet chains. Thresholds: 100 mV, 2o ms discrimination time -for I > 50A 2 V for I < 50 A. -Problems are occasionally encountered at zero-passage of power converter voltage and during tune adjustments (RQTF/RQTD). 202 circuits are equipped with external Energy Extraction systems.

5. Examples of detector principles in the LHC: Current Leads protection.. First high-precision digital detector board developed by QPS Featuring - Resolution in the order of a few µV can be reached - Based on a 24 bit ΣΔ ADC and µ-processor - For current leads thresholds of 3 mV for HTS part and 100 mV for resistive part, 100 ms is presently implemented - Always two redundant channels (one the same board) for one single lead - 1200 such boards installed and operating - Design later used for the DQQBS busbar splice detector board (nQPS part of presentation).

The ‘Quench Loop’ and other Interlock loops. Example 1: The Main Dipole Circuit. 2 x 3 km long loop across an arc. Similar loop for RQF and RQD. Example 2: Interlock loop for a Stand Alone Magnet, connecting the QPS system with the power converter (PC) and the powering interlock controller (PIC) NOTE: The Power Permit signal is transmitted through a software link.

QPS Supervision Architecture. -The QPS controllers are named DQAMC (main magnets), DQAMS (energy extraction), DQAMG- type A (corrector circuits), DQAMG-type B (insertion magnets), DQAMG-type C (inner triplets) and DQAMG-S (nQPS crates, for BS and DS systems). 24 Gateways (front-end computers with Ethernet link) 55 fieldbus segments (40 in tunnel, 15 in galleries)

Quench Heater Discharge System (DQHDS power sources): In total 6’076 DQHDS units installed in the LHC + spares. 2.9 kJ of stored (capacitive) energy per DQHDS unit. Charged to 920 V (+/- 460 V with respect to ground). Assures active protection by spreading the quench area to the whole coil with a few hundred ms typically. Activated through triggering of two power thyristors. Integrated into the quench protection racks under the main magnets or installed in instrumentation racks in the galleries and tunnel enlargements. 4 DQHDS units per dipole magnet, 2 per quadrupole magnet (SSS). 2-4 units for an insertion region magnet.

Energy Extraction in the LHC Powering Circuits Purpose: -For the Main Dipole and Quadrupole circuits: Rapid current decay (still within the limits of quench-back) with external energy deposit is required to prevent destruction by overheating of the by-pass diodes and associated copper busbars and the quenching s.c. busses -For the corrector circuits: In the absence of heaters EE is vital for energy absorption and for obtaining the short discharge time which will prevent overheating of busbars, current leads and coils. Note: De-excitation by inversion (-10 A/s), with reversed energy flow to EdF grid, is applied in the RB circuit (thyristor converter) whenever possible (no circuit faults, no quenches, when Mains grid is available).

Rapid creation of an exponential current decay is achieved by switching into the magnet powering circuit one or more extraction resistors, designed for safe absorption and rapid dissipation of the highest quantity of stored energy in the chain. The EE systems participate in the global protection of leads, busbars, magnet coils. Main Dipole powering circuit with two series-inserted EE systems Main Quadrupole powering circuit with one series-inserted EE system 600A powering circuit with external EE system, crowbar and internal, parallel resistor.

Components of an EE system: Extraction switches - powering and control electronics - a current distribution system - the extraction resistors - their supervision electronics - their cooling facility - an Interlock and alarm system - the system Interface and Data Acquisition electronics - various auxiliary systems (e.g. arc detectors, over-current detectors, snubber capacitor banks and their electrical protection equipment, sound shields). Basic Requirements: Reliability of the release systems - availability - low losses and radiation tolerance. When paralleling of switches are used each individual switch shall be capable of interrupting the full-system current ! Some Key Figures: The 232 EE facilities in the LHC represent 310 tons of equipment. Basically all components are tailor-made to the application, off-the-shelf equipment did not meet the CERN specification. 89% of the equipment is procured as in-kind contributions from Non-Member States The total reference cost of the systems was 19 MCHF. CERN paid 7 MCHF plus installation cost. Stored Energy: In each circuit: RB: 1’236 MJ at ultimate current (sufficient to heat and melt 2.2 tons of copper) RQF/RQD: 24 MJ at ultimate current. 600 A corrector circuits: up to 108 kJ Locations: Even points: all eight UA galleries (RB, QF/QD, correctors) Odd points: all six RR tunnel extensions (RB, correctors), tunnel (RB power systems in R34, R37), UJ33 (RB controls, correctors).

Extraction switch assemblies for the main circuits VAB49 Dipole DQR’s Extraction resistors for the main circuits Quad DQR’s Distribution bus Breaker controls modules and sound shield

Double-storey enclosure containing DQSQF / DQSQD Two 600A EE systems in one rack BCM: Breaker powering & controls electronics Three Dipole DQR’s under test at IHEP, Protvino, RU Two 600A EE systems under test at BINP, Novosibirsk, RU Extraction switch in point3 ‘long’ version of busway

Quadrupole resistor Dipole resistor

QPS Upgrade following events in 2008. Two events in 2008 lead to the need for an additional layer of protection electronics: The discovery of aperture-symmetric quenches (discovery made early June during the magnet training campaign. The 19 September event (sudden rupture of a s.c. main busbar ) The objectives: Provide a system capable of detecting and localize splice defects which represent a risk to the Main Magnet Chains and to the Stand-Alone Magnets, i.e. splice resistance of 50 – 100 nΩ (100µV @ 1kA). -The new system should be able to interlock the circuit with threshold 300 µV, 10 s discrimination time. -The new system should provide data for enhanced diagnostics via QPS supervision in sub-nΩ range. -The new system shall use existing instrumentation wires (the diode V-taps and I-taps, routed via D20 and D21 connectors from magnet (IFS box) to nQPS crate. Provide a new layer of main magnet protection which compares total magnet voltages and initiates a fast power abort in case of an aperture-symmetric quench. A 4-dipole and 2-quadrupole comparison was selected as it minimizes the number of heaters to be fired. The new facility should also serve as a back-up of the iQPS detectors in case of loss of UPS1 (nQPS powered from both UPS1 and UPS2). 3) Provide the means of constantly monitoring the voltage to ground of the 3 main circuits along the magnet chains.

Results from Resistance measurements on the 156 Busbar Segments in Sector34. 1 hour at 760A and 1 hour at 5.89 kA. One point every 10 s, each value being average of 5 Hz sliding average. Shows two outliers.

Ongoing & Future Upgrades of the Extraction Systems: Reasons: Difficult co-existence due to EM transients created by the high-power systems (converter and energy extraction) and picked-up by iQPS and nQPS equipment during the dynamic phases of LHC powering. - EM transmitted voltage transients from PC filter de-excitation upon switch-off and from opening of the energy extraction switches affect the operation of both the iQPS and the nQPS systems – leading to fake quench detections in particular when happening during current ramping (160 V boost voltage). - SymQ symmetric quench detectors are affected by both PC and EE. - iQPS quench detection is affected in case of simultaneous PC trip during ramping and EE switch opening. Remedies: 1) SymQ adaptive (software) filtering applied -rise of threshold detection during transients. 2) Introduction of electronic switch opening delays with respect to the PC trip (340ms/580 ms) 3) Installation of large snubber capacitors across the extraction switchgear

Umag from SymQ (DQQDS) buffer signals during PC off and EE Odd-end switch opening 340 ms after PC Even-end switch opening 580 ms after PC PC off Uqso (quench voltage) with and without snubber capacitors – during PC trip and delayed EE switch opening.

Transient reduction by capacitive snubber bank across EE switches. Fuse protection of capacitor bank Example of final installation inside DQS cluster (UA67).