Conduction Cooling Loads

Slides:



Advertisements
Similar presentations
Heating and Air Conditioning I
Advertisements

HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
Five star hotel in Nablus
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Environmental Controls I/IG
Load Calculations Dr. Sam C M Hui MECH3005 – Building Services
The Three Tiered Philosophy
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Passive Heating and Cooling
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
HVAC 7ab CNST 305 Environmental Systems 1 Dr. Berryman
Environmental Controls I/IG Lecture 12 Cooling Loads Cooling Degree Hours Energy Performance Ratings Annual Fuel Consumption Lecture 12 Cooling Loads Cooling.
Conduction Cooling Loads
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Energy Conserving Alternatives HVAC 15a CNST 305 Environmental Systems 1 Dr. Berryman.
Passive Heating. Uses the energy from the sun to keep occupants comfortable without the use of mechanical systems.
Windows. Huge variety of available building components and several important roles Thermally most important they admit solar radiation Advantageous in.
Heat Loss and Gain Heat Loss and Gain
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Why we need to calculate heating load ?
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Objectives Review heating and cooling load calculation Practice the calculation of cooling load Learn about heating systems.
HVACR416 - Design Heat Loss / Heat Gain Part 2. External Loads The greatest external load is the sun. The suns heat can get into a building in one of.
1)Does ECJ have a larger heating or cooling load? A.Heating B.Cooling.
Objectives Lean about energy transport by air Calculate Cooling and Heating loads Solve 1-D conduction Design whether condition Use knowledge of heat transfer.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
0 Load Calculation Manual Output : 1. Screen Outputs (Results, Pareto Chart, Hourly Estimation) 2. Optional Outputs (*CLTD.txt, *TETD.txt) 3.
Cooling And Heating Load Calculations
Heat Migration in the Home 1 Energy Analysis and Comfort Solutions, Inc. Understanding Heat Migration in Your Home.
EXAMPLE EXERCISE CALCULATING HEAT LOSS & HEAT GAIN  Several exhibits in the class packet are necessary to understand the entries into the Heat Loss /
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
Heat Gains into a Building
Some Pointers for your assignment..  Passive solar heating is defined as using solar energy incident on windows, skylights, greenhouses, clerestories,
Building Envelope. Physical separator between interior and exterior spaces – Walls – Floors – Roofs – Fenestrations (any opening in the structure) – Doors.
Natural Ventilation Ar. Medha Deshmukh. Masters in Environmental Architecture.
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Cooling/Heating Load Computations
Development of a new Building Energy Model in TEB Bruno Bueno Supervisor: Grégoire Pigeon.
VENTILATION AND FENESTRATION
KRJ Planning and Research-- We plan learning environments as comfortable, resource-efficient knowledge incubators. Control over… Air temperature Radiant.
Chapter 8: The Cooling Load Cooling load is the rate at which energy must be removed from a space to maintain the temperature and humidity at the design.
Technical Seminar on Application and Technical Specification June 2016
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Energy Efficiency in Jamaica’s Building Code:
Heat Loss and Gain Civil Engineering and Architecture
The Heat Balance Method
HEAT GAIN CALCULATIONS
Heat gain in buildings: Other factors
Passive Solar Energy By: David Jung.
Heat gain and heat loss in buildings
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
Heat Loss and Gain.
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
ENERGY EFFICIENCY AND AIR CONDITIONING SYSTEM DESIGN &
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
Why we need to calculate heating load ?
Heat Loss and Gain Civil Engineering and Architecture
Lecture Objectives Psychrometrics Define Heating and Cooling Loads
Quiz First 10 minutes of the class.
Announcements Exam 1 Next Class (Thursday, March 14th):
PROJECT NAME: HVAC AND MECHANICAL SYSTEMS DESIGN
Lecture Objectives Learn about Cooling Load Calculation
Heat Loss and Gain Heat Loss and Gain
HEAT EXCHANGE IN BUILDINGS. TERMINOLOGIES Thermal conductivity: is the rate of heat flow through a unit area of unit thickness of the material for a unit.
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

Conduction Cooling Loads

What You Need to Know Describe the components that make up a cooling load Understand the fundamental differences between heating and cooling loads

What You Need to be Able To Do Calculate simple conduction cooling loads Evaluate systems to identify energy savings

Terms Cooling load Total Equivalent Temperature Differential (TETD) Storage effect Time Lag Thermal mass

Cooling Load “The amount of energy that must be removed from a space in order to maintain the space within the comfort zone.” I. Cooling Load A. “The amount of energy that must be removed from a space in order to maintain the space within the comfort zone.” B. Same essential definition as heating load, only in the opposite direction C. Notice we are still building on our definition of comfort.

Good News! Same ‘R’ values Same ‘U’ values Same conduction heat transfer Same convection heat transfer Same radiation heat transfer I. Good News! A. Same ‘R’ values B. Same ‘U’ values C. Same conduction heat transfer D. Same convection heat transfer E. Same radiation heat transfer II. Fundamentally, it is not any different from our study in heating loads

Cooling Load Components roof lights partition wall people infiltration glass solar equipment glass conduction exterior wall floor

Sensible and Latent Gains load latent load cooling load components conduction through roof, walls, windows, and skylights solar radiation through windows, skylights conduction through ceiling, interior partition walls, and floor people These load components contribute sensible and/or latent heat to the space. Conduction through the roof, exterior walls, windows, skylights, ceiling, interior walls, and floor, as well as the solar radiation through the windows and skylights, all contribute only sensible heat to the space. The people inside the space contribute both sensible and latent heat. Lighting contributes only sensible heat to the space, while equipment in the space may contribute only sensible heat (as is the case for a computer) or both sensible and latent heat (as is the case for a coffee maker). Infiltration generally contributes both sensible and latent heat to the space. The cooling coil has to handle the additional components of ventilation and system heat gains. Ventilation contributes both sensible and latent heat to the coil load. Other heat gains that occur in the HVAC system (from the fan, for example) generally contribute only sensible heat. lights equipment/appliances infiltration ventilation system heat gains

Major Differences from Heating Loads Peak conditions Heat storage effect Consideration of both latent and sensible gains More unique sources of heat gain I. Major Differences from Heating Loads A. Peak conditions are usually different 1. Depends on the amount of glass and the direction of glass, but usually from noon to 5:00 P.M. 2. This means that ΔT is variable! B. Heat storage effects 1. The total heat is not immediately transferred into the space. In other words, there is a time lag between when the heat is generated and when the heat actually reaches the room. Sometimes, the heat doesn’t reach the room until after the peak occurs! C. Consideration of both latent and sensible heat gains D. More unique sources of heat gains

Time of Peak Cooling Load east-facing window roof heat gain One of the more difficult aspects of estimating the maximum cooling load for a space is determining the time at which this maximum load will occur. This is because the individual components that make up the space cooling load often peak at different times of the day, or even different months of the year. For example, the heat gain through the roof will be highest in the late afternoon, when it is warm outside and the sun has been shining on it all day. Conversely, the heat gain due to the sun shining through an east-facing window will be highest in the early morning when the sun is rising in the east and shining directly into the window. Determining the time that the maximum total space cooling load occurs will be discussed later in this clinic. 12 6 12 6 12 mid a.m. noon p.m. mid

Storage Effect (thermal lag)

Thermal Mass Dilemma

Time Lag solar effect 12 6 12 6 12 time lag B A mid a.m. noon p.m. mid The walls and roof that make up a building’s envelope have the capacity to store heat energy. This property delays the heat transfer from outdoors to the space. The time required for heat to be transferred through a structure into the space is called the time lag. For example, the heat that is transferred through a sunlit wall into a space is the result of sunlight that fell on the outer surface of the wall earlier in the day. Curve A shows the magnitude of the solar effect on the exterior wall. Curve B shows the resulting heat that is transferred through the wall into the space. This delay in the heat gain to the space is the time lag. The magnitude of this time lag depends on the materials used to construct the particular wall or roof, and on their capacity to store heat. 12 6 12 6 12 mid a.m. noon p.m. mid

Conduction – Sunlit Surfaces Total Equivalent Temperature Difference (TETD) is used to account for the added heat transfer due to the sun shining on exterior walls, roofs, and windows, and the capacity of the wall and roof to store heat. The TETD is substituted for T in the equation for conduction. Q = U  A  T TETD

Conduction Gains (Walls and Roofs and doors) Q = U x A x TETD where TETD is the Total Equivalent Temperature Differential, which accounts for Temperature difference Mass Color Solar Gain I. Conduction Gains (Walls and Roofs) A. The formula for this is: Q = U x A x CLTD where CLTD is the Cooling Load Temperature Differential B. The cooling load temperature differential accounts for 1. The storage effect 2. Unstable and highly variable temperatures

Step #1 – Select Wall Type

Step #2 Select Sun time Select color of wall Select wall orientation D = dark L = light Select wall orientation

Step #3 – Read Value of TETD

Same Steps for Roofs

For Windows Btuh = (U x A x TD) + (A x SC x SHGF) A= Area TD = outdoor design – indoor design temp. SC = shading coefficient SHGF = solar heat gain factors

EQ Credit 8.1 - Daylighting ASHRAE Standard 90.1 10% lighting load credit for harvesting 10% lighting load credit for occupancy sensors

Heat Gain from People A function of activity Always contains both sensible and latent components

Equipment - Office Best obtained from manufacturers Can be reduced by using Capture Hood Usually is sensible, but may have a latent component

Equipment Loads (ASHRAE Fundamentals)

Ventilation Load Must consider both sensible and latent loads QS = 1.1 x CFM x (T2 – T1) QL = .68 x CFM x (W2 – W1) QT = QS + QL