Introduction to the Oscilloscope

Slides:



Advertisements
Similar presentations
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Advertisements

1 Cathode Ray Oscilloscope Introduction Look and play Read instructions Break into smaller parts Decide on a simple measurement Increase your level of.
Introduction 1st semester King Saud University
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
Sine waves The sinusoidal waveform (sine wave) is the fundamental alternating current (ac) and alternating voltage waveform. Electrical sine waves are.
BASICS OF LAB SCOPES. Scope Essentials Digital Storage Oscilliscope (DSO) Voltmeter that captures voltage samples & displays them on a screen Voltage.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
Time Varying Signals.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
1 Lab #9 AC Circuits Activity #1 – Simulating a Low Pass Circuit Activity #2 – Building & Testing a Low Pass Circuit Activity #3 – Comparison of 3 methods.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
USE OF THE OSCILLOSCOPE Modified from a presentation written by David Matzke by: Donald Wisniewski, Dawn Wisniewski, Huzefa Mamoola and Angela Nolte Under.
George Washington University DC Circuits Lab Professor Ahmadi ECE 002.
1 AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz.
Purpose Learn how to use basic electronic equipment:
The Function Generator and the Oscilloscope Dr. Len Trombetta 1 ECE 2100.
Oscilloscope Tutorial
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
Introduction to the Oscilloscope Professor Ahmadi ECE002 George Washington University.
Institute Of Applied Technology ATE 1012 Grade 10 Eng. Rose Hasan.
CHAPTER 9 Oscilloscopes and Graphing Multimeters
1 Cathode Ray Oscilloscope Introduction Look and play Look and play Read instructions Read instructions Break into smaller parts Break into smaller parts.
TA: Chris Reilly Group 5: Benjamin, Ramie, Zachary, Dinal.
Single Time Constant Measurement Dr. Len Trombetta 1 ECE 2100.
Laboratory Equipment 1 st semester King Saud University College of Applied studies and Community Service 1302CT By: Nour Alhariqi.
George Washington University DC Circuits Lab Professor Ahmadi ECE 002.
Oscilloscope Muhajir Ab. Rahim School of Mechatronic Engineering
Measuring Phase Difference Dr. Len Trombetta 1 ECE 2100.
Analog Discovery Arbitrary Function Generator for Windows 7 by Mr
Scopes  An oscilloscope is a visual voltmeter.  An oscilloscope converts electrical signals into a visual image representing voltage changes over a.
Introduction to the Oscilloscope
Electronics: Principles and Applications Eighth Edition (Instrumentation Labs) Charles A. Schuler Lab 2 Introduction to the Oscilloscope McGraw-Hill©2013.
Unit 5 Learning Objective(s) L5.1a To understand the need for safe working practices when carrying out practical electronics L5.1b To understand relevant.
Physics 2225: Working With Electronic Equipment Purpose  Learn how to use basic electronic equipment: Digital multi meter Oscilloscope Function generator.
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Due DateWeek Experiment in Lab ManualTitle Pre-Lab Report Validation Post- Validation Report 3/13/20123/14/20123/17/20126To be distributedMake-up Lab for.
Generator Frequency Knob Frequency display Frequency Range Output Amplitude (output Level) Knob -20 db (output attenuate) Functions.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
AC Measurements Topics covered in this presentation:
Electronic workshop Dr. Imtiaz Hussain URL :
The University of Texas at Arlington Electrical Engineering Department
Lecture 5: DMM & Oscilloscope 1. DMM can be used to measure: DC & AC voltages – current - resistance - BJT (β test) - diode test - short circuit test,
The Basics Electronics. To familiarise yourself with electronics To have an understanding of how and why we test electronic circuits. To complete a test.
BASIC INSTRUMENTS - oscilloscopes
1 Phase Angle Measurement Using the Oscilloscope This procedure measures the phase angle difference between two sinusoidal waveforms connected to channels.
Volt/Division and Time/Division 1) Auto Setup Finds signals and sets the appropriate horizontal / vertical /trigger settings.
The Function Generator and the Oscilloscope Dr. Len Trombetta and Dr. Dave Shattuck 1 ECE 2100.
Oscilloscopes. Objectives –After completing this chapter, the student should be able to: Explain the function of an oscilloscope. Identify the basic parts.
Residential Cabling Technologies Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Electrical Measurements.
Cathode Ray Oscilloscope Introduction
Cathode Ray Oscilloscope Introduction
ELECTRONIC DEVICES AND CIRCUITS
(5) DMM & Oscilloscope.
Alternating voltages and currents
Oscilloscope.
Electronics: Principles and Applications (Instrumentation Labs)
Harmonic Distortion Analyzer, Wave Analyzer and Function Generator
Cathode Ray Oscilloscope Introduction
Analog and Digital Signals
electronics fundamentals
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
Analog and Digital Signals
Analog & Digital Signals
6. USING THE TDR200 IN ANALOGUE MODE
Lab 8 Induction to Oscilloscope
724 Temperature Calibrator
Oscilloscopes Oscilloscopes can be used for Measuring DC voltages
Automotive Technology Principles, Diagnosis, and Service
2019 Investing Now Summer Program
Introduction to the Oscilloscope Engr. Annalyn soria Lecturer.
Presentation transcript:

Introduction to the Oscilloscope George Washington University

George Washington University OBJECTIVES Lab Safety Review Electrical Signals Quick Overview Explain Common Lab Equipment Oscilloscope, Function Generator, etc. Learn how to use an Oscilloscope to: Measure D.C. (Direct Current) Voltage Measure A.C. (Alternating Current) Voltage George Washington University

George Washington University Lab Safety No Food or Drinks Use Common Sense In Case of Emergency If electrical, turn off the main circuit breaker Call UDP at 4-6111 Notify the staff in Room 304 George Washington University

Example Electrical Signal 5 2.5 -2.5 -5 Y=VOLTAGE (volts) X=TIME (seconds) 5 10 15 20 Above, this sine wave represents a voltage that is changing over time So at time=2.5s, what is the voltage? And again at 10seconds?...15 seconds? We can see that as time moves forward, the voltage is changing Is this an AC or DC voltage? What does that mean? George Washington University

Why do we need an oscilloscope? The Theory… Why do we need an oscilloscope? George Washington University

What are the major components? Display Screen Displays an input signal with respect to time. Control Panel Adjusts how the input signal is displayed. George Washington University

What is the purpose of an oscilloscope The purpose of an oscilloscope is to measure a voltage that changes with time and show it in a graphical format Here is the oscilloscope in our lab -Notice the X-Y axes 2) Here is our alternating voltage signal from before 3) If we measure our signal with the scope, it would look like this! George Washington University

What do we now know about the scope? VOLTAGE TIME What must the X-Axis represent? What must the Y-Axis represent? So…what do the dials do? George Washington University

George Washington University Oscilloscope: Screen Notice that the screen has ruled divisions both horizontally and vertically. The axes can be scaled, for example… If each vertical division is worth 5 seconds, what time is represented by this point? If each horizontal line represents 1 volt, what voltage is represented by this point? George Washington University

Oscilloscope: Control Panel The section to the right of the screen contains the controls necessary to adjust how the waveform is displayed on the screen. The controls allow you to alter the sweep time, amplitude, and triggering method. (Note, these topics will be discussed later) George Washington University

Oscilloscope: Input Channels How do we get the voltage into the scope? This area is broken into two parts Left Half for Channel 1 (X) Right Half for Channel 2 (Y) In the center is a switch that determines which channel will serve as the input to the scope: 1, 2, Dual or Add. Why would we want more than 1 channel? Channel 1 Channel 2 George Washington University

Equipment: Function Generator Purpose: Produces waves of different Shapes (sinusoidal, square, etc.) Amplitude Frequency Several available in the lab, but we will use the one built into the Instek Oscilloscope. (Shown) George Washington University

George Washington University The Setup… In this section, we will power on the oscilloscope and set it up to display a signal connected to the CH1 input. George Washington University

Simple Signals We Can Measure Is this signal changing over time? What do we call this type of signal? If we made a chart at the different time intervals… 5 2.5 -2.5 -5 Y=VOLTAGE (volts) X=TIME (seconds) 5 10 15 20 George Washington University

Turning on the Oscilloscope Press the POWER button located below the bottom right corner of the Oscilloscope’s screen. Set the Channel Mode to CH1. Set the Trigger Mode to AUTO. A green line or dot should appear on the screen. If not, try adjusting the Intensity or Position dials. Set Trigger To Auto Set Mode to CH1 Press Power George Washington University

George Washington University Channel Mode Switch The oscilloscope is capable of measuring voltages from two different sources. The channel mode switch is used to alternate between these sources. For this lab, we will be using Channel 1, so set the switch to the CH1 position. George Washington University

George Washington University Cables We will use three types of connecters in this lab. BNC Banana Mini-Grabber George Washington University

Making Your First Connection Obtain a BNC cable, Mini-Grabber attachment and connection them together. Connect the free end of the BNC cable to CH1 on the oscilloscope George Washington University

George Washington University Time Per Division Dial Find the Time/Div dial on the oscilloscope. This dial controls the amount of time per centimeter division. Adjust to dial to 2 milliseconds per centimeter. George Washington University

George Washington University Horizontal Position Adjust the Position dial for Channel 1 to center the horizontal line. George Washington University

George Washington University Adjusting the Display If the display is difficult or out of focus, the Intensity and Focus dials can be used to adjust it. The INTEN dial controls the brightness of the line. The FOCUS dial controls the sharpness of the line. Take a moment to adjust each one and notice the difference. George Washington University

George Washington University At this point… The channel mode should be set to 1. The TIME/DIV should be set to 2mS per centimeter. A BNC cable should be connected to the channel 1 input. The other end should have a free Mini-Grabber connection. The Trigger Mode should be set to AUTO. The Oscilloscope should be ON. The intensity and focus should be adjusted so the line is clear to see. The channel 1 position dial should be adjusted so that the green line is centered on the screen. George Washington University

George Washington University Measuring a DC signal In this section, we will use an external DC POWER SUPPLY to create a DC signal to measure with the oscilloscope George Washington University

Measuring a Direct Current Voltage Set the VOLTS/DIV to 1 by adjusting the outer dial. Turn the inner dial all the way to the right, which will put it in the calibrated position. Switch the AC-GND-DC switch for channel 1 to DC. George Washington University

George Washington University Volts/Div Dial The volts/div dial tells you the number of volts to be represented by each centimeter vertically on the screen. Here the outer dial is set to one, so each centimeter equals one volt. George Washington University

Setting Up the DC Power Supply This DC Power supply is capable of generating voltages from -25V to 25V. For this lab, we will be using the 6V supply terminals. First, press the Power Button to turn it on. George Washington University

Setting Up the DC Power Supply Press Output On/Off once to turn on the output. Press the +6V button to tell the power supply that we want to alter the output from the 6V terminals. Once done, your screen should look the same as it does on this slide. George Washington University

Setting Up the DC Power Supply The dial on the right hand side is used to increase and decrease the output value. The arrows under the dial are used to determine which digit is affected by the dial. George Washington University

Setting Up the DC Power Supply Press this arrow to Select the desired digit Press the left arrow until the digit to the left of the decimal point is blinking. Use the dial to increase the display value to 3 volts as shown. Note: You can safely ignore the value of the right most digit for this experiment. This is the digit we want to adjust Rotate this dial to alter the output value. George Washington University

Setting Up the Power Supply Now it is time to connect the DC Power Supply to the Oscilloscope. Locate Mini-Grabber connectors on the other end of the cable that was previously attached to the Oscilloscope. Attach the connecters to the DC Power Supply as shown. Note: You may need to partially unscrew the terminal knobs before connecting the Mini-Grabbers. George Washington University

Observing the DC Output Once connected, the line on the Oscilloscope display will move up three divisions. At 1Volt/Division, this equals 3 Volts. Adjust the DC Power Supply output and the Volts/Division dial and observe the changes. George Washington University

Important Observations at This Point Volts/Division Dial It does not change the voltage. It is a sensitivity dial that allows us to measure a wide range of voltages by indicating how many volts are represented by each division. George Washington University

Finishing Up the DC Measurements Go ahead and… Turn off the DC Power Supply Disconnect the Mini-Grabbers George Washington University

George Washington University Measuring an AC signal In this section, we will use the built-in FUNCTION GENERATOR to create an AC signal to measure with the oscilloscope George Washington University

Measuring a Time Varying (A.C.) Voltage Now look at the function generator built into your Oscilloscope. This device produces a voltage that varies over time. In the upcoming slides we will exam each of the controls that allow us to shape the output. Built In Function Generator George Washington University

Function Generator Controls: Wave Shape An important part of a function generator is the shape of the wave it creates. This function generator can produce a Square Wave Triangle Wave Sine Wave Press the FUNC key to change until the light below the Sine wave is lit. (Note: The Oscilloscope must be on in order to change the this option.) George Washington University

Function Generator Controls: Frequency Range This generator allows you to change the frequency (Cycles per Second) of the output wave. There are two main settings: Range/Order of Magnitude Scaling Factor First, set the range to 1K (1 kilohertz) by pressing the RANGE button until the light below 1K is on. Then, turn the frequency dial (Scaling Factor) so it points straight up. This represents a Scaling Factor of 1. Turning the dial to the left will reduce the output frequency and to the right will increase it. 1. Set the Range to 1K 2. Turn the Frequency Dial Until it Points Straight Up. What will the output frequency be with this setup? What if the scaling was set to 1.5? George Washington University

Function Generator Controls 5 Volts Peak-to-Peak 2 Volts Peak-to-Peak 1 Volt Amplitude 2.5 Volt Amplitude Not only can we change the shape and frequency of a wave, but we can also change the amplitude. George Washington University

Function Generator Controls: Amplitude Dial Another 2 Parameter Control DC-Offset (Inner Dial) Amplitude (Outer Dial) Adjusting the outer dial Clockwise will increase the amplitude. Counterclockwise will decrease the amplitude. Turn the inner dial until it points straight up. Turn the outer until it points straight up. Amplitude DC-Offset George Washington University

George Washington University Making the Connection Locate the Function Generator’s Output. Using a B.N.C. Cable, Connect the Function Generator’s Output to the CH1 Input. George Washington University

George Washington University Making the Connection Set the Volts/Division dial to 2. The inner dial should be turned fully clockwise. Change the AC-GND-DC switch to AC. Use the Position dial to raise or lower the image until it is centered on the screen. George Washington University

George Washington University Making the Connection The Time/Division dial corresponds to the amount of time in each division along the X-direction. Set this dial to 0.5ms. If it isn’t already, turn the SWP. VAR. dial to CAL With 10 divisions per screen, what is the total time span represented? George Washington University

George Washington University Triggering Now we need to tell the scope when to display the signal. Electric signals change much faster than we can observe, so we must tell the Oscilloscope when to refresh the display. We accomplish this by setting a Triggering Level. George Washington University

George Washington University Triggering Without Triggering With Triggering George Washington University

George Washington University Triggering We want to tell the oscilliscope when it is the best time for it to “refresh” the display In our wave below, we tell the scope to “trigger” or ‘capture’ the signal when it is going upward AND hits 2.0Volts SO, ‘trigger’ condition is: When we’re Going up! AND When at 2.0 Volts on our waveform! George Washington University

Triggering: Setup If it isn’t already, set the Trigger Source to CH1. Remember, channel 1 is where our waveform is coming from! If it isn’t already, set the Trigger Source to CH1. Set the Trigger Mode to Auto. In some cases, this is enough to produce a clear output, but often we will need to adjust the Trigger Level. If the output is unstable, turn the triggering knob until it stabilizes. Think of the “Level” as being WHERE on the waveform to trigger, like in our last slide, at 2.0 Volts! And the SLOPE + or -, means: going UP or going DOWN George Washington University

George Washington University Measuring the Voltage Using the CH1 Position Dial, move the wave until the bottom line up with one of the division lines. Measure the number of divisions from the bottom to the top. At 2 Volts Per Division, This wave has an amplitude of 5V. Peak to Peak Voltage = (Volts/Division) *(# of Division) Amplitude = (1/2) * Peak to Peak Voltage George Washington University

Measuring the Frequency Position to wave so that the beginning lines up with one of the vertical division markers. Count the number of divisions until the beginning of the next wave. With 0.5ms/division, this wave has a frequency of 1kHz Period = (Time/Division) *(# of Division) Frequency = 1/Period George Washington University

George Washington University Mixing It Up Increase the Volts/Division Dial to 5. Decrease the Time/Division Dial to 0.2ms. Recalculate the Peak to Peak Voltage Amplitude Period Frequency How do these results compare to the ones you previously measured? Note: If the signal becomes unstable, you may need to readjust the triggering level. George Washington University

Changing the Frequency Generator Now, change the amplitude on the frequency generator. Note that wave’s height grows and shrinks as this dial is adjusted. Next, try changing the frequency and the shape of the wave. Remember that the Volts/Division, Time/Division and Triggering Level may need to be adjusted. George Washington University

Summary: Measuring A.C. Voltage Turn on the Oscilloscope. Use the built in function generator to set the shape, frequency and amplitude of the desired output wave. Connect the generator’s output to the channel 1 input and set the input channel to AC. Approximate the Time/Division and Volts/Division. Use the Position Dial to center the wave on the screen. George Washington University

Summary: Measuring AC Voltage Set the Triggering Source to CH1. Set the Triggering Mode to Auto. Adjust the Triggering Level until the output wave stabilizes. Adjust the Volts/Division and Time/Division dials until the desired output is produced. If needed, use the Focus and Intensity Dials to sharpen the picture displayed. George Washington University