Status of the CERN ALIBAVA System

Slides:



Advertisements
Similar presentations
Combined Measurement Results of dedicated RD50 Charge Multiplication Sensors Christopher Betancourt 2, Tom Barber 2, Gianluigi Casse 1, Paul Dervan 1,
Advertisements

Characterization of 150  m thick epitaxial silicon pad detectors from different producers after 24 GeV/c proton irradiation Herbert Hoedlmoser (1), Michael.
TCT+, eTCT and I-DLTS measurement setups at the CERN SSD Lab
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
Radiation Damage in the CMS Strips Tracker Christian Barth on behalf of the CMS Tracker Collaboration.
ALBA Synchrotron – 17 June 2010 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona First Measurements on 3D Strips Detectors.
RD50 RD50 workshop FreiburgKatharina Kaska 1 Determination of depletion voltage from CV, IV and CCE measurements on Pad Detectors Katharina Kaska, Michael.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Preliminary results with the Alibava Telescope G. Casse, S. Martì, J. Rodriguez, I. Tsurin and the Alibava collaboration 1 G. Casse,20th RD50 Workshop,
Evaluation of electron and hole detrapping in irradiated silicon sensors Markus Gabrysch 1, Mara Bruzzi 2, Michael Moll 1, Nicola Pacifico 3, Irena Dolenc.
Charge Collection Study of Heavily Irradiated Silicon Microstrip Detectors Chris Lucas (University of Bristol) Irena Dolenc Kittelmann, Michael Moll, Nicola.
Status of the ALIBAVA system Ricardo Marco-Hernández IFIC(CSIC-Universidad de Valencia) 1 Status of the ALIBAVA system 13th RD50 Workshop, November.
CBM Silicon Tracking System. Microstrip Detector Module Assembly and Test V.M. Pugatch Kiev Institute for Nuclear Research GSI (CBM experiment), Darmstadt.
1 Device Simulations & Hardware Developments for CBM STS Sudeep Chatterji CBM Group GSI Helmholtz Centre for Heavy Ion Research CBM Collaboration Meeting,
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
Report on CMS 3D sensor tests Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Joachim Erfle Summary of measurements after first irradiation of HPK samples 19 th RD50 Workshop November 2011 CERN Joachim.
1/14 Characterization of P-type Silicon Detectors Irradiated with Neutrons M.Miñano 1, J.P.Balbuena 2, C. García 1, S.González 1, C.Lacasta 1, V.Lacuesta.
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept and status of the PSD temperature control - Concept of the PSD analog part.
Status of the PSD upgrade - Problems with PSD in Be runs - Modification of cooling system - New temperature control - Upgrade of HV control system - MAPD.
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
A CCE and TCT Study on low resistivity MCz p-on-n detectors Nicola Pacifico, Michael Moll, Manuel Fahrer 16 th RD50 workshop, Barcellona, 31 May-2 June.
ALIBAVA system upgrade Ricardo Marco-Hernández IFIC(CSIC-Universidad de Valencia) 1 ALIBAVA system upgrade 16th RD50 Workshop, 31 May-2 June 2010, Barcelona.
CNM double-sided 3D strip detectors before and after neutron irradiation Celeste Fleta, Richard Bates, Chris Parkes, David Pennicard, Lars Eklund (University.
PSD upgrade: concept and plans - Why the PSD upgrade is necessary? - Concept of the PSD temperature stabilization and control - Upgrade of HV control system.
NA62: The LKr Electronics Matt Huszagh. Installation & Setup (1/5) Crate Setup 8 vertical columns of 4 crates Almost all installed.
Charge Collection, Power, and Annealing Behaviour of Planar Silicon Detectors after Reactor Neutron, Pion and Proton Doses up to 1.6×10 16 n eq cm -2 A.
Study on and 150  m thick p-type Epitaxial silicon pad detectors irradiated with protons and neutrons Eduardo del Castillo Sanchez, Manuel Fahrer,
Charge Multiplication Properties in Highly Irradiated Thin Epitaxial Silicon Diodes Jörn Lange, Julian Becker, Eckhart Fretwurst, Robert Klanner, Gunnar.
Irradiated 3D sensor testbeam results Alex Krzywda On behalf of CMS 3D collaboration Purdue University March 15, 2012.
Studies on n and p-type MCz and FZ structures of the SMART Collaboration irradiated at fluences from 1.0 E+14 to 5.6E+15 p cm -2 RD50 Trento Workshop ITC-IRST.
1 Projectile Spectator Detector: Status and Plans A.Ivashkin (INR, Moscow) PSD performance in Be run. Problems and drawbacks. Future steps.
Annealing effects in irradiated HPK strip detectors measured with SCT128 chip Igor Mandić 1, Vladimir Cindro 1, Gregor Kramberger 1, Marko Zavrtanik 1,
Zheng Li, 96th LHCC open session, 19th November 2008, CERN RD39 Status Report 2008 Zheng Li and Jaakko Härkönen Full author list available at
TCT measurements of HV-CMOS test structures irradiated with neutrons I. Mandić 1, G. Kramberger 1, V. Cindro 1, A. Gorišek 1, B. Hiti 1, M. Mikuž 1,2,
MADEIRA Valencia report V. Stankova, C. Lacasta, V. Linhart Ljubljana meeting February 2009.
Status of the ALIBAVA system and the Telescope
RD50 CCE measurements and annealing studies on proton irradiated p-type MCz diodes Herbert Hoedlmosera, Michael Molla, Michael Koehlerb, Henri Nordlundc.
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Developing Radiation Hard Silicon for the Vertex Locator
The GOOFIE detector as a Ternary Mixture Monitor
Charge sensitive amplifier
Accelerated annealing with mixed irradiated detector
ProtoDUNE SP – Slow control temperature readout setup test
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Position Sensitive TCT Measurements with 3D-stc detectors
Kröhnke, 14 November 2012 FCAL Collaboration Meeting Sergej Schuwalow
Study of radiation damage induced by 26MeV protons and reactor neutrons on heavily irradiated MCz, FZ and Epi silicon detectors N. Manna Dipartimento.
Simulated vertex precision
ALiBaVa A brief overlook of Liverpool software changes, common issues and questions. A. Affolder, A. Greenall, I. Tsurin, G. Casse, V. Chmill, M. Wormald,
Setup for measurements with SCT128 in Ljubljana: SCTA128VG chip
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
A Long Term Study of Charge Multiplication
Status of n-XYTER read-out chain at GSI
Test Beam Measurements october – november, 2016
HVCMOS Detectors – Overview
BESIII EMC electronics
Stefan Ritt Paul Scherrer Institute, Switzerland
TCAD Simulation and test setup For CMOS Pixel Sensor based on a 0
Frank Hartmann on Behalf of CERN RD50 Collaboration
Irradiated FBK 3D sensor lab tests
CCE/CV measurements with irradiated p-type MCz diodes
Setup for testing LHCb Inner Tracker Modules
Pierluigi Paolucci & Giovanni Polese
DAQ and visualization software
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

Status of the CERN ALIBAVA System 15th RD50 Workshop on Radiation hard semiconductor devices 15th RD50 Workshop on Radiation Hard Semiconductor Devices For Very High Luminosity Colliders Status of the CERN ALIBAVA System Alibava – Discussion Session 15th RD50 Workshop – Cern, 16-18 November 2009 Eduardo del Castillo Sanchez, Manuel Fahrer, Michaell Moll, Nicola Pacifico

Outline Setup that makes use of Alibava Software configuration of Alibava Modification for bias Voltage setting Daughterboard failure: baseline shift Discussion

Setup that makes use of Alibava ALIBAVA DB NITROGEN VALVE COOLING PIPES BOX EXTERNAL RC FILTER PRESSURE SENSOR ALIBAVA MB TRIGGER CABLE FLAT CABLE TEMPERATURE READOUT PRESSURE READOUT USB CABLE

Setup that makes use of Alibava 15th RD50 Workshop on Radiation hard semiconductor devices RADIACTIVE & LASER SOURCE SUPPORT 2D MOVEMENT RADIACTIVE SOURCE COOLING PLATE HORIZONTAL MOVEMENT TEMPERATURE SENSOR ETHERNET CONNECTION DETECTOR BIAS CABLE Laser wavelengths : 660 and 1055 nm Radiactive source Sr 90 Cooling down to -20°C Vacuum down to 0.06 mbar Closed box constructed in collaboration with Universite Catholique de Louvain DUT ALIBAVA DB

Software configuration of Alibava Alibava system was received at CERN ~ May First runs of the Alibava system were performed on a machine with SLC 5 installed. Stability problems were encountered i.e. communication lost between PC and Motherboard, restart required. The situation was improved by installing Ubuntu 9.04. Problems are still present: after resetting the motherboard (for daugherboard exchange) a restart of the PC is required most of the times.

Modification for bias voltage setting Alibava system Every acquisition implies setting manually DC voltage Sourcemeter controller via RS232 port

In the software as we received it …

After including sourcemeter control via RS232 port …

Daughterboard failure: baseline shift 1e15 n irradiated MCz detector. (300 V) 3e15 n irradiated MCz detector. (1000 V) No annealing: signal visible (@ ~25 ns) And, in the next slide, an interesting consideration… 3e15 n irradiated MCz detector (1000 V) 3e15 n irradiated MCz detector (1000 V) 80mins @ 60ºC. The signal goes up 1000 mins @ 60ºC. No signal? Baseline increases with irradiation fluence, bias voltage and annealing, and can completely overlap the signal

Charge collection efficiency and baseline shifts… There is clearly no visible signal, but the baseline shift “fakes” a nice Landau with a collected charge of 15ke!

Measurements on unirradiated p-type Float Zone

Discussion RC bias filter cannot withstand more than 1000 V (no tollerance at all!) Gaussian + Landau fit: is the gaussian convolution just for taking care of the noise? A few objections: The noise subtraction should take away all the noise, tails included We’re talking about a convolution, not a SUM(!!!) – Manuel pointed out that in CMS the gaussian convolution is used to account for the jitter in the signal sampling – In this case we should check whether with Alibava we need it or not Here at CERN a Daughterboard suddenly died after 3 annealing steps showing quite a weird behaviour in the baseline of the signal… any clue? If the sampling of the Alibava happens at 25 ns steps, where is generated the nice 2 ns – resoluted plot shown in the main output of the root macros? Is there a 500 MHz ADC somewhere? By using more times the pitch adapters, the bond wires will get longer, thus changing the capacitance seen by the beetle. Is there any parameter to adjust to compensate for this?