PS System for DRFS PS System for Diode-type klystrons

Slides:



Advertisements
Similar presentations
TS01 Klystron Modulator Minh Nguyen May 20, 2014 Beam Voltage Stability Improvements.
Advertisements

11/27/2007ILC Power and Cooling VM Workshop Mike Neubauer 1 RF Power and Cooling Requirements Overview from “Main Linac Power and Cooling Information”
Concept Design Review (CoDR) Shore Station DC Breaker Cable model Transient Analysis Components.
Areal RF Station A. Vardanyan RF System The AREAL RF system will consist of 3 RF stations: Each RF station has a 1 klystron, and HV modulator,
SLAC Klystron Lectures Lecture #12 June 2, 2004 Klystron Power Supplies, Modulators and Testing Saul Gold Stanford Linear Accelerator Center
ILC Marx Modulator Development Program G.E. Leyh, Stanford Linear Accelerator Center.
E951 POWER SUPPLY SAFETY REVIEW 9/06/02 IOANNIS MARNERIS Brookhaven National Labs.
Experiment # 8 EE 312 & 352 Introductory Electronics Laboratory November 1, 1999 InputFilterRegulationLoad.
Three-Phase AC machines Three-Phase Cage Rotor Induction Motor – Electronic Methods of Starting and Speed Control Resource 4.
DC Power Sources for the High Power RF Amplifiers By Rolf Wedberg Review ESS Spoke RF Source 11 – 12 December 2012.
Development of Solid State Long Pulse Klystron Modulators
Linac 6575 Modulator PFN Charging Power Supply Upgrade Minh Nguyen December 5, 2012.
FID Based Pulse Generators for Accelerator Applications Vladimir M. Efanov FID GmbH, 25 Werkstrasse, Burbach, D-57299, Germany 2006.
Digital measurement system for the LHC klystron high voltage modulator D. Valuch, A. Mikkelsen, G. Ravida, O. Brunner.
C-band Accelerator system for XFEL / SPring-8 C. Kondo, T. Inagaki, T. Shintake for XFEL project in SPring-8 6/Oct/2008 Seminar at SLAC
An Assessment on Klystron Modulator Topologies for the ESS Project Carlos A. Martins (*), Karin Rathsman(**) (*) – Laval University, Dept. Electrical and.
Accelerator Laboratory 1 CFS Review of Asian Region (S. Fukuda) June 1/2010 DRFS HLRF System KEK S. Fukuda Introduction: Basic Concept of DRFS Progress.
12. Power Distribution Systems 1) Schematic diagram of part of a house wiring system 1.
1 LCWS10 in Beijing DRFS Development (S. Fukuda) 27/03/2010 DRFS Development KEK S. Fukuda Introduction : DRFS R&D Plan Talks concerning with DRFS in LCWS10.
XFEL Pulser Specification of Pulser Dump pulser with a Belhke switch
High Power RF Systems, Control and Distribution in the HINS Alfred Moretti, Brian Chase, Chris Jensen and Peter Prieto Fermilab Accelerator Advisory Committee.
Klystron Modulator for Proton Driver
HVPS Upgrade for ALS Storage Ring RF System -Disconnect Switch Status
Brief introduction to Imtech Power Electronics “High Gradient Day”, 31 January 2013.
Power Supply System for DRFS
Accelerator Laboratory 1 CFS Review of Asian Region (S. Fukuda) June 1/ Hz Operation in DRFS HLRF System KEK S. Fukuda.
MICE RF System Power Supplies, Control and Monitoring Status report February 2012 Chris White, STFC Daresbury Laboratory MICE Collaboration Meeting CM32,
September 19-20, 2007 R. Lambiase Power Supplies Bob Lambiase September 19-20, 2007 DOE Annual Review.
Linac RF Source Recommendations for Items 22,23,24,46,47 Chris Adolphsen.
Kévin Pepitone 1CLIC project meeting, CERN, December 1st, 2015 Kevin PEPITONE, BE-RF Drive Beam Injector Gun.
L-band test stations in End Station B Richard Swent.
Modulators for DB klystrons: requirements and plans for developments Serge Pittet, David Nisbet TE EPC.
HLRF Webex09 (April.3, 2009) 3/4/ Distributed RF-source Scheme (DRFS) First Design Shigeki Fukuda (KEK) Introduction Possible RF-source General Cost.
12 GHz Stand alone power source. Provisional Klystron Parameters ParametersSpecificationsunitsObservations RF Frequency12 (11.4)GHz Peak RF power50 -75MW.
NEXT EXCELLENCE IN SOLID STATE PULSED POWER BY SCANDINOVA SYSTEMS AB Klas Elmquist.
Xbox and Structure testing news N. Catalan Lasheras, R. DeGiovanni, J. Giner-Navarro, G. Mcmonagle, I. Syratchev, B. Wooley, X. Wu
Tao Tang, Craig Burkhart
EE 2353 HIGH VOLTAGE ENGINEERING
6. Unregulated Power Supply Design
Kévin Pepitone 1CLIC workshop, CERN, January 2016 Kevin PEPITONE, BE-RF LEETCHI: Drive Beam Electron Source.
Long Pulse Klystron Modulators SML (Stacked Multi-Level) topology
June 16, 2015 CLIC WORKSHOP JANUARY 18 – 22, 2016 OPTIMIZED RF UNIT I 1 January 21, 2016 By: Mikael Lindholm.
New prototype modulator for the European XFEL Project (DESY) Pulse Step Modulator (PSM) Technology for long pulse applications.
High Voltage modulators ESS developments Carlos A. Martins ESS Accelerator Division, RF electrical power systems.
Presentation CERN SPAIN | ITALY | FRANCE | GERMANY | MEXICO | USA | BRAZIL | UAE | QATAR | OMAN | SAUDI ARABIA jema.es.
CERN LHC RF Power Systems
Carlos A. Martins ESS – Accelerator Division - RF Electrical Power Systems May 16 th, 2014 Klystron and IOT modulators.
HLRF Post-TTC Meeting (Fukuda)
ILC Power and Cooling VM Workshop
EE 2353 HIGH VOLTAGE ENGINEERING
KEK Marx-Modulator R&D
MICE RF System Power Supplies, Control and Monitoring Status report
MEDIUM VOLTAGE APPLICATIONS.
Development of a Marx-Generator for the drive beam electron gun
Q &A for the questions from CFS of April 29,2011
Construction and Commissioning of Electronic Test Benches
Schematic diagram of part of a house wiring system
Visit for more Learning Resources
DRFS and Low Energy 10 Hz Option
AC Inlet & AC Input Filter
352MHz Klystron Control for the 3MeV Linac test stand
Fault detection Lecture (3).
SCANDINOVA IN UPPSALA, SWEDEN
Development of new power supplies for J-PARC MR upgrade
General presentation about recent status of DRFS
Toshiba 10 MW Multi-Beam Klystron (MBK)
Dr. Unnikrishnan P.C. Professor, EEE
Klystron Power Supplies for ILC
Power Semiconductor Systems II
LINAC PROTON SOURCE MODULATORS
Presentation transcript:

PS System for DRFS PS System for Diode-type klystrons M. Akemoto, KEK PS System for Diode-type klystrons PS System for Modulation-anode-type klystrons

PS system for Diode-type klystrons 2 3 (0V) 6.6 kVAC, 3φ VCB Transformer Input:6.6kV Output: 420V, 200V, 100V Klystron #1 Klystron #13 Marx Modulator Heater Trans. Oil Tank 7 1 HK HV cable Heater PS H Klystron Heater/Cathode HV Box #1 6 4 5 Control 8 6.6kV Main Power Line Klystron system connected to HV cables in parallel

Cost Estimation List No. Component Quantity Suppliers Specification 1 VCB Toshiba, Mitsubishi 6.6 kV , 3φ, 100 A fault current 2 Transformer Nichicon 6.6 kV, 3φ / 420 V,3φ, 200 V, 1φ, 100 V,1φ, 300 kVA 3 Marx Modulator DTI, SLAC, PPJ 67.5kV, 273 A, 2.4 ms, 5 Hz 4 Heater PS Matsusada,Takasago 134V, 18.3 A, 3 kVA, Constant current 5 Heater Trans. Oil Tank NTD 200 V AC, 3 kVA, 80 kV Isolation Trans. 6 Klystron Heater/Cathode HV Box 13 KEK, NTD HV floating 7 HV Cable - Fujikura RG-220/U , 150 kVAC 8 Control PLC, optical link

Marx Modulator 3 Performance requirements 67.4 kV peak voltage 273 A peak current 2.4 ms pulse width 5 Hz pulse repetition frequency +/- 0.5% flat top 221 kW average power <20 J deposited into klystron from gun spark Input voltage 3φ, 420 VAC, 50 Hz

PS system for Modulation-anode-type klystrons 6 2 3 Crowbar Circuit (0V) Droop compensation PS 6.6 kVAC, 3φ VCB Transformer Input:6.6kV Output: 420V, 200V, 100V Klystron #1 Klystron #13 Switching PS MA modulator MA Spark Gap Switch Anode Pulser 1 10 HK HV cable Heater PS H 4 5 Klystron Heater/Cathode HV Box #1 9 7 8 Control 11 6.6kV Main Power Line

Cost Estimation List No. Component Quantity Suppliers Specification 1 VCB Toshiba, Mitsubishi 6.6 kV , 3 phase, 100 A fault current 2 Transformer Nichicon 6.6 kV, 3φ / 420 V,3φ, 200 V, 1φ, 100 V,1φ 300 kVA 3 DC Switching PS Matsusada, Nichicon -65.8 kV, 166 kW 4 Capacitor bank 44 µF,-65.8 kV 5 Crowbar circuit Ignitron or gap switch 6 Droop compensation PS PPJ, Nichicon, Matsusada, DTI -13 kV, 263 A peak, 2,4 ms 7 Heater PS NTD 200 V AC, 3 kVA, 80 kV Isolation Trans. 8 MA modulator Nissin,Nichicon -53 kV, 2.4 ms, 5 Hz 9 Klystron Heater/Cathode HV Box 13 KEK, NTD HV floating 10 HV Cable - Fujikura RG-220/U , 150 kVAC 11 Control PLC, optical link

Summary We have designed two kind of PS Systems for DRFS. Now, we ask some companies to estimate the cost, size of the system components. We will compare them and decide the PS system for DRFS.