MICROSENS GmbH & Co. KG Kueferstr Hamm / Germany

Slides:



Advertisements
Similar presentations
10/100Base-TX to 100Base-FX Redundant Media Converter
Advertisements

2006 © SWITCH 1 TNC'06 Panel Presentation Myths about costs of circuit vs. packet switching Simon Leinen.
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
BOTU Features and Applications Copyright © Siemens Schweiz AG 2007.
LambdaDriver ™ family Wave Division Multiplexing.
Orion Telecom Networks Inc Slide 1 16 E1 + Gigabit Ethernet (Wire-Speed) Optical Multiplexer Updated: Jan, 2011Orion Telecom Networks Inc
3U ATCA Shelf October Proprietary and Confidential-
STM-1 ADM and TM.
Paweł Pilewski Pre-Sales Engineer MICROSENS GmbH & Co. KG
ATM FALCON Product Presentation ATecoM GmbH Pascalstr. 67 D Aachen Germany.
Copyright : Valiant Communications Limited Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Product Presentation.
10/100/1000Base-T to Dual 1000Base-X SFP Media Converter GT-1205A Icon5Icon4Icon3Icon2Icon1.
Net Optics Confidential and Proprietary 1 iLink Agg.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
DKTCOMEGA EDFA Product Line Jesper Broszka, Product Manager.
MC-1610MR / MC-1610MR48 16-Slot Managed Media Converter Chassis Copyright © PLANET Technology Corporation. All rights reserved.
Raisecom CWDM Products.  OPCOM Channel CWDM products  OPCOM Channel CWDM products  OPCOM Channel CWDM products  OPCOM200 product.
MSAP Specification (Preliminary) August 2007 NexComm.
Slide 1 Orion Telecom Networks Inc Slide 1 VCL-MX Version 2 – DLX (Deluxe Version) xcvcxv Updated: September 2010Orion Telecom Networks Inc
E1 / T1 Series Product Introduction.
| IPV-MUX-S | IP Gateway. |2|2 | IPV-MUX-S IP Gateway Line Ports | 10/100BaseT Ethernet auto-negotiation | Fiber Optic Module, 100BaseFX |1300nm Multimode.
Reconfigurable OADMs Reconfigurable OADM (ROADM)
Intorduction to Lumentis
FMUX01-A Copyright (c) 2003, 2004, CTC Union. All rights reserved.
Company confidential Koby Reshef. Company confidential Connect antennas to the base stations or BBUs with reduced fiber resources by factor 8 (or more)
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC PUBLIC CO900H L02 - Applying Basic EtherNet/IP Features in Converged Plantwide.
Industrial Ethernet active portfolio All models available in standard temperature variants 0°C to +60°C and extended temperature variants -40°C to +75°C.
Industrial Ethernet Switches. Industrial Ethernet Target Markets/Applications Security/surveillance providers – Backhaul IP camera video, alarms Utilities.
VCL-SE IEEE-1588v2 PTP Protected Synchronous Packet-Optical Transport Interface Presentation.
Application Note Fiber Connectivity Riedel solutions for broadcast applications 1 Application Note - Fiber Connectivity.
Application Examples – (C)WDM Fiber Accessories Riedel solutions for broadcast applications 1 Application Examples – (C)WDM Fiber Accessories.
RASPFiber Fiber Optic Network Switch. RASP-MG SC-A Managed gigabit switches, 1 fiber SC port, 5 UTP ports, TX1550nm/RX1310nm, single fiber, single.
© 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HP ProCurve 2910 Series Switches.
KBC Networks 2010 Fibre optic Wireless Broadcast Network Transmission Welcome.
Product Introduction Program
High Speed Interconnect Project May08-06
Digital Access Cross Connect Switch
New products introductions
High Speed Interconnect Project May08-06
24-/48-port 10/100/1000T + 4-port 10G SFP+
12 E1 Voice & Data Multiplexer
Broadband Communication Solution
Ethernet over DS3 Switch
Ethernet Switch Solution
Media Conversion Solution
Broadband Communication Solution
Intro to MIS – MGS351 Network Basics
Industrial Ethernet Solution
Product Presentation Ethernet over Multi E1 (4 / 8 / 16 E1)
Industrial Ethernet Solution
Ethernet Switch Solution
Media Conversion Solution
Media Conversion Solution
Valiant Communications Limited
SFP Bi-Di Transceiver FIBER OPTIC L2 SWICTH FCC PRODUCT SPECIFICATION
it.de/de/produkte/blueoptics/transceiver/sfpplus.html
Broadband Communication Solution
FIBER OPTIC TCP IP LINK 10/100Mbps
Data Center Paweł Pilewski Pre-Sales Engineer
MICROSENS_Get Connected
Broadband Communication Solution
Network Basics Extended Learning Module E
100G Optical Transmission The next evolutionary phase
Flexible Transport Networks
Business Data Communications, 4e
Brandywine Communications 2018 Sales Meeting Cody WY May 15/
VCL-MX™ Version 2-DLX (Deluxe Version) 4 x E1, 30 Channel Drop-Insert
VCL-MX™ Version 3-STD (Standard Version)
Presentation transcript:

MICROSENS GmbH & Co. KG Kueferstr. 16 59067 Hamm / Germany Optical Networks xWDM Platform MSP 1000 MICROSENS GmbH & Co. KG Kueferstr. 16 59067 Hamm / Germany V.2014-03

Chassis User Transponder User Transponder Dark User Fiber NMS PS MSP 1400 setup Chassis Fans PS User SFP Transponder User Mux XFP Transponder User Dark Fiber De- Mux NMP SNMP Browser NMS Filter AC / DC

MICROSENS WDM MSP - Platform Both chassis can be connected in many ways and use one common network management system (nmp). The same transponders and filters are used in both platform types. Each platform type can be used for CWDM & DWDM up to 10 Gbit/s per channel.

19“ Chassis MSP 1100 1 RU high, 19“ wide 2 slots for active cards Redundant fans Redundant Power Supply input 48V DC, external supplies for 230V AC Managed with MICROSENS nmp

19“ Chassis MSP 1400 4 RU high, 19“ wide 3 managed, field replaceable fans on the rear side 10 slots for active (and/or passive) cards Power Supplies 2x 230V AC, 2x 48V DC or 230V AC+ 48V DC Managed with MICROSENS nmp

Each Chassis MUST have a NMS Module MSP 1100, MSP 1400 Each Chassis MUST have a NMS Module A Chassis can have 1 PS (no redundancy) or 2 PS (fully redundant) Free airflow must be guaranteed: MSP 1100: from left to right MSP 1400: from front to back Passive modules (filters, etc.) can also be built in separate passive Chassis (1RU, 3 slots).

NM3 module Web Manager (HTTP/HTTPS) Command Line Interface via Telnet/SSH/Console SNMP v1/v2c/v3 with View-based Access Control Model (VACM) and User-based Security Model (USM) Linux operating system Users can be authenticated by the central TACACS+ server and user access may be restricted via Access Control List (ACL) User authentication according to IEEE 802.1X

Transponder Modules front view MICROSENS Module Name Module Description SFP Slots Port LEDs

Transponder Modules up to 4 Gbps X2G 2 Channels 2 Wavelengths 3R: 100 Mbps – 2,67 Gbps Cross-Connect A/B, A/B/C switch Backup 4x SFP MM/SM 850nm, 1300nm 100BaseT, 1000BaseT CWDM, DWDM M2G TDM function 2 Channels input 1 Wavelength output FC-1G, GbE Backup 4x SFP MM/SM 850nm, 1300nm 1000BaseT CWDM, DWDM T4G 2 Channels 2 Wavelengths 3R: FC-1G/-2G/-4G, GbE

M2G TDM for 2 Gigabit interfaces Input 1,0625 / 1,25 Gbps One card type for all port combinations Link speed fixed at 2,55 Gbps All interfaces standard SFP Synchronisation channel includes Remote Inband Management Built-in basic Performance Monitoring Automatic Link-Backup enabled through SW-Key (Backup-Key) Always „Point-to-Point“ NEW: E1/T1 Copper SFPs for P2P over GbE connection

TXG / CXG CXG: Single channel converter for 8G/10G, no 3R TXG: Single channel converter for 10 Gbps with 3R Both interfaces use XFP 3R on both ports with TXG All standard 10G speeds per can be selected by SW parameter: Ethernet, SDH/SONET, Fibre Channel (TXG) Supports tunable DWDM-XFP

NEW: CXG+ 4 SFP+ interfaces „Any“ speed up to 16 Gbps Transparent mode, no 3R Dual converter Point-to-Point, Ring, Star und meshed configurations Distances depending on type of SFP/SFP+ and application protocol/speed For best performance use SFP+ with integrated CDR

Pluggable Interfaces SFP / SFP+ / XFP All interfaces on all Transponder Modules are SFP / SFP+ / XFP Support of optical and electrical SFP SFP / SFP+ / XFP are not coded Transponder Modules X2G, M2G, T4G support SFP Transponder Modules TXG, CXG support XFP Transponder Module CXG+ supports SFP+ Tunable DWDM XFP are also supported (C-Band)

Modular CWDM Filters Always Mux + Demux per unit Always LC connectors Channel spacing 20nm Bandwith 11nm 8 channels 8 channels + Extension 5 channels + Extension + Expansion Up to 16 Wavelengths Can partially be combined with DWDM filters

Optical Power Monitoring Module OM1 Optical Power Level monitoring device Full Duplex (Tx/Rx) Single Lambda, CWDM, DWDM Power Level range +20 dBm up to -40 dBm Resolution 0,1 dB Software definable alarm levels No active parts in the link No data monitoring possible Link attenuation only 0,5 dB Link Monitoring Intrusion Detection QoS documentation

Fiber Security Solutions OM1: Monitoring of link attenuation OM1 OM1 DWDM DWDM NMP

Fiber Security Solutions OM1: Information available in NMP Current value Time since last threshold violation How long and how often… Thresholds configuration

Fiber Security Solutions OM2: Spectrum Analyser The OM2 is a standalone Spectrum Analyser. It can be connected to CWDM / DWDM links without interruption and then monitor the different wavelengths

Fiber Security Solutions C/DWDM Optical Spectrum Analyser (OM2)

Thanks for your attention! 20