Above and below the diaphragm

Slides:



Advertisements
Similar presentations
Advanced Biomedical Imaging Lecture 3
Advertisements

X Rays Medical Physics Notes.
Image Reconstruction.
Beam Therapy Equipment 2 Linear Accelerator Head.
{ Projection Radiography Chapter 5 (in more detail)
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
The Tomotherapy Experience at Advocate Good Samaritan Hospital
Photon Beam Monitor-Unit Calculations
Dose Calculations A qualitative overview of Empirical Models and Algorithms Hanne Kooy.
Maria Skłodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland 8th ECMP, Athens, Dosimetry audits in radiotherapy.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
Conformal Radiotherapy for Head and Neck Cancer Conformal Radiotherapy in Head and Neck Cancer B. Schicker, U. Götz, I. C. Kiricuta ISRO-Limburg - Germany.
Para-spinal Tumors Encircling the Spinal Cord IMRT Comparison of Several Target Definitions.
TREATMENT PLANNING PHOTONS & ELECTRONS Karen P. Doppke 3/20/2007.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Instrumentation Part 1.
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
tomos = slice, graphein = to write
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
At the position d max of maximum energy loss of radiation, the number of secondary ionizations products peaks which in turn maximizes the dose at that.
Electron Beams: Physical Principles and Dosimetry
Beam Therapy Equipment 3 Patient Treatment and Accessories.
Ch .4 Clinical Radiation Generators
Radiotherapy Treatment Planning
Quality Control Rad T 110.
Dose Distribution and Scatter Analysis
بسم الله الرحمن الرحيم و قل رب زدنى علماً ﴿و قل رب زدنى علماً﴾ صدق الله العظيم.
Treatment Planning Hodgkin Lymphoma.
Quality Control in Radiation Therapy, A New Concept: Dosimetry Check
Научно-практический центр протонной лучевой терапии и радиохирургии (Москва-Дубна) A SYSTEM FOR MEASUREMENT OF A THERAPEUTIC PROTON BEAM DOSE DISTRIBUTION.
External Beam Radiotherapy
Patient Plan Results: Table 3 shows the ratio of the Pinnacle TPS calculation to the DPM recalculation for the mean dose from selected regions of interest.
AUTHORS (ALL): Huang, Xiaoyan 1, 2 ; Kuan, K M 2 ; Xiao, G L 2 ; Tsao, S Y 3, 2 ; Qiu, X B 2 ; Ng, K 2. INSTITUTIONS (ALL): 1. Radiation Oncology, Sun.
Radiation Protection in Radiotherapy
Resident Physics Lectures
MONTE CARLO BASED ADAPTIVE EPID DOSE KERNEL ACCOUNTING FOR DIFFERENT FIELD SIZE RESPONSES OF IMAGERS S. Wang, J. Gardner, J. Gordon W. Li, L. Clews, P.
Using Radiation in Medicine. There are 3 main uses of radiation in medicine: Treatment Diagnosis Sterilization.
Fundamental Dosimetry Quantities and Concepts: Review Introduction to Medical Physics III: Therapy Steve Kirsner, MS Department of Radiation Physics.
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Hodgkin’s Lymphoma in Young Female Patients Can be Safely Treated with Radiation: A New Technique That Avoids The Breasts And Decrease The Heart Dose.
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
Radiation Quality Chapter 4. X-ray Intensity Intensity: the amount of energy present per unit time per unit area perpendicular to the beam direction at.
Part VIII:Medical Exposures in Radiotherapy
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
Interaction of x-ray photons (and gamma ray photons) with matter.
RTT 425 Radiation Therapy Physics Radiation Quality, Chapter 4 From Stanton and Stinson: Applied physics for Radiation Oncology.
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
Date of download: 6/23/2016 Copyright © 2016 SPIE. All rights reserved. (a) Relative positions of the linear accelerator (LINAC) gantry, treatment region,
Chapter 5 Central Axis Depth Dose Calculations. 2 Definition of Beam Geometry The accurate delivery of a radiation dose to patient depends on the precise.
Treatment Chart Record of patients radiation therapy history. Must contain: History and diagnosis Rationale for treatment Treatment plan Consent Documentation.
Mathematics for Computed Tomography
Chapters 21 & 22.
CHAPTER 3 DOSE DETERMINATION FOR EXTERNAL BEAMS
The physics of Radiation Therapy, pp
Electron Beam Therapy.
Optimisation of Patient Protection for Radiography
Khan, The Physics of Radiation Therapy, Ch7
Ch 7. Quality of X-ray Beams
Evaluation of the AAA Treatment Planning Algorithm for SBRT Lung Treatment: Comparison with Monte Carlo and Homogeneous Pencil Beam Dose Calculations 
Factors Effecting the Production
أجهزة العلاج الإشعاعي Clinical Radiation Generator
X-Ray Physics Assumptions:
Karla Leach, BS, CMD Texas Center for Proton Therapy-Irving, TX
Implementation of Object Spot Avoidance in Proton Pencil Beam Treatment on Whole Breast with Implant Metal Injector Peng Wang, PhD, DABR, Karla Leach,
Lecture 6: Attenuation and Transmission of Photons
Resident Physics Lectures (Year 1)
Ch 10. A System of Dosimetric Calculations
X Rays Medical Physics Notes.
Resident Physics Lectures (Year 1)
Hot and cold spots are common problems associated with planning:
Principles and Practice of Radiation Therapy
Presentation transcript:

Above and below the diaphragm Hodgkin’s Lymphoma Treatment Planning Above and below the diaphragm Why is it so complex? Patty Sponseller, CMD

It’s just AP/PA right? Mantle Para-aortics

Although AP/PA a lot going on here!

Radiation Fields Mantle covers chin and just below diaphragm Laterally “flash” skin to include both axilla Involved field radiation Inverted Y covers paraaortic, pelvic and inguinal lymph nodes

Mantle RT Radiation to a large area of the neck, Chest and axilla Cover all the main lymph node areas above the diaphragm Shielding to part of the lungs, heart and shoulders Mantle is derived from the name of a garment much like a cloak in medieval times

Variation with the DD throughout the fields PATIENT THICKNESS CHANGES PATIENT CONTOUR IRREGULARITIES DIFFERENT HETEROGENITIES MISSING TISSUE BEAM CHARACTERISTICS GEOMETRIC MATCH

Basic dose distribution data is obtained under standard conditions Homogenous density in a water phantom Perpendicular beam incidence Flat surface Why is this?

During Treatment The beam may be obliquely incident with respect to the surface Surface may be curved or irregular in shape Under these conditions, standard DD are not applicable without corrections

Corrected in Pinnacle

Beam data includes profile scans across the beam, depth doses and output factors (ratio of the dose measured for a specific F S standard to a 10 cm2) measured for every machine energy and many square field sizes. This measured data is used to determine the many, many free parameters in the Pinnacle model for EACH linear accelerator. In Pinnacle we are then modeling the energy that comes from the head of the Tx unit including all the scatter within the head that affects the energy spectrum.

Modeling – Convolution Algorithm An integral that calculates at every point within the dose grid. That dose calculation includes the attenuation of the beam as it travels through tissue times the energy fluence of energy spectrum times the energy kernel.

Convolution Algorithm

Want to know more?

Imaging Conventional X rays Ultrasound CT scan PET (FDG) Ability to screen for distant Dz Uptake in nodal areas that look normal on CT False positives Not good at detecting marrow involvelment

Simulation for Adjacent Fields Maintain patient position when all fields are treated Proper immobilization for entire torso Clam shell used if pelvis RT for males Consider oophoropexy for females Supine position with arms akimbo Immobilization indexed to treatment couch

Matching new fields with previously TX Tattoo documentation cannot be overemphasized Compare prior DRR’s and portal images Examine the chart carefully for possible changes during prior RT Reproduce prior RT with new scan to ensure which segment of spinal cord was irradiated

Goal is a Homogenous Dose Distribution Adjacent fields have the same divergence

Adjacent Fields Adjacent fields do not match divergence Dose discrepancies over spinal cord

Inverted Y May need to split up inverted Y into 2 fields for adult or tall adolescent Otherwise-

Paraortics/Spleen

You have this problem The larger inverted Y does not match the divergence of the mantle field Hot and cold spots

Blocking Spleen/Paraortic Fields or Inverted Y usually can accommodate MLC Mantle Fields typically are a combination of MLC and Cerrobend blocking Lung Block shapes are usually too complex for MLC May consider a larynx block on AP field

Combination of MLC’s and custom blocks

Portal Imaging See the combination here

Field Blocks Blocks are shaped or tapered to match the divergence of the beam This minimizes block transmission pneumbra (partial transmission of the beam at the edges of the block) Do we do this for all our photon blocking at UWMC?

Custom Blocking Lipowitz Metal Cerrobend (brand name) Approx 83% of Pb density Low melting point Materials making up Cerrobend are Bismuth Lead Tim Cadmium

How thick are the blocks? Half Value layer The thickness of the material required to attenuate the intensity of the beam to half its original value How many HVL’s in MV photon blocking?

Original Value 100% 50% 25% 12.5% 6.25% 3.12% 1.56% 5 HVL’s

How thick are the blocks? 5 HVL’s of Cerrobend needed What is the HVL thickness of Cerrobend? 1 HVL of Cerrobend is 1.5 cm thick In the megavoltage range of photons the most common used thickness is 7.5 cm Which is equivalent to about 6 cm of pure lead

Mantle Fields Dose Distribution is calculated with cerrobend blocking Pinnacle will not allow Step N Shoot with custom blocking Here we use a “Poor Man” Technique Treat more than one field, close jaws and adjust weighting

Other Techniques Use wedge on AP field if FS allows Compensators Decimal

Para/Spleen or Inverted Y Usually MLC’s can be used for blocking on all fields May require Step N shoot for hot spots

Point under a block 17 cm 4.5 cm 6.25 cm 17 cm

Fields 17 X 17 cm = 17 cm 2 4.5 x 17 cm= 7 cm 2 6.25 x 17 cm= 9 cm 2 Calculate the dose under a block at 10 cm depth

Which blocks are bettter?