The ultimate chain lubrication system. LC – Low Cost Lubrication Kits

Slides:



Advertisements
Similar presentations
Instructional Presentation
Advertisements

Introduction to Pneumatic Components Build a Working Pneumatic Circuit
CHAPTER 45 Engine Lubrication.
Operation of the FW-720 Unit 1. Side 1 2 Inlet Hand Crank.
Engineer Training XL1200 Ink System. Engineer Training XL1200 Ink System Confidential 2 Ink System The XL1200 Ink System consists of the following elements:
Water Hydraulic Valves
ADX 150 – Engine Repair ADX 170 – Climate Controls
Manual Flo-tap Installation Instructions
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Installation. Indoor Unit Installation Typical Installation.
Unit Ten Directional Control Valves
Lubrication Of Roller Bearings. Roller Bearings have a long history around 700 BC AC around 3000 BC.
Technical support provided by: Highly Pathogenic Avian Influenza Control Programme SOP Use and Maintenance of High Pressure Washer Machine Market chain.
Yamaha oil pump rebuild
TrueSTEAM™ Humidification Systems Module 3: Basic Installation.
ZepZep C4 Entryway Foam System uctionInstruction Manual
Oxygen Concentrators.
Introducing the Mobile Sink with Cabinet Base and Self Contained Water Supply BH, Inc.
1 USING MOLLART SPRAY MIST SYSTEM. 2 SETTING UP IN CONVENTIONAL MANNER DATUM YOUR PART AS NORMAL PROCEDURE.
Gear Drive Flo-tap Installation Instructions Quick Installation Guides: rev. EA – 485 Flanged Flo-tap rev. DB – 485 Threaded.
ResQmax Line Deployment Kit -ResQmax Launcher- 5 nozzle protectors -2 Streamline Projectiles- O-ring kit -500’ 3mm line with container- Corrosion block.
Complete Cryogenic Services, Inc.
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
Unit 206: Domestic hot water systems
Actuators.
PowerStream / Jonathan Smith / Your « One-Stop-Shop » for machine-tool peripherals PowerStream SA.
Hydronic Mechanical Controls
Asahi/America Type 21 Ball Valves Type 21 Ball Valves.
1 Fuel Pumps. 2 Pumps 1.All oil burners for residential heating have pumps A. They are connected to a motor through a coupling 2.Description A. An oil.
Asahi/America Thermoplastic Check Valves Ball Check Valves ½” - 4”PVC, CPVC, PP, PVDF Uniseat/ Seal.
HVAC523 Circulator Pumps.
VC Training Table Setup and Floating Agenda General –Air Supply Requirements Assembly –Assembling the System –Leveling the Table –Isolating.
1 Skill Drill 2-7 Donning a Face Piece Step 1: Fully extend the straps on the face piece. Step 2: Place your chin in the chin pocket. 2 Step 3: Fit the.
Module-6 Drilling.
Honda Fit Turbo Kit Installation Manual. Take off windshield wiper.
Pneumatic and hydraulic actuation system (cont.)
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
Framed Canopy Fitting Instructions Contents – 6- Angled frame fixing brackets 1 x handle pack 6 x self drilling tech screws 3 keys 1x door 6 x coach screws.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
Natura Water Machine B and D Series 3 – Dispense tower plumbing kit Kit number Kit includes components used for both Natura B and Natura D series.
XAS 375 CD6 Compressors Committed to sustainable productivity
Grapple Housing Top Sub Grapple Collet Seal Housing Bottom Sub Seal Housing Metal Seal Ring.
IMPLEMENTATION LOCATION VARIABLE AXIS LUBE VARIABLE SPINDLE LUBE PARAMETERS ELECTRICAL SERVICE MINIMAL LUBE SYSTEM.
Plumbing Valves.
Coffee Dispenser Specifications and Installation Requirements.
Chicago Pneumatic Compressors Company Presentation
Quick Start Guide for Flex Flow Pump
Air Pak Drying Systems Presented By: Dry Air Systems, Inc. Innovator of Unique Regenerative Desiccant Air Dryers For Compressed Air & Fluid Power Controls,
Scorpion is a remote tester specifically designed for testing ASD systems. Scorpion is compatible with the FAAST aspirating smoke detector. It is particularly.
Engine Lubrication Systems
Octopot Single Auto Fill System Octopot.com
Pneumatic and Hydraulic
© Copyright, HQT-SV Control System
Presented by:- ARAVIND P V MS S5 NO:-60
BLOWING AND RINSING UNIT
Welcome to Malaga WeBex سیستم سوخت رسانی ریل مشترک کاتر پیلار
C Air Compressor Up-fit and Plumbing Guide For LDI B3
LUBRICATION METHODS.
Vertical Pressure Filters
INTRODUCTION TO PNEUMATICS
CHAPTER 45 Engine Lubrication.
Device Photographs.
Hot Water Systems Cylinders and Systems.
Customer Presentation
Introduction of fuel feed system
TRENTON Casing Filler Presentation
Dip. Software based statistics PhD ( physiology), FICA , IDRA
Chapter 13 Lubrication.
Presentation transcript:

The ultimate chain lubrication system. LC – Low Cost Lubrication Kits Extend Chain Life not the Chain – Improve Cleanliness –Reduce Amps – Reduce Oil consumption

RotaLube LC Lubrication Kits . Kit Part Number  Kit Description. RSL-LC-200-08B1 Oil Pump (0.2 Ltr) with ½” BS Applicator RSL-LC-200-10B1 Oil Pump (0.2 Ltr) with 5/8” BS Applicator RSL-LC-200-12B1 Oil Pump (0.2 Ltr) with 3/4” BS Applicator RSL-LC-200-16B1 Oil Pump (0.2 Ltr) with 1” BS Applicator RSL-LC-200-20B1 Oil Pump (0.2 Ltr) with 1 ¼” BS Applicator RSL-LC-200-24B1 Oil Pump (0.2 Ltr) with 1 ½” BS Applicator   RSL-LC-1000-08B1 Oil Pump (1.0 Ltr) with ½” BS Applicator RSL-LC-1000-10B1 Oil Pump (1.0 Ltr) with 5/8” BS Applicator RSL-LC-1000-12B1 Oil Pump (1.0 Ltr) with 3/4” BS Applicator RSL-LC-1000-16B1 Oil Pump (1.0 Ltr) with 1” BS Applicator RSL-LC-1000-20B1 Oil Pump (1.0 Ltr) with 1 ¼” BS Applicator RSL-LC-1000-24B1 Oil Pump (1.0 Ltr) with 1 ½” BS Applicator LC- Low Cost Rotalube Lubrication systems supplied in a kit.

LC- Low Cost Rotalube Lubrication systems supplied in a kit. LC Lubrication Kits . Quantity Part Number Description 1 RSL-LC-1000 Or RSL-LC-200 Pneumatic Lubrication Pump complete with 0.2 litre or 1 Litre Reservoir. Reservoir has oil sight gauge attached and pump air/oil outfeed is supplied with 2m of 6mm OD feed Pipe RSL-LC-B1 RSL-LC-B2 Mounting Bracket for the pump See attached- For options Rotalube applicator with one 6mm OD push fit inlet fitting. LC- Low Cost Rotalube Lubrication systems supplied in a kit.

LC- Low Cost Rotalube Lubrication systems supplied in a kit. RotaLube Applicators . Chain Size Part No A (mm) B (mm) C (mm) D (mm) E (mm) Inlet (mm) 3/8” RSL-LC-06B1 38 19 Ø10 16 Ø40 Ø6 O.D 1/2” RSL-LC-08B1 41 Ø44 5/8” RSL-LC-10B1 40 Ø46 3/4” RSL-LC-12B1 44 21 Ø48 1” RSL-LC-16B1 53 25 Ø56 1 1/4” RSL-LC-20B1 58 28 Ø66 1 1/2” RSL-LC-24B1 68 33 Ø76 LC- Low Cost Rotalube Lubrication systems supplied in a kit.

LC- Low Cost Rotalube Lubrication systems supplied in a kit. Installation . Mount the LC Lubrication pump onto the bracket provided. Connect the air supply, air supply to be manually controlled by an on/off isolation valve or electrically by solenoid valve. The Solenoid valve could be controlled by a controller or machines PLC. Solenoid or manual ball valve are not included in the kit. Ensure the air is off at this point. Mount the Rotalube onto the chain , detailed in the Installation section The applicator must be no further than 2M from the lubrication pump. 4. Simply connect the feed line that is attached to the pump to the Rotalube inlet. The inlet is 6mm OD push in . Fill the Reservoir with recommended oil as detailed in on Page 7 . Once the pump has oil in the reservoir and the filler nipple sealed allow regulated air supply to the pump. The air pressure must be less than 20PSI. The system will take approximately 1-2 minutes to prime and then the feed pattern can be seen at the Rotalube applicator. Should the air oil feed from the applicator be too much –reduce the air pressure into the pump. Each application will have its own optimum air pressure requirement and this will be anywhere between 5 and 20 PSI LC- Low Cost Rotalube Lubrication systems supplied in a kit.

Installation of the Applicator . Directions for correct mounting of Timken ILS Ltd RotaLube Applicators – It is vital that the RotaLube Applicator is installed by following these instructions. Failure to adhere to the following will result in the RotaLube Applicator not functioning correctly . Each RotaLube applicator has an exterior indication of the position for correct installation identified by a drilled spot located directly below the two mounting holes (as shown). The RotaLube Applicator MUST be positioned on the chain with the mounting holes in a horizontal plane and the location pin pointing directly down onto the chain link/pin. Never rest the RotaLube directly onto chain roller, Always have the applicator mounted off the roller Mounting holes. Indicator to show Direction of the lubricant feed. LC- Low Cost Rotalube Lubrication systems supplied in a kit.

Rotalube LC Specified Lubricants . To Fill the LC Lubrication Pump – Isolate the air from the pump Remove the Filler Plug at the top of the pump head as shown Fill with the recommended Lubricant Lubricant supplied in 500cc bottles fitted with twist lock directional spouts. LC- Low Cost Rotalube Lubrication systems supplied in a kit.

Suitable Lubricants for The Application . Quality, lubricants suitable for penetrating Chain with good lubricating properties .Operates well in the LC lubrication systems Resulting in reduced chain wear and friction, reducing power consumption and increases service life. Lubricants Chain Oil for Rotalube LC Pumps & Applicators  Pack RSL1-ISO UV32-500 High Performance Chain Oil x 6 KluberOil 4UH1-N-500 Food Grade Oil H1 approved Extend Chain Life not the Chain – Improve Cleanliness –Reduce Amps – Reduce Oil consumption

Simple Installation . Extend Chain Life not the Chain – Improve Cleanliness –Reduce Amps – Reduce Oil consumption