Respirator Terminology

Slides:



Advertisements
Similar presentations
OSHA’s Respiratory Protection Standard 29 CFR
Advertisements

Hazardous Materials Section Five: Scene Safety, PPE and Scene Control
NPPTL Year Month Day Initials BRANCH Overview of NIOSH-Approved Respiratory Protection Devices.
RESPIRATORY PROTECTION By Office of Risk Management Loss Prevention Unit.
RESPIRATORY PROTECTION
OSHA’s Respiratory Protection Standard 29 CFR
Respiratory Protection
Respiratory Protection HS 432 "Protective equipment … shall be provided, used, and maintained in a sanitary and reliable condition whenever it is necessary.
BLR’s Safety Training Presentations
Respirators should only be used as a "last line of defense" when engineering control systems are not feasible. Engineering control systems, such as.
Respirator Program.
Respirator Selection based on OSHA APFs
OSHA’s Respiratory Protection Standard 29 CFR
Respiratory Protection Program 29 CFR
E VERY L IFE H AS A P URPOSE… Major Requirements of OSHA Respiratory Protection Standard 29 CFR Greg Gatcomb E VERY L IFE H AS A P URPOSE…
Respiratory Protection Program (RPP) San Joaquin Delta College Revised: 10/05/2011.
OSHA’s Respiratory Protection Standard 29 CFR
Respiratory Protection TGA Safety Roundtable March 2015.
RESPIRATORY PROTECTION From Hazardous Atmospheres 29 CFR
Copyright  Progressive Business Publications Blue Ridge Safety Association Safety Training Presentations Respirator Safety.
Respiratory Protection
Topics of Discussion Responsibilities Respiratory System
RESPIRATORY PROTECTION
Risk Management Office’s Respiratory Protection Training
1. The 3M manufactures 2 types of Powered Air Purifying Respirator (PAPR) to be worn to provide respiratory protection for those staff members who have.
RESPIRATORY PROTECTION
Rowan University. Definitions High efficiency particulate air (HEPA) filter Immediately dangerous to life of health (IDLH) Negative pressure respirator.
Respiratory Protection Program 29 CFR Respiratory Protection Program When respiratory protection is necessary When respiratory protection is.
Safety Training Presentations
Respiratory Protection
Peoplefirst-us.com. Photos shown in this presentation may depict situations that are not in compliance with applicable OSHA/MSHA/FHWA requirements.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
RESPIRATORY PROTECTION STANDARD FEDERAL REGISTER 1/8/98 29 CFR Revised Other OSHA Standards That Incorporated By Reference.
Respirator Regulations  NIOSH 42 CFR Part 84  OSHA 29 CFR
R espiratory Protection In Compliance With: 29 CFR Cummins Southern Plains, Ltd.
HDOE Annual Respiratory Protection Training. OSHA’s Respiratory Protection Standard 29 CFR
Respiratory Protection 29 CFR Regulatory Requirements 29 CFR Covers all required and voluntary use of respiratory protection in general.
Respiratory Protection
Respiratory Safety Public Safety Murray State University.
 Defines standard operating procedures to ensure the protection of all employees from respiratory hazards  Includes: ◦ Selection and Use ◦ Cleaning.
RESPIRATORY PROTECTION
NIEHS – HMTRI Katrina Response Initiative 10/17/20052 U45 ES Safety Awareness for responders to Hurricane Katrina Operations: Respiratory Protection.
1/05 School Safety Training Respiratory Protection WAC /
Respirator Fit Testing and Training
Division of Risk Management State of Florida Loss Prevention Program.
OSHA’s Respiratory Protection Standard 29 CFR
RESPIRATORY SAFETY. Respirators Will Protect You + Hazardous particles in the air can cause serious injuries or death + Use a respirator whenever you.
3M FR-57 Gas Filter Cartridge. Fr-57 Filter Cartridge One piece of the PAPR (powered air purifying respirator) system Only compatible with 3M Breathe.
RESPIRATORY TRAINING. Objectives + Why are respirators are necessary + Capabilities & Limitations + Inspecting & Maintaining + Medical Clearance & Fit.
Respiratory Protection – Half and Full Face Cartridge Respirators Training on the use of respirators in the workplace – module 2 Developed by the Division.
Respiratory Protection Program
OSHA’s Respiratory Protection Standard 29 CFR
PPE Requirements for HHW Activities
Respiratory Protection Program Overview
Respiratory Protection
CTE Respiratory Protection Training
Respiratory Protection Training
Benzene.
Ensures compliance with OSHA 29 CFR
Respiratory Protection
Click anywhere to get started…
Respirator program Written by Ralph Hall.
BLR’s Safety Training Presentations
Welding Fumes and Gasses
Respirator program Written by Ralph Hall.
OSHA’s Respiratory Protection Standard 29 CFR
OSHA’s Respiratory Protection Standard 29 CFR
Disaster Site Worker Safety
OSHA’s Respiratory Protection Standard 29 CFR
Disaster Site Worker Safety
Presentation transcript:

Respirator Terminology Using the OSHA Definitions Handout

Name that TERM! Using OSHA Definitions Handout A filter that is at least 99.97% efficient in removing monodisperse particles of 0.3micrometers in diameter. A respirator in which the pressure inside the respiratory inlet covering exceeds the ambient air pressure outside the respirator. High efficiency particulate air (HEPA ) or N, R, P100 Positive Pressure Respirator

Name that TERM! Using OSHA Definitions Handout An atmosphere that poses an immediate threat to life, would cause irreversible adverse health effects, or would impair an individual’s ability to escape from a dangerous atmosphere. An atmosphere-supplying respirator for which the source of breathing air is not designed to be carried by the user. An air-purifying respirator that uses a blower to force the ambient air through air-purifying elements to the inlet covering. Supplied-Air Respirator (SAR) or Airline Immediately Dangerous to Life or Health (IDLH) Powered Air-Purifying Respirator (PAPR)

Name that TERM! Using OSHA Definitions Handout A quantitative estimate of the fit of a particular respirator to a specific individual, and typically estimates the ratio of the concentration of a substance in ambient air to its concentration inside the respirator when worn. A system that warns the respirator user of the approach of the end of adequate respiratory protection, for example, that the sorbent is approaching saturation or is no longer effective. End-of-Service-Life Indicator (ESLI) Fit Factor

Name that TERM! Using OSHA Definitions Handout An action conducted by the respirator user to determine if the respirator is properly seated to the face. An atmosphere with an oxygen content below 19.5% by volume. Any occurrence such as, but not limited to, equipment failure, rupture of containers, or failure of control equipment that may or does result in an uncontrolled significant release of an airborne contaminant User seal check Emergency situation Oxygen deficient atmosphere

Name that TERM! Using OSHA Definitions Handout A respirator with an air-purifying filter, cartridge, or canister that removes specific air contaminants by passing ambient air through the air-purifying element. A respirator intended to be used only for emergency exit. Escape-only respirator Air-Purifying Respirator or APR WHAT IS A HAZARD RATIO???

Hazard Ratios Maximum Use Concentration (MUC): means the maximum atmospheric concentration of a hazardous substance from which an employee can be expected to be protected when wearing a respirator, and is determined by the assigned protection factor of the respirator or class of respirators and the exposure limit of the hazardous substance. The MUC usually can be determined mathematically by multiplying the assigned protection factor specified for a respirator by the NIOSH recommended exposure limit (REL), permissible exposure limit, short term exposure limit, ceiling limit, peak limit, or any other exposure limit used for the hazardous substance.

Respiratory Choice Example 1: Contaminant X, a particulate, has been monitored in the workplace at 78mg/m3 during a 8 hour shift. It is an atmosphere containing oil, it is also an irritant for the eyes and skin. The workplace is located in a plant where there is no risk of oxygen deficiency. The PEL for contaminant X is at 10mg/m3 and IDLH is at 180mg/m3 Based on this information, here are the results for the Hazard Ratio calculation: Concentration 78mg/m3 divided by PEL 10mg/m3 = 7.8 Now let use the NIOSH/OSHA Selection Logic and see the result:

Respiratory Choice Example 2: 10 mg/m3 divided by 0.05 mg/m3 = 200 Contaminant Y, a fiber, measured at 10mg/m3 during an 8 hour shift. This product is classified as CARCINOGEN (Appendix A NIOSH) and the PEL is at 0.05mg/m3. The IDLH is 50 mg/m3 and it is an irritant for the eyes and skin. No risk of oxygen deficiency. Hazard Ratio will be : 10 mg/m3 divided by 0.05 mg/m3 = 200 What is going to be the respiratory selection?

Respiratory Choice Example 3: 70 ppm divided by 35 ppm = 2 Contaminant Z (Organic Vapour) monitored at 70 ppm for an 8 hour shift. With the help of certain data, (the EZ-Guide) the usage time of the cartridges have been evaluated at 8 hours in the workplace. PEL is at 35 ppm and the IDLH is at 250 ppm. The Hazard Ratio is : 70 ppm divided by 35 ppm = 2 The result with the Flowchart is:

Respiratory Choice Example 4: 60 ppm divided by 25 ppm = 2.4 Contaminant is Ammonia monitored at 60 ppm for an 8 hour shift, it is an irritant for eyes and skin. The PEL is 25 ppm and IDLH is at 300 ppm and the customer doesn’t have a clue on how long the cartridges are lasting. Hazard Ratio base on our calculation is: 60 ppm divided by 25 ppm = 2.4 The selection will be:

Do I Need A Full Face Respirator?

Do I Need A Full Face Respirator?