Report from WG2: Common Characterisation and Physics Issues

Slides:



Advertisements
Similar presentations
Status of test beam data analysis … with emphasis on resistive coating studies Progress and questions 1Meeting at CEA Saclay, 25 Jan 2010Jörg Wotschack,
Advertisements

Atsuhiko Ochi Kobe University 4/10/ th RD51 collaboration meeting.
Micro MEsh GASeous Detectors (MicroMegas)
Maximilien Chefdeville NIKHEF, Amsterdam RD51, Amsterdam 17/04/2008
GEM Detector Shoji Uno KEK. 2 Wire Chamber Detector for charged tracks Popular detector in the particle physics, like a Belle-CDC Simple structure using.
Readout of a TPC with the MEDIPIX2 CMOS chip as direct anode Saclay/DapniaP. Colas Y. Giomataris NIKHEFA. Fornaini H. van der Graaf J. Timmermans J. Visschers.
Kolympari, Crete, June 16, Study of avalanche fluctuations and energy resolution with an InGrid-TimePix detector P. Colas Progress report, based.
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
Status of PNPI R&D for choice of the MUCH tracking base detector (this work is supported by INTAS) ■ Introduction ■ MICROMEGAS ■ GEM ■ MICROMEGAS+GEM ■
WG1 summary P. Colas, S. Duarte Pinto RD51 Collaboration meeting in Bari October 7-10, 2010.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Fred Hartjes 1 6 th RD51 collaboration workshop, Bari (Italy), October 9, 2010 Gossip testbeam August 12 – 22, 2010 Maarten van Dijk Martin Fransen Harry.
First results of an aging test of a full scale MWPC prototype for the LHCb muon system Workshop on “Aging Phenomena in Gaseous Detectors”, October 2-5.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
HIGH RATE BEHAVIOUR AND DISCHARGE LIMITS IN MICRO-PATTERN DETECTORS A. Bressan, M. Hoch, P. Pagano, L. Ropelewski and F. Sauli (CERN, Geneva, Switzerland)
Geant4 Simulation of Neutrons interaction with GEM-foil and gas Gabriele Croci, Matteo Alfonsi, Serge Duarte Pinto, Leszek Ropelewski, Marco Villa (CERN)
An Integrated Single Electron Readout System for the TESLA TPC Ton Boerkamp Alessandro Fornaini Wim Gotink Harry van der Graaf Dimitri John Joop Rovekamp.
21 April 2004LCWS 2004 Paris1 Readout of a TPC using the Medipix2 CMOS pixel sensor (detection of single electrons on a direct pixel segmented anode) NIKHEF:
Timepix at NIKHEFMedipix meeting, CERN – Some recents results at NIKHEF M. Chefdeville, E. Bilevych, H. van de Graaf, J. Timmermans D. Attié,
5 th RD51 meeting (WG1) 25 May 2009 Atsuhiko Ochi ( Kobe University )
Digital primary electron counting: W, Fano Factor, Polya vs Exponential M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, October 2008.
Atsuhiko Ochi Kobe University
Preliminary results of a detailed study on the discharge probability for a triple-GEM detector at PSI G. Bencivenni, A. Cardini, P. de Simone, F. Murtas.
Piggyback seal Micromegas D. Attié, A. Chaus, D. Durand, D. Deforges, E. Ferrer Ribas, J. Galán, I.Giomataris, A. Gongadze, F.J. Iguaz, F. Jeanneau, R.
GEM basic test and R&D plan Takuya Yamamoto ( Saga Univ. )
1/18 01/26/2007MPGD Workshop in Saga (Yorito Yamaguchi, CNS, Univ. of Tokyo) 東大 CNS における GEM の基本動 作特性の研究 Measurement of basic properties of GEM at CNS,
1 InGrid: the integration of a grid onto a pixel anode by means of Wafer Post Processing technology 16 April 2008 Victor M. Blanco Carballo.
you me  when it all started to work  progress made  outlook.
Plans for MPGD Radiation hardness tests for full detectors and components Matteo Alfonsi,Gabriele Croci, Elena Rocco, Serge Duarte Pinto, Leszek Ropelewski.
1 Update on Silicon Pixel Readout for a TPC at NIKHEF LCWS08 - Chicago 19 Nov 2008 Jan Timmermans NIKHEF.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
1 Two-phase Ar avalanche detectors based on GEMs A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, Y. Tikhonov Budker Institute of Nuclear Physics,
GEM+Timepix2 in the framework of project Gabriele Croci, Matteo Alfonsi on behalf of CERN-GDD Group RD51 Miniweek, February 2010.
IEEE/NSS Oct 22, Electron Counting and Energy Resolution Study from X-ray conversion in Argon Mixtures with an InGrid-TimePix detector. D. ATTIÉ.
Collection of Photoelectrons from a CsI Photocathode in Triple GEM Detectors C. Woody B.Azmuon 1, A Caccavano 1, Z.Citron 2, M.Durham 2, T.Hemmick 2, J.Kamin.
T. Zerguerras- RD51 WG Meeting- CERN - February Single-electron response and energy resolution of a Micromegas detector T. Zerguerras *, B.
A.Ochi Kobe University MPGD2009 Crete 13 June 2009.
1 A two-phase Ar avalanche detector with CsI photocathode: first results A. Bondar, A. Buzulutskov, A. Grebenuk, D. Pavlyuchenko, R. Snopkov, Y. Tikhonov.
Single GEM Measurement Matteo Alfonsi,Gabriele Croci and Bat-El Pinchasik June 25 th 2008 GDD Meeting 1.
The digital TPC: the ultimate resolution P. Colas GridPix: integrated Timepix chips with a Micromegas mesh.
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
Fred Hartjes 1 RD51 mini week, CERN, June 14, 2012 Implementing GridPix in a Darwin detector Matteo Alfonsi, Niels van Bakel, Patrick Decowski, Harry van.
Gossip : Gaseous Pixels Els Koffeman (Nikhef/UvA) (Harry van der Graaf, Jan Timmermans, Jan Visschers, Maximilien Chefdeville, Vladimir Gromov, Ruud Kluit,
NSCL Proton Detector David Perez Loureiro September 14 th 2015.
R&D activities on a double phase pure Argon THGEM-TPC A. Badertscher, A. Curioni, L. Knecht, D. Lussi, A. Marchionni, G. Natterer, P. Otiougova, F. Resnati,
Large THGEM sampling elements for DHCAL status report
Max Chefdeville, NIKHEF, Amsterdam
An extension of Ramo's theorem to include resistive elements
some thoughts on charging-up effects
Gabriele Croci (CERN) GDD Meeting March, the 20th 2008
Part-V Micropattern gaseous detectors
WP5: Micropattern Gas Detectors
Single GEM Measurement
MPGD 2013 Conference,Zaragoza July 1-4, 2012
THGEM: Introduction to discussion on UV-detector parameters for RICH
Development of Hard X-ray Detector with GEM
Numerical simulations on single mask conical GEMs
Micro-Pattern Gaseous Detectors
Numerical simulations on single mask conical GEMs
TPC Paul Colas Technical meeting, Lyon.
Avalanche flutuations with InGrid/TimePix
Ionization detectors ∆
Development of Gas Electron Multiplier Detectors for Muon Tomography
Dan Burke1, P. Colas2, M. Dixit1, I. Giomataris2, V. Lepeltier3, A
MWPC’s, GEM’s or Micromegas for AD transfer and experimental lines
Development of GEM at CNS
Pre-installation Tests of the LHCb Muon Chambers
Micro Resistive Well Detector for Large Area Tracking
Gain measurements of Chromium GEM foils
A DLC μRWELL with 2-D Readout
Presentation transcript:

Report from WG2: Common Characterisation and Physics Issues Harry van der Graaf 2nd RD-51 Workshop, Paris, Oct 15, 2008

Discharge protection for MPGDs Martin Fransen, Nikhef

Gridpix detectors Grid made by lithographic procedure. (University of Twente) Drift volume (1mm-1m). Grid. Gain region. Pixel readout chip.

Gridpix detectors Slowing down the discharge. Reduce amount of charge. Spread the charge. Drift volume E= ~0.1-1kV/cm. Grid. Gain region E= ~80kV/cm Timepix chip.

High resistive coating Deposit on the chip without killing the electronics. Quenching of discharges. Some conductivity to prevent net charge build up. Amorphous silicon (IMT Neuchatel), SiProt. Si3N4 , silicon nitride (Twente), SiNProt. Provoke discharges with α radiation to test the layer.

Discharge quenching 3 µm a-Si. Dummy anodes. Peak currents: 6-7 amps on bare anode. 3-4 amps on prot. anode. Reduced heat dissipation. Bare anode Anode w 3µ a:Si

Pixelman software: IEAP, Prague Discharge quenching Slowing down the discharge. Reduce amount of charge. Spread the charge. Pixelman software: IEAP, Prague

Recent developments Charge per pixel reduced to ~ pC  Medipix 3 with input protection. chip with 7 µ SiNProt still alive after >10 days. At Twente both Ingrid and SiNProt can be applied!  post processing faster and cheaper. Discharge on a SiNProt covered Timepix chip.

Discharge test structure Foolproof test structures. To quantify: Time of discharge Amount of charge charge density distribution As function of: SiProt thickness Gas mixture Voltage

Fred Hartjes NIKHEF Magic or science? MPGD ageing Fred Hartjes NIKHEF Magic or science? 2nd RD51 collaboration meeting Paris, October 13 - 15, 2008

What is ageing of a gaseous detector? Loss of avalanche gain Rapid or slower Broadening amplitude spectrum => More variation in gas gain Increased sparking tendency => Damage on electrodes Secondary emission from cathode Increased dark current After pulsing Self-sustained discharge J. Va'vra, NIM A387(1997)183 F.Hartjes, MSGC damage

Loss of gain in gaseous detectors Figure of merit: accumulated charge on the anode surface Kadyk (I. Juricic, J.A. Kadyk, Proceedings Workshop on Radiation Damage to Wire Chambers, Berkeley 1986, p. 141) where Q is the accumulated charge per cm anode (wires or strips) or cm2 (MPGD, PPC, ….) G is the gas gain D is the dose (particles per cm resp cm2 ne is the primary ionisation per hit Define the ageing rate R (%/C/cm) or (%/C/cm2) as A is the average magnitude of the charge signal Example for wire chambers R = 1 %/ C/cm => excellent R = 200 %/C/cm => bad

Competition: ageing of silicon sensors Figure of merit: neq dose Damage from applied radiation converted into damage from radiation caused by 1 MeV neutrons => easy evaluation of radiation hardness Often using neutrons from nuclear plant for ageing characterisation Nature of silicon sensor damage Increase of depletion voltage Presently “solved” using oxygenated silicon (RD50 activities) Decrease resistivity Rock hard phenomenon => go to low temperature (-30 C) Decrease of the mean free path => practical limit for regular oxygenated silicon sensors 3*1015 neq / cm2 (Not speaking about 3D silicon, diamond, …..)

Field geometry of most common gaseous detectors ANODE STRIP CATHODE STRIPS Wire chamber: 1/R amplification field MSGC: dipole amplification field Very high field at cathode edge F. Sauli, Nucl. Instr. and Methods A386(1997)531 GEM: amplification field across ~ 25 µm (high at the edges of the hole) Anode NOT close to avalanche A.Oed, Nucl. Instr. and Meth. A263(1988)351 Micromegas: homogeneous amplification field across 50 µm Y. Giomataris et al, Nucl. Instr. and Meth. A376(1996)239 50 µm

Obtained so far for GEM and Micromegas M. Alfonsi et al, Nucl. Instr. and Meth. A518(2004)106 Micromegas (Nikhef measurement)

Dependence on detector technology Polymerisation will be mainly at the end of the avalanche where the electron density is highest A few µm away from the anode Exception: GEM Key issue Whta is the field at the anode surface? High field => high avalanche temperature => more dissociation organic molecules => more sensitive to ageing How big is the anode surface near avalanche? MSGC: very small (edge of anode strip) Wire chamber: quite small Micromegas: large GEM: avalanche not in vicinity of anode => GEM and Micromegas less vulnerable for ageing MSGC ageing: In the µC/cm range

Result At accumulated charge 2.8 mC/cm (peak value) Gas flow 2nd scan /1st scan At accumulated charge 2.8 mC/cm (peak value) Strong unexpected ageing effect No ageing downstream At prototype tests no ageing observed Until 3 C/cm Accumulated 3 C/cm in 120 days No effects seen

Design recommendations Reduce field on cathode surface as much as possible Use the cleanest materials you can afford (NASA and CERN database) But there’s no need getting bankrupt Add filter at the in coming gas close to the detector (molecular sieve 5A) Consider adding special ageing chamber for advance cleaning (see LHCB experience) But don’t expect this to be absolutely safe to prevent ageing Do as much ageing prototype tests as you can on as much different conditions to get an impression of the robustness of your detector Different particles Different irradiation rates Different sites

Operational recommendations While running, monitor the chamber performance on a daily basis and take immediate action when observing ageing phenomena Don’t change from gas supplier while running an experiment Be prepared to apply additives CF4 + oxygen containing molecule like CO2 or alcohols Water (active moisture control and monitoring), don’t let it pass the 1% limit => But be aware that these measures might worsen the situation in your specific case

some thoughts on charging-up effects HvdG, Nikhef RD51 Workshop, Paris, 2008

Micro Strip Gas Counters: hard to operate: discharges, ruining electrodes ageing ! Very strong electric field in insulator’s volume & surface !

GEM Production Remove copper by wet etching Irradiate CO2 laser Recent Status of Development GEM Production RIKEN/SciEnergy GEM (thick-foil and fine-pitch) pitch 80um hole 40um thickness 100um 100um 80um x750 Remove copper by wet etching Irradiate CO2 laser Remove remaining edge from the other side 22

Gain instability (RIKEN GEM) Recent Status of Development Gain instability (RIKEN GEM) No increase and decrease just after HV on. F. Simon (IEEE, 2006) T. Tamagawa(IEEE,2007) time (s) relative gain 3 hours No gain increase in short measurements This is not for a special batch of GEMs but for all GEMs we produced Possible reasons; Less charging-up due to cylindrical hole shape Less polarization of Liquid Crystal Polymer 23

GemGrid 1 GemGrid 2

conductivity of kapton Micromegas on pillars Edge discharge protection foil discharges + vibrations

Charge-up effects After (rapid) ramping of HV: polarisation: reduction of E-field in insulator (bulk) volume In homogeneous field with insulator // to field: nothing With E component perp. on insulating surface: modification of potential by hitting e- and/or ions until E // surface

GEM hole

equalizing with water Stronger effects for good insulator region of worse insulation

Very preliminary: Use as little as possible insulating surfaces // strong E fields Even more preliminary: As for gain: GEMs perform les than (corresponding) Micromegas

2nd RD51 Collaboration Meeting Plans for MPGD Radiation hardness tests for full detectors and components Matteo Alfonsi,Gabriele Croci, Elena Rocco, Serge Duarte Pinto, Leszek Ropelewski CERN GDD Group 2nd RD51 Collaboration Meeting Paris 13-15 October 2008 Working Group 2

Outline Full Detector Tests Components Tests Standard Triple GEM Bulk MicroMegas THGEM Components Tests Standard Triple GEM components Electrical Tests Mechanical Tests Gabriele Croci (CERN) - Radiation Hardness Tests – 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 32

Method followed for Full Detectors Make a series of measurement before putting this detector in beam of 60Co photons We would like to know if the performance of the detector is changed after strong irradiation (Total integrated dose of 106-107 Gy) Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 33

List of measurements Gain Rate Capability Discharge Probability Time Charging up Scan Type 1: Power on the detector and start to irradiate at the same time Time Charging up Scan Type 2: Power on the detector before starting the irradiation 2D Test (for Triple GEM) Test of uniformity over active area Counting plateau Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 34

What might happen after strong irradiation.. Gain  For TGEM, if the kapton resistivity is changed we can have less gain than before at the same voltage; it may happen that this variation may only be on the irradiated spots. Gain variation with time  The detector can have different charging up proprerties ..... 35

The Triple GEM Detector used Cartesian 2D X-Y Readout 10 x 10 cm2 Active Area Gas Mixture used Ar/C02 70%/30% C. Altumbas et al, NIM A490(2002)177 Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 36

Measurements performed so far (before irradiation) Cu X-Rays PH Spectrum Cu X-Rays ΔEFWHM/E = 18.8% Gain Cu X-Rays 55Fe X-Rays Plateau starts at HV=3700V Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 37

Radiation Hardness tests of Triple GEM detector components Materials to be tested: GEM Polyimide (Apical AV Kaneka) Glue (Araldite AY103) + Hardener (HY951) Frames Material (Permaglas) Tests to be performed Electric Test Measure kapton resistivity before and after gammas irradiation Mechanical Tests: make mechanical tests on components that represent crucial part of detector assembly Shear Test Peeling Test Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 38

We found a very old paper on kapton irradiation… R.G. Filho et al, “Induced conductivity Of Mylar and Kapton Irradiated by X-Rays”, IEEE Transactions on Electrical Insulation Volume EI-21 No. 3, June 1986 Kapton Samples of 80 mm diameter with thickness varying from 6 to 75 μm were irradiated with W X-Rays for several hours; They saw a variation of the Kapton conductivity Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 39

First Lab Irradiation Test (prelim. results) Measurement of Induced Conductivity inside a copper-clad 50 µm thick kapton foil (GEM w/o holes) This copper-clad kapton foil was powered with 500 V and irradiated at very high rate in open air with Cu X-Rays to understand if irradiation will vary its conducibility. Since measurement was performed in open air, air ionisation could be a problem. The current flowing from the top to the bottom electrode was monitored during irradiation Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 40

Measurement of Induced Conductivity inside a copper-clad kapton foil (GEM w/o holes) Literature K thickness 25 um E = 8 x 104 V/cm W X-Rays Conductivity * 10-16 (Ω-1 cm-1) Considering current we found a slope  0.3 pA/hour HV OFF, X-RAYS OFF Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 41 HV ON, X-RAYS OFF HV ON, X-RAYS ON

Shear Test Samples SIDE VIEW 50 mm AY 103 + HY951 50 µm thick Kapton Permaglas (Frames Material) AY 103 + HY951 50 mm 2 mm SIDE VIEW 20 mm TOP VIEW Pull Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 42

Peeling Test Samples SIDE VIEW AY 103 + HY951 Pull 120 mm Permaglas (Frames Material) 50 µm thick Kapton Pull 60 mm SIDE VIEW Sample width = 20 mm 2 mm Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 43

Previous studies on Araldite AY103 +HY951 !!! Studies made at CERN some years ago on the same glue used in Triple GEM detectors assembly Compilation of radiation damage test data, 4. / Guarino, Francesco et al. CERN-2001-006. - Geneva : CERN, 2001. - 131 p. Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 44

Is anybody interested in irradiating other detectors or components ??? Present Situation We are performing the tests before irradiation but now we need to find a 60Co irradiation facility!!!!! ANY SUGGESTIONS????? Is anybody interested in irradiating other detectors or components ??? Gabriele Croci (CERN) - Radiation Hardness Tests - 2nd RD51 Collaboration Meeting - Paris 13-15 October 2008 45

M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, 13-15 October 2008 Digital primary electron counting: W, Fano Factor, Polya vs Exponential M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, 13-15 October 2008

55Fe quanta conversions seen by GridPix 55Fe X-ray E0 5.9 and 6.5 keV Photo-e- TimePix chip Auger-e- After large drift distance, primary e- separate and can be counted InGrid Gas mixture: Ar/iso 95/5

55Fe quanta conversions seen by GridPix 55Fe X-ray E0 5.9 and 6.5 keV Photo-e- TimePix chip Auger-e- Photo-peak (photo-e and Auger-e) Escape peak (only photo-e) 2 conversions 3 conversions Raw spectrum Look at the escape peak only (smallest number of primary electrons)

Measurements of W and F 55Fe X-ray E0 5.9 and 6.5 keV Photo-e- TimePix chip Auger-e- What is measured is the mean and variance of the number of detected electrons (Nd, Vd) Correction for limited collection and detection efficiencies yield Np and Vp W = E0 / Np F = Vp / Np Collection and detection eff. should be known Np , Vp Nc , Vc Nd , Vd

Detection efficiency κ = ∫t∞ p(g).dg pixel threshold κ = ∫t∞ p(g).dg Exponential fluctuations: κ(g) = exp (-t/<g>) Polya-like fluctuations: parameter m=1/b ~ 2 with √b the relative rms κ(2,g) = (1+2.t/<g>) . exp(-2.t/<g>) Detection efficiency will be determined by fitting κ(g) to (Nd,Vgrid) data points

Detectors Two measurement periods Chamber geometry: 10 cm field cage 40 μm hole diameter Two measurement periods Timepix chip # 1: Standard InGrid Low event statistics Timepix chip #2 : Increased event statistics New GEMGrid structure Filter out 6.5 keV with Cr foil 30 μm hole diameter Chamber geometry: 10 cm field cage Guard electrode surrounding the chip (inside chamber)

Measured spectra at -330 V Timepix #1 Timepix #2 5.9 and 6.5 keV escape events (event ratio ~ 7:1) 5.9 and 6.5 keV escape events (event ratio ~ 50:1)

Peak position and grid voltage Asymptotic value of Nd gives the number of collected electrons Nc Polya fit works very well where exponential one (not shown) fails! Nc = 115 e- Nc = 102 e- Compatible with the smaller hole diameter of InGrid #2 Contribution from collection efficiency to peak width now known

Extrapolation to 5.9 keV photo-peak straightforward W and F in Ar/iso 95/5 at 2.9 keV Assume full collection efficiency of detector #1 Np = Nc = 115 ± 2 e- Extrapolation to 5.9 keV photo-peak straightforward Np = 230 ± 4 e- W = 25.2 ± 0.5 eV Peak width measured with detector #2 corrected for detection and collection eff. (87 %) RMS(Np) ~ 4.3 % Compatible with literature W = 25.0 ± 0.6 eV F = 0.250 ± 0.010 Ar/iso 20/80 – 1253 eV X-rays from Pansky. et al. J. Appl. Phys. 79 (1996) 8892 F = 0.21 ± 0.06

Scintillation Readout From THGEMs operating in xenon Joaquim M.F. dos Santos University of Coimbra; University of Aveiro Weizmann Institute of Sciences Universidad Autónoma de Barcelona/ Universidad Politécnica de Valencia 2nd RD51 collaboration meeting 13-15 Oct. 2008, Paris 57

Recent Relevant Applications of Optical TPCs Double Beta decay Experiments NEXT – Neutrino Xenon TPC Dark Matter search XENON, LUX, ZEPELIN, WARP experiments Secondary scintillation amplification, for higher sensitivity, with PMT/LAAPD readout Double mesh, uniform field scintillation gap e.g. secondary scintillation yield of 466 photons/e-/cm @ 4.1 kV/cm/bar (C.M.B. Monteiro et al., J. Inst. 2 P05001) Scintillation in hole-type microstructures, e.g. THGEMs RD51 Paris Oct. 2008 58 58

MPGD scintillation vs. charge readout A.S. Conceição, et al., J. Inst. 2 P09010 RD51 Paris Oct. 2008 59 59

GEM scintillation vs. charge readout LAAPD gain ~130 - 150 RD51 Paris Oct. 2008 60 60

THGEM scintillation vs. charge readout LAAPD gain ~130 - 150 RD51 Paris Oct. 2008 61 61

THGEM scintillation – Energy Resolution 30 keV 6% @ 2.5 bar RD51 Paris Oct. 2008 62 62

Scintillation and charge pulses correlation RD51 Paris Oct. 2008 63 63

Scintillation and charge correlated spectra RD51 Paris Oct. 2008 64

Scintillation and charge corrected spectra RD51 Paris Oct. 2008 65 65