Part 1 - Internal Resistance Part 2 - Cell Discharge Performance

Slides:



Advertisements
Similar presentations
© Philadelphia Scientific 2003 Philadelphia Scientific Advances in the Design and Application of Catalysts for VRLA Batteries Harold A. Vanasse – Philadelphia.
Advertisements

© Philadelphia Scientific 2002 Philadelphia Scientific Catalysts in Canada: The Science Behind 2 Years of Canadian VRLA Cell Rehydration and Catalyst Addition.
Battery-Informer TM Mega-Power The Battery-Informer TM A Battery Sale State of Health Indicator (SOH)
1 The Short Story on Long Cycles Why the length of your steam sterilization cycle may effect your sterility assurance.
Maintenance & Safety of Stationary Lead Acid Batteries
EET Electronics Survey Chapter 17 - Batteries.
ELECTRICAL I LESSON 2 BATTERY SERVICE
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
© Philadelphia Scientific 2006 Monobloc Batteries: High Temperatures, Life and Catalysts Harold A. Vanasse Daniel Jones Philadelphia Scientific.
VRLA Battery Maintenance and Safety UTC Region 3 Meeting October 4, 2012.
Developed by Bryce Rumery, K1GAX Maine ARES Section Emergency Coordinator 12 VDC Distribution Maine ARES.
Smart battery technology for a global environment Louie Lane #104 Reno, Nevada
1. 2 Executive Team Over 50 Years service to industry History of Service, Support, Solution and Satisfaction Dynamic Team Active in Industry Consortiums.
Federal Aviation Administration 0 Intermixing of Cells in Nickel-Cadmium Batteries for Aircraft Usage May 11, Intermixing of Cells in Nickel-Cadmium.
Who is Alber? Established 1972 Based in Boca Raton Florida We manufacture battery test equipment based on extensive experience in and knowledge about Battery.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Automotive Batteries Chapter 29.
BATTERY.
© Philadelphia Scientific 2004 A Case Study: Four Years of Performance Data at a Canadian Rehydration and Catalyst Addition Site Harold A. Vanasse – Philadelphia.
Current Electricity Electric Current Circuit – continuous conducting path between terminals of a battery (or other source of EMF) Electric Current.
UPS Battery Battery Sizing
REPLUS BATTERY REGEN Technical sales support: electrical products Lode Baert.
ML Series Product Presentation Product Management May 2004.
Automotive Electricity and Electronics, 3/e By James D. Halderman Copyright © 2011, 2009, 2005 Pearson Education, Inc., Upper Saddle River, NJ All.
ENERGY INSTITUTE Battery Research Group NiMH Battery Pack for HEV Cem Kaypmaz 2008 İstanbul.
Batteries The purpose of the battery is to act as a reservoir for storing electricity.
© 2011 Pearson Education, Inc. All Rights Reserved Automotive Technology, Fifth Edition James Halderman BATTERIES 50.
Check Point Renew Cell Prime Remarks Pulse Hz ~ 10,000 Hz * 40 kHzBy FET Charging Method Constant Current, 3 steps* 1 stepAccording to charging curve Pulse.
Battery Research and Testing, Inc.
VRLA BATTERIES-FAILURE MODES Sulphation: Negative Plates Corrosion: (a) Negative top- lead corrosion (b) Positive Grid Corrosion Dry-Out/Water-Loss Thermal.
THE PERFECT LIFTGATE BATTERY CHARGING SYSTEM FOR RYDER
CELLS IN SERIES AND PARALLEL Lesson 9. Cells in Series  The electric potential given to a single electron by a dry cell has an average voltage of around.
The Series Circuit Summary 1. The sum of the _____________or voltage equals the potential rise of the source. 2. The current is ______________ everywhere.
Technical Panel Session. Sunday January 11, DC System Failure Modes IEEE PES SBC Winter Meeting. January 11 – 15, New Orleans, LA Part 3.
Prof. Nikolay T. Tchamov Korkeakoulunkatu-1, TH – Tampere, Finland Tampere University of Technology RFIC Laboratory, Department of Electronics.
Practical Testing Issues Real Life Issues Bob Beavers June 12,
John Polenz Emerson Network Power Liebert Services.
Charging VRLA Batteries
Ch 19 Current and Potential Difference
Battery Monitoring Why – What - How DIEBOLD POWER SOLUTIONS LLC.
Electric Cells Section 5.3 (p. 217 – 226).
Battery Monitor Data Manager Demonstration
50 BATTERIES BATTERIES.
Inspection and test data analysis
Technology that lets you Trust your batteries!
IEEE PES SBC Winter Meeting. January 11 – 15, New Orleans, LA
Energy Storage & Stationary Battery Committee
BATTERY.
Non-ideal Power Supply
Lithium Operating Issues in a Stationary Environment
Battery 101.
Leader in testing and maintenance of reserve power
Baselining PMU Data to Find Patterns and Anomalies
Meeting Overview Slides
Lead acid batteries 12 V 24 V 48 V
Series and Parallel Circuits
Lithium Ion Battery Safety
Sealed lead grid technologies
Series Circuit.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Advances in the Design and Application of Catalysts for VRLA Batteries
Philadelphia Scientific
SAE battery safety standards committee UPDATE January 23, 2019
Modern Automotive Technology PowerPoint for by Russell Krick
abacus4u & AbacusIEEE Sample calculation
Battery Testing & Service
Telecom Battery Maintenance vs IEEE
UPS Application Alcad: UPS Application.
FIGURE 17–2 A grid from a battery used in both positive and negative plates.
Presentation transcript:

Part 1 - Internal Resistance Part 2 - Cell Discharge Performance Data Interpretation Part 1 - Internal Resistance Part 2 - Cell Discharge Performance Rick Tressler ESSB Technical Symposium Monday June 11, 2017 Chattanooga, TN

Part 1 - Internal Resistance

Internal Resistance Problems in Data Center UPS Typical system - 40, 12V VRLA X 4 strings Multiple systems all in data center UPS application Cabinet enclosures Good operating environment – 72-75°F Trained technicians Consistent testing methods

Average Internal Resistance Over Service Life (Micro-Ohms) 5/10/2014 3979 Max 20% 3840 Installation 8/16/11 3580 1/7/2014 Warning 15% 3486 Baseline Established 3/6/2012 3032 11/17/11 Baseline

Float Voltage History – Non-Temperature Compensated Manufacturer Recommended Float – 13.50 – 13.8 Volts (2.25 – 2.30 VPC) Overall Float Voltage Range - 540-552 Volts

Part 1 Summary Problems spanned across many systems in the facility All systems were of same vintage of manufacture There was no root cause result provided, post replacement Different manufacturer was used for replacement systems

Part 2 - Cell Discharge Performance

Performance Test Results in a Controls UPS Modular installation 3 years old 60, 2V VRLA x 1 string, 105 AH (8hr capacity) No testing or previous maintenance - no operating history Industrial controls UPS application Good operating environment – 75-80°F Tested at published 2 hour rate to 1.78 VPC Test was paused once to bypass 3 cells, resulting in exceeding 6 minute recommendation in IEEE 1188

Typical cell behavior during discharge This dip in cell voltage observed immediately after starting a test, followed by a recovery is normal for lead-acid batteries. Known as Coup de Fouet. Recovery during a pause in the test. Typical cell behavior during discharge

Abnormal cell behavior on discharge. Cell failed just over 1 hour into a 2 hour test. This cell was bypassed. 29% capacity Possible Internal Issue: Metallurgical problem with grids, straps, posts internal to the cell. Characterized by an immediate and sustained drop in cell voltage during discharge. Abnormally high cell resistance was observed pre-test. 00:35:00 min

40% capacity Abnormal cell behavior on discharge. Cell just under 50 minutes into a 2 hour test. This cell was bypassed so the test could continue. 40% capacity Possible Internal Issue: Premature dry-out. No indication of high internal resistance. Characterized by a sharp drop in cell voltage during the discharge. Abnormally high cell resistance was not observed pre-test.

Overall battery performance showing battery voltage and load current Overall battery performance showing battery voltage and load current. Three cells failed. Overall capacity was 90% with 3 cells bypassed. Overall capacity 89.5%

Part 2 Summary Maintenance should have been started sooner than 3 years into life Actual capacity when new is questionable The above is an excellent rationale to perform an acceptance test Ohmic measurements don’t always foretell of cell problems Unexpected cell behavior can indicate problems but require a post mortem internal inspection to confirm a specific cause

Part 1 - Internal Resistance Part 2 - Cell Discharge Performance Data Interpretation Part 1 - Internal Resistance Part 2 - Cell Discharge Performance Rick Tressler ESSB Technical Symposium Monday June 11, 2017 Chattanooga, TN