EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR

Slides:



Advertisements
Similar presentations
Digital Current Transformer Reporter
Advertisements

Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Technical Conference - Panama City Beach, Fl Flame Rectification l Remember Ohm’s Law E = I X R.
Electrical Safety 29 CFR I. Background for the Trainer:
Understanding GFCIs Developed by NEMA Ground Fault Personnel Protection Section (5PP) Developed by NEMA Ground Fault Personnel Protection Section (5PP)
Furnace Troubleshooting
Using a Multimeter.
Troubleshooting Aircraft Charging Systems ( Alternators/Reciprocating Engines) by Herb Spenner.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
The Association of Electrical and Medical Imaging Equipment Manufacturers Understanding GFCIs Developed by the NEMA 5PP Personnel Protection Technical.
G GE Power Management MMII Intelligent MCC Controller.
Basic Electricity.
Electrical Safety Testing of Electrical Installations and the verification of Electricians Test Tools Michael Bailey Transmille Ltd NCSLi 2014Transmille.
3200A Options / Technical Overview. 3200A Electrical Test Calibrator Innovative design to bring advances in technology to the calibration of Electrical.
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
INSULATION TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
System Sentry Protect and Defend Your ATR. 1.Help’s prevent sites from going down. 2.If site should fail, provides the tools to remotely restart and repair.
Prof. D. Wilton ECE Dept. Notes 5 ECE 2317 Applied Electricity and Magnetism Notes prepared by the EM group, University of Houston.
3200 Electrical Test Equipment Calibrator The Total Solution to Electrical Test Equipment Calibration.
PORTABLE & TRANSPORTABLE ELECTRICAL EQUIPMENT. Legal Requirement and References Abu Dhabi RSB Electrical Regulations - makes reference to the need to.
© 2007 Ideal Industries 1 of 12 Basics Clamp-on Ground Resistance Tester.
PR570 POWERITE II TRAINING Dedicated to Success in Electronic Servicing for 50 Years.
1 of 25 © 2007 Ideal Industries Power Quality At the Plug IDEAL INDUSTRIES Author: Patrick Elliott Application Guide to Power Quality.
PAT TESTER CALIBRATION Using the 3200 Electrical Test Calibrator.
Main contacts closed – RED Colour with ON
Atlanta IAS Presentation November 2015 Presentation by: Hilton Mills Hood-Patterson & Dewar 850 Center Way, Norcross GA
Page 1 LXMG PanelMatch™, StayLit™ Dual Lamp CCFL Inverter Module Training Kit Rev 1.1 November 2006
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
Electromechanical Relays Mechatronics ECE 5320 Assignment #1 Paul Smart.
Using a Multimeter.
Electrical Safety.
PROBLEM OF SPILL CURRENT WITH RESIDUALLY CONNECTED
Electrical Engineering for Physicists How to get from the 208 VAC 3-phase power in the building to 110- and 220-VAC Code issues All work must be done in.
PROTECTION AGAINST INDIRECT CONTACT
Technical Specification
DVOM Not-So Basics.
THREE PHASE FAULT ANALYSIS WITH AUTO RESET ON TEMPORARY FAULT AND PERMANENT TRIP OTHERWISE Submitted by:
Basic Electrical Safety
Intelligent controller with Microprocessor Incorporated NPS6220
TPS - Thyristor Power Supply for Resistive/Inductive Loads
Electrical Heat Tracing Control & Monitoring Basics
Relay operation Water level Indicator
GROUND-FAULT GROUND-CHECK MONITOR
GROUND FAULT & EARTH LEAKAGE MONITORS
FEEDER PROTECTION UNIT
MPU-16A MOTOR PROTECTION UNIT.
MPU-16A / FPU-16 TEST UNIT TUTORIAL
NEUTRAL-GROUNDING-RESISTOR MONITOR
Using the DMM.
HVI HIPOT TEST SET Pft sERIES.
Associated Hazards and Safety Practices
Electrical Safety in the Home
Chapter Six Ground-Fault Circuit Interrupters, Arc-Fault Circuit Interrupters, Surge Protective Devices, Immersion Detection Circuit Interrupters, and.
CSCI1600: Embedded and Real Time Software
Electric Current.
Chapter 4 – Ohm’s Law, Power and Energy
What Is to Be Covered? Electrical Shock - Why Have GFCIs?
Basic Electrical Safety
CSCI1600: Embedded and Real Time Software
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Basic Electrical Safety
DCM305E Earth Leakage Clamp Meter
Basic Electric Principles
Electrical components and systems
easYgen-3000XT Series Training
Difference between Earthing & Grounding
Earth Leakage Protection
Presentation transcript:

EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR SE-525 EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR

WHY MONITOR THE GROUND INTEGRITY? PORTABLE EQUIPMENT + V- LOW GROUND RESISTANCE = LOW VOLTAGE BETWEEN EQUIPMENT AND GROUND DURING A FAULT FAULT CURRENT GROUND CONDUCTOR PORTABLE EQUIPMENT BROKEN GROUND CONDUCTOR FAULT CURRENT HIGH GROUND RESISTANCE = HAZARDOUS VOLTAGE BETWEEN EQUIPMENT AND GROUND DURING A FAULT + V-

EARTH-LEAKAGE AND GROUND-INTEGRITY MONITOR The SE-525 is a microprocessor-based earth-leakage and ground-integrity monitor for welding applications. The SE-525 will detect one ohm of ground resistance and as low as 10 mA of ground-fault current.

SE-525 FEATURES LED and fluorescent-flag trip indication for both earth-fault and ground-integrity fault. Autoreset or Latching trips. Local and remote reset. Form C Trip relay. Two form C Indication relays. 4-20 mA analog output. Harmonic filtering (DFT) CT verification. Earth-fault test using CT-primary injection. One-ohm ground integrity test. Conformal coating for corrosion resistance.

GROUND-INTEGRITY TRIP SE-525 0PERATION POWER INDICATION GROUND-INTEGRITY TRIP TRIP RELAY ENERGIZED EARTH-LEAKAGE TRIP RESET 10 150 200 300 400 500 100 80 60 30 GF LEVEL (mA) 30 400 500 600 800 1000 300 200 100 55 GF TIME (ms) FIXED FREQENCY 1 2 3 4 5 NON-FAIL-SAFE CT VERIFY ON AUTO RESET VARIABLE FREQ. CT VERIFY OFF FAIL-SAFE LATCHING

SE-525 TYPICAL APPLICATION SPOT WELDER GROUND CONDUCTOR GROUND INTEGRITY TEST SENSE LEAD M SE-CS30-X GROUND FAULT TEST REMOTE RESET SPOT 1 Ω GROUND TEST 22 24 21 23 Alternate two-wire ground integrity connection used when the resistance of the sense lead is in the one-ohm range. 4-20 mA OUTPUT GROUND-FAULT INDICATION RELAYS N.O. & N.C. GROUND INTEGRITY INDICATION RELAYS N.O. & N.C. L1 120 VAC N M

SE-525 TYPICAL APPLICATION GROUND FAULT POWER GROUND INTEGRITY RESET TO WELDER