Horizontal Tests in a Vertical Cryostat

Slides:



Advertisements
Similar presentations
Superconducting Spoke Resonator Cavities and Cryomodules
Advertisements

Progress and Plan for Superconducting RF Cavity RF Group.
SRF Cryomodule Assembly Facility Plans Tug Arkan AAC, May 10-12, 2005.
February 17-18, 2010 R&D ERL Roberto Than R&D ERL Cryogenics Roberto Than February 17-18, 2010 CRYOGENICS.
An SRF Single Cavity Horizontal Test Facility Tom Peterson, Fermilab May 10, 2005.
23 Jan 2007 LASA Cryogenics Global Group 1 ILC Cryomodule piping L. Tavian for the cryogenics global group.
April, 2009 ERL SRF CRYO MODULES AND CRYOGENIC SYSTEM.
IHEP 1.3 GHz Cryomodule and Cryogenics IHEP Cryogenic group 2nd Workshop of the IHEP 1.3 GHz SRF R&D Project Dec 2 nd, 2009.
Arnaud Vande Craen (TE-MSC) 27/02/20131 EUCARD : ESAC Review – CEA Saclay.
CEC/ICMC 2015, Tucson Anatoly Zhirnov, DESY presented by Anatoly Zhirnov, DESY, MKS With a huge appreciation to colleagues from INP-PAS (Poland), WUT (Poland),
Safety Requirements and Regulations 10/3/20121Safety Requirements & Regulations James Sears.
Accelerator/WP High Beta Structures Alan Wheelhouse HIGH-BETA CAVITY DELIVERY April 21, 2015.
WP : HIGH-BETA CAVITY DELIVERY A Wheelhouse ASTeC, STFC Daresbury Laboratory ESS SRF Elliptical Cavities Kick-Off Meeting CEA Saclay 15 th December.
HIGH-BETA CAVITY DELIVERY P McIntosh ASTeC, STFC Daresbury Laboratory ESS Technical Advisory Committee Lund 1 – 2 April 2015.
Project X RD&D Plan Cryogenics Arkadiy Klebaner AAC Meeting February 3, 2009.
Accelerator/ Medium Beta Cavities Paolo Michelato INFN Milano - LASA April 21, 2015.
Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC 1 Horizontal Tests in a Vertical Cryostat Shrikant Pattalwar STFC Daresbury Laboratory UK.
Medium Beta Cavities Paolo Michelato, Paolo Pierini, and Carlo Pagani INFN Milano - LASA.
Medium beta cavities Paolo Michelato, Paolo Pierini, Carlo Pagani INFN Milano - LASA.
Process Definition of the Operation Modes for Super-FRS Magnet Testing CSCY - CrYogenic department in Common System, GSI, Darmstadt Y. Xiang, F. Wamers.
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
MAGNET#1MAGNET#2MAGNET#3 SATELLITE VB#1 SATELLITE VB#2 SATELLITE VB#3 PRECOOLER#1PRECOOLER#2 DISTRIBUTION VALVE BOX DVB CP#1CP#3CP#2 BUFFER DEWAR LHe 5m.
JLAB Pressure Systems Considerations Ed Daly. Outline Introduction Federal Law - 10CFR851 Compliance JLAB Pressure Systems Program –Complies with 10CFR851,
Shrikant_Pattalwar ICEC 26, March 7-11, 2016, Delhi 1 Horizontal Tests in a Vertical Cryostat Shrikant Pattalwar STFC Daresbury Laboratory UK.
Vacuum experiences on XFEL Beam Position Quadrupole Units (BQU) preparation Marco Schalwat TTC Topical Workshop on SRF Cryomodule Clean Room Assembly CEA.
Integration and Cold Testing of the CW ERL Cryomodule at Daresbury Shrikant Pattalwar ASTeC, STFC, Daresbury Laboratory (UK) On behalf of ERL Cryomodule.
WP : HIGH-BETA CAVITY DELIVERY A Wheelhouse ASTeC, STFC Daresbury Laboratory ESS SRF Elliptical Cavities Kick-Off Meeting CEA Saclay 23 rd June 2015.
Overview of the ESS Linac Cryogenic Distribution System
Cryogenics for SuperB IR Magnets J. G. Weisend II SLAC National Accelerator Lab.
S. Barbanotti - DESY Requirements Conformance for SRF Cryomodules Workshop 16/10/2014 – ESS, Lund XFEL cryostat main components: Quality Assurance and.
Spoke section of the ESS linac: - the Spoke cryomodules - the cryogenic distribution system P. DUTHIL (CNRS-IN2P3 IPN Orsay / Division Accélérateurs) on.
CRYOGENIC SYSTEM of RAON Chul Jin Choi, Ki Woong Lee Cryogenics and Control Team Accelerator Division 5/23/2013 Chul Jin Choi, Ki Woong Lee Cryogenics.
Development of Cryo-Module Test Stand (CMTS) for Fermi Lab (R.L.Suthar, Head,CDM, BARC) Cryo-Module Test stand (CMTS) is a very sophisticated equipment.
Developing the Collaboration P McIntosh STFC Daresbury Laboratory.
WP : High-Beta Cavity Delivery
ESS Cryomodule Status Meeting – Introduction | | Christine Darve Introduction to Cryomodules for the ESS 2013 January, 9 th Christine Darve.
ESS | Helium Distribution | | Torsten Koettig Linac – Helium distribution 1.
October 7, 2010 HINS Test Cryostat 2 K Conversion Status October 7, 2010.
Recent Result for the STF-2 Cryomodule Operation
WP High Beta Cavities Delivery
Final Design Cryogenic and mechanical configurations
LCLS-II Technical Requirements
Serial testing of XFEL cryomodules: results of the cryogenic heat load measurements  T Böckmann1, Y Bozhko1, W Gay2, P Halczynski2, B Petersen1, S Putselyk3,
High-Beta cavity STATUS at DAREsbury laboratory
FRIB Cryogenic Support
at STFC Daresbury laboratory
Cryogenic behavior of the cryogenic system
Mark Pendleton – STFC Daresbury Laboratory
Proximity Cryogenics P&IDs meeting
TTC Topical Workshop - CW SRF, Cornell 12th – 14th June 2013
SPS cryogenic proximity equipment and SM18 validation
LARP Vertical Test Facility
Hongyu Bai LCLS-II 2 K Cold Box FDR March 9, 2017
Small Coolers for MICE MICE Collaboration Meeting RAL Michael A. Green
Introduction to W7-X Coil Testing at CEA – Saclay, France
CEPC Cryogenic System Jianqin Zhang, Shaopeng Li
Accelerator Module Test Facility
Commissioning and First Cooldown of XFEL Linac
UK RFD Pre-Series cryomodule
Operation experience of cryogenic system and cryomodules for the superconducting linear accelerator at IUAC, New Delhi. T S Datta ( On behalf of Cryogenics.
EU-XFEL summary of performance degradation
ILC Experimental Hall Cryogenics An Overview
ESS elliptical cryomodule
Presented by: Ruben Carcagno
Schematic diagram of the cryogenic system
Daresbury ESS In-Kind Contributions
CTF Users’ Perspective
Cryogenic behavior of the magnet
Burst Disc Experiences at CEA Test Stand
Overview of the TARGET Monolith Rough Vacuum
Presentation transcript:

Horizontal Tests in a Vertical Cryostat Shrikant Pattalwar STFC Daresbury Laboratory UK Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Outline Introduction Test Configuration Seek Comments / Suggestion Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

ESS UK contribution €184m Total Construction cost €1.84B Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC STFC ESS Delivery In February 2015 STFC requested to procure and test all high-β SRF elliptical cavities: Nb procurement Dressed cavity fabrication with industry Vertical tests Shipment to CEA Saclay for CM integration ~6m ~1.2m Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Testing rate of ~1 cavity/week 

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Dressed Cavity Total of 84 dressed 704 MHz cavities: Plus 4 possible spares. Operating specification: 20 MV/m @ Qo > 5 x 109 Testing specification: 23.9 MV/m @ Qo > 5 x 109 Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Filename_20150922_ESS_VTF

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Conventional Method Immerse the Object (Cavity) in liquid helium bath (Vertical Cryostat) Pump on the Liquid helium bath with either cold compressor or Vacuum Pump to reduce the bath pressure to 30 mbar ( 2 K) Use 2K heat exchanger + JT valve to maintain liquid helium level Testing XFEL cavities at DESY 3 2 1 CRYOGENICS OF EUROPEAN XFEL ACCELERATOR MODULE TEST FACILITY Bozhko Y., Petersen B., Schnautz T., Sellmann D., Wang X.L, Zhirnov A., Zolotov A., DESY Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Vertical Cryostat for High-b Cavities Requirements work out be: Usable LHe vessel diameter ~1.5 m (Diameter of a 704 MHz cavity ~ 0.5 m) Cryostat becomes sufficiently large to test cavities horizontally LHe bath volume ~3500 l LHe required per test ~7500 l Gas handling capacity ~20 g/S (2K Hex, 2K pump, distribution Pipes, Valves, safety devices , etc. ) Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Alternative Approach: Horizontal Tests in a Vertical Cryostat Test 3 cavities simultaneously. Each cavity already has its own helium vessel: Necessary and sufficient condition is to cool the cavity to 2K Can be easily achieved by filling liquid helium in its own vessel (with a volume of ~ only 50 l) Cryogenic Requirements: LHe per test reduces from: ~7500 l to ~1500 l (factor of 5!) Gas handling capacity reduces from: ~20 g/S to < 2 g/S (factor of 10!) Significantly simplified and lower cost ancillaries (2K Hex, 2K pump, distribution Pipes, Valves, safety devices , etc. ) Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Benefits Horizontal tests – Performance in near final configuration Automatic leak checks on helium vessel (Not possible in bath cryostat) More confidence in performance More than 75% saving on LHe Reduced test duration (quick cool-down/ warm up) Lower Operational Hazards (due to lower gas flow/less quantity of LHe) 75 % Saving on LHe and Gas Storage 20 g/S 2 g/S 10,000 l 2,000 l Risks / Issues Additional assembly steps Additional leak checks during assembly Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Test configurations/Pros & Cons Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Typical Test Scenario (excluding cavity Assembly) Test can continue for few extra days if required Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Cryogenic Schematic KEEP CLEAR Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC Summary Proposal to conduct tests in horizontal configuration in a vertical cryostat Major benefits are due to substantial reduction in LHe consumption And also due to reduction in mass flow, leading to reduction in size the 2K system Mounting of Cavities on the Insert becomes more complicated but can be managed by introducing additional QC processes. So far we do not see any show stoppers or many issues We welcome any comments / suggestions/ identification of any potential issues Thank You Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC

Shrikant_Pattalwar TTC 2015 Dec 1, 2015 SLAC