Outcome 4 Mechanical central heating controls Unit 208: Central heating systems.

Slides:



Advertisements
Similar presentations
Laddomat 21 For accumulation when using a wood-fired boiler Picture 1
Advertisements

Central Heating (Pipework Only). Forced circulation through loop pipework only Central Heating – One pipe system Central Heating – Types of systems (Part.
ADX 150 – Engine Repair ADX 170 – Climate Controls
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Permanent Head Gasket & Block Repair w/Nanotechnology, 32 Fl Oz
Engine Overheating.
Unit 206: Domestic hot water systems
Unit 206: Domestic hot water systems
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
Objective of the session.
Cooling As working temperatures rise, the strength of metals used reduces. This in turn will force manufacturers to use superior metals/alloys, which can.
11-1 Copyright  2010 McGraw-Hill Australia Pty Ltd PowerPoint slides to accompany Puffett, Hossack, Stone, Burn & Miles, Gasfitting 2e Chapter 11 OPERATION.
Unit 206: Domestic hot water systems
Filling, purging and air removal
Chapter 6 Thermal Energy
CCAS 3381 AUTOMOTIVE SKILL I ENGINE SUBSYSTEMS. OBJECTIVES To understand the operational principles and basic mechanisms of engine sub-systems Lecture.
Engine Systems and Components
Unit 208: Central heating systems
Outcome 2 Materials used to install domestic central heating pipework Unit 208: Central heating systems.
Unit 206: Domestic hot water systems
Unit 205: Cold water systems
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Unit 206: Domestic hot water systems
Presentation on Installation of a Domestic Cold Water Storage Cistern
STEAM HEATING.
Hydronic Mechanical Controls
PLUMBING Presentation on Central Heating. Forced circulation through loop pipework only Central Heating – Types of systems (Part 1) - One pipe system.
Screened Warning Pipe A screened water pipe is a requirement under the water regulations. The pipe should be one size larger that the supply pipe.
Outcome 3 (part 2) Heat emitters and their components Unit 208: Central heating systems.
HVAC523 Circulator Pumps.
HVAC523 Basic Subsystems.
HYDRONIC HEATING AQUASTATS
Unit 208: Central heating systems
Air Conditioning Heating Refrigeration
Cooling Systems Purpose: to keep the engine at it’s most efficient operating temperature TOO HOT! TOO COLD! - poor lubrication - excessive heat - seizing.
PLUMBING Presentation on Central Heating – Pump Position.
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
Outcome 1 (part 2) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
Section 3 Using Heat.
The Cooling System.
OILGEAR PVV PUMPS PVV 200 Performance Curves.
The Cooling System (Reasons for)
HOT WATER Understand and apply domestic hot water system installation and maintenance techniques.
CIBSE HCNW 28 August 2014 Modular boilers. Traditional or low-tech replacement boiler installation; Multiple boilers eg 2 no 66% of load for security.
Boiler Energy Saver Advanced Boiler Controls. Most boiler controls at present consist of a switch!
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Maintenance of a Vehicle’s Cooling System. Regular maintenance of a vehicle's cooling system is important to keep the vehicle running properly and to.
Energy and Heat. What is Energy? When something is able to change its environment or itself, it has energy Energy is the ability to change Energy has.
Engine Cooling Systems
Machinery Auxiliary Systems
Automotive Heating And Air Conditioning
Unit 13 Oil-Burning Equipment
The Engine Cooling System
Pneumatic and Hydraulic
Section 3: Using Thermal Energy
Outcome 1 (part 1) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Hot water Systems Heaters.
5508BESG Services and Utilities Lecture 2
L 20 Thermodynamics [5] heat, work, and internal energy
Hot Water Systems Cylinders and Systems.
______________ Combustion Engine
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Cooling System.
Presentation transcript:

Outcome 4 Mechanical central heating controls Unit 208: Central heating systems

Controls Circulator The circulator is located in position by pump flanges – these either have rubber or fibre washers to maintain the watertight seal. The full bore valves either side of the flanges can be closed to allow the pump to be removed without draining the system.

Controls Circulator The correct positioning of the circulator in the system is of great importance to avoid corrosion by aeration of the system water: Pumping over Drawing air in If air is drawn into the system water, corrosion will take place.

Controls Circulator Inhibitor is added to the system water to reduce corrosion and the build-up of scale, and the level of inhibitor in the system should be tested on a regular basis. The neutral point of the system is at the base of the cold feed, where it joins the system. The pump must always draw on the cold feed. VENT COLD FEED PUMP

Controls Circulator VENT COLD FEED PUMP If this is correctly followed, the system water will be circulated under a positive pressure. If this is not followed, the system water could be circulated under a negative pressure, thus drawing in air, pumping over and creating corrosion.

Controls Circulator As the system requires positive pressure, the position of the circulator is important in relation to the cold feed and vent pipe.

Controls Circulator Air (oxygen) + water (system water) + iron (radiator) = Corrosion (rust) = Magnetite Magnetite will block components, restricting flow, and will also start to cause cool/cold areas on the radiators.

Controls Two port motorised valve Commonly know as a zone valve, this can be activated by a room or cylinder thermostat. This allows both hot water and the heating circuits to be controlled separately.

Controls Two port motorised valve When there is a call for heat, the zone valve opens and allows water from the boiler to circulate around the pipework. Likewise, when the thermostat is up to temperature, the zone valve is closed (isolates).

Controls Two port motorised valve With both the room thermostat and the cylinder thermostat satisfied, the zone valves will close. When the zone valves close, the boiler switches off and when the heat is dissipated from the heat exchanger, the circulator will switch off. This is known as boiler interlock. An electrical arrangement of controls ensures the boiler does not operate when there is no demand. This will avoid the boiler to cycle and so save fuel, reduce emissions and save on some wear and tear.

Controls Two port motorised valve The paddle in the zone valve is powered by a synchronmotor. As this rotates, it opens or closes the valve. This can be replaced if there is a fault, without releasing any system water. Safe isolation procedures will need to be followed.

Controls Three port mid-position valve This valve controls the flow of water to both the heating and hot water circuits. It reacts to both the cylinder and room thermostat but cannot completely stop the flow of water like the zone valve can: water is always able to flow. The three ports are labeled: AB = flow for the boiler A = central heating B = hot water

Controls Three port mid-position valve When at rest, the valve paddle sits in the hot water position, so always allows the flow of water. When there is a call for heat from the cylinder thermostat, the valve does not need to activate, as the system water can flow to the cylinder coil.

Controls Three port mid-position valve When there is a call for heat from the room thermostat, the valve activates and the paddle moves the A port across and blocks the B port. This allows the system water to flow around the central heating circuit.

Controls Three port mid-position valve When there is a call for heat from both the cylinder and room thermostat, the valve paddle moves to the mid- position, allowing system water to flow around both circuits.

Controls Three port diverter valve These valves are commonly found in combination boilers and some older systems (W plan). When at rest, the valve paddle sits in the hot water position, which allows the flow of water. This valve is unable to remain in the mid-position and can only divert the water flow to one or the other circuits. It is known as a W plan – water priority.

Controls Three port diverter valve When there is a call for heat from the cylinder thermostat (W plan) or a hot tap is opened (combination boiler), the valve does not need to activate, as the system water can flow to the cylinder coil or plate heat exchanger.

Controls Three port diverter valve When there is a call for heat from the room thermostat, the valve activates and the paddle moves from the A port and blocks the B port. This allows the system water to flow around the central heating circuit. If there is a demand for hot water at any point, the valve will revert back to its original position until that demand is satisfied.