Portable, robust optical Frequency standards in hollow optical fiber

Slides:



Advertisements
Similar presentations
Wavelength – Frequency Measurements
Advertisements

Constructing Gas Lasers Inside of Photonic Band Gap Fiber Optic Cells Joshua Perkins Texas A&M University Kansas State University REU Mentor- Dr. Kristan.
Optical sources Lecture 5.
CAVITY RING DOWN SPECTROSCOPY
Sub-Doppler Resolution Spectroscopy of the fundamental band of HCl with an Optical Frequency Comb ○ K. Iwakuni, M. Abe, and H. Sasada Department of Physics,
In Search of the “Absolute” Optical Phase
Tunable Laser Spectroscopy Referenced with Dual Frequency Combs International Symposium on Molecular Spectroscopy 2010 Fabrizio Giorgetta, Ian Coddington,
Results The optical frequencies of the D 1 and D 2 components were measured using a single FLFC component. Typical spectra are shown in the Figure below.
Chapter 8 Doppler-free laser spectroscopy. Contents 8.1 Doppler broadening of spectral lines 8.2 The crossed-beam method 8.3 Saturated absorption spectroscopy.
Dual-Comb Spectroscopy of C2H2, CH4 and H2O over 1.0 – 1.7 μm
Narrow transitions induced by broad band pulses  |g> |f> Loss of spectral resolution.
Absorption and emission processes
Hyperfine Studies of Lithium using Saturated Absorption Spectroscopy Tory Carr Advisor: Dr. Alex Cronin.
Microwave Spectroscopy I
Dispersion Measurements Lecture-3. Dispersion Measurements Measurement of Intermodal Dispersion The most common method for measuring multimode fiber bandwidth.
Lecture 3 INFRARED SPECTROMETRY
Designing High Power Single Frequency Fiber Lasers Dmitriy Churin Course OPTI
MID-IR SATURATION SPECTROSCOPY OF HeH + MOLECULAR ION HSUAN-CHEN CHEN,CHUNG-YUN HSIAO Institute of Photonics Technologies, National Tsing Hua University,
IR/THz Double Resonance Spectroscopy in the Pressure Broadened Regime: A Path Towards Atmospheric Gas Sensing Sree H. Srikantaiah Dane J. Phillips Frank.
Spectroscopy with comb-referenced diode lasers
Mikael Siltanen,1 Markus Metsälä,1
B.SC.II PAPER-B (OPTICS and LASERS)
Solution Due to the Doppler effect arising from the random motions of the gas atoms, the laser radiation from gas-lasers is broadened around a central.
High Precision Mid-Infrared Spectroscopy of 12 C 16 O 2 : Progress Report Speaker: Wei-Jo Ting Department of Physics National Tsing Hua University
Tunable Mid-IR Frequency Comb for Molecular Spectroscopy
Brian Siller, Andrew Mills, Michael Porambo & Benjamin McCall University of Illinois at Urbana-Champaign.
Brian Siller, Andrew Mills, Michael Porambo & Benjamin McCall Chemistry Department, University of Illinois at Urbana-Champaign.
Fukuoka Univ. A. Nishiyama, A. Matsuba, M. Misono Doppler-Free Two-Photon Absorption Spectroscopy of Naphthalene Assisted by an Optical Frequency Comb.
Tunable, resonant heterodyne interferometer for neutral hydrogen measurements in tokamak plasmas * J.J. Moschella, R.C. Hazelton, M.D. Keitz, and C.C.
Progress of the Laser Spectroscopy Program at Bridgewater State College Greg Surman, Brian Keith, and Edward Deveney Department of Physics, Bridgewater.
__–––– Sensitivity Scaling of Dual Frequency Combs Ian Coddington, Esther Baumann, Fabrizio Giorgetta, William Swann, Nate Newbury NIST, Boulder, CO
Broadband Mid-infrared Comb-Resolved Fourier Transform Spectroscopy Kevin F. Lee A. Mills, C. Mohr, Jie Jiang, Martin E. Fermann P. Masłowski.
HIGH PRECISION MID-IR SPECTROSCOPY OF N2O NEAR 4.5 μm Wei-jo (Vivian) Ting and Jow-Tsong Shy Department of Physics National Tsing Hua University Hsinchu,
Haifeng Huang and Kevin K. Lehmann
Precision Measurement of CO 2 Hotband Transition at 4.3  m Using a Hot Cell PEI-LING LUO, JYUN-YU TIAN, HSHAN-CHEN CHEN, Institute of Photonics Technologies,
Fiber-laser-based NICE-OHMS
Development of a System for High Resolution Spectroscopy with an Optical Frequency Comb Dept. of Applied Physics, Fukuoka Univ., JST PRESTO, M. MISONO,
Precision Laser Spectroscopy of H 3 + Hsuan-Chen Chen 1, Jin-Long Peng 2, Takayoshi Amano 3,4, Jow-Tsong Shy 1,5 1 Institute of Photonics Technologies,
CH 3 D Near Infrared Cavity Ring-down Spectrum Reanalysis and IR-IR Double Resonance S. Luna Yang George Y. Schwartz Kevin K. Lehmann University of Virginia.
Direct Comb Spectroscopy of Buffer-Gas Cooled Molecules Ben Spaun ISMS, 2015 JILA, NIST and University of Colorado at Boulder.
Tze-Wei Liu Y-C Hsu & Wang-Yau Cheng
OBSERVATION AND ANALYSIS OF THE A 1 -A 2 SPLITTING OF CH 3 D M. ABE*, H. Sera and H. SASADA Department of Physics, Faculty of Science and Technology, Keio.
A. Nishiyama a, K. Nakashima b, A. Matsuba b, and M. Misono b a The University of Electro-Communications b Fukuoka University High Resolution Spectroscopy.
Frequency-comb referenced spectroscopy of v 4 =1 and v 5 =1 hot bands in the 1. 5 µm spectrum of C 2 H 2 Trevor Sears Greg Hall Talk WF08, ISMS 2015 Matt.
Frequency combs – evolutionary tree Overview Frequency Metrology Measuring Frequency Gaps Frequency Combs as Optical Synthesizers Time Domain Applicatons.
Fiber Frequency Combs Jennifer Black EE230 Final Presentation.
High Precision Mid-IR Spectroscopy of 12 C 16 O 2 : ← Band Near 4.3 µm Jow-Tsong Shy Department of Physics, National Tsing Hua University,
Many-Body Effects in a Frozen Rydberg Gas Feng zhigang
1 Frekvenčni standard in merjenje z optičnim glavnikom.
Saturation Roi Levy. Motivation To show the deference between linear and non linear spectroscopy To understand how saturation spectroscopy is been applied.
Mingyun Li & Kevin Lehmann Department of Chemistry and Physics
Single and dual wavelength Er:Yb double clad fiber lasers
Multiplexed saturation spectroscopy with electro-optic frequency combs
Mid-Infrared fiber-based optical frequency synthesizer
M. Faheem, R. Thapa, and Kristan L. Corwin Kansas State University
Doppler-free two-photon absorption spectroscopy of vibronic excited states of naphthalene assisted by an optical frequency comb UNIV. of Electro-Communications.
The Near-IR Spectrum of CH3D
Fiber Laser Preamplifier
Really Basic Optics Instrument Sample Sample Prep Instrument Out put
69th. International Symposium on Molecular Spectroscopy
Two-Photon Absorption Spectroscopy of Rubidium
A.S. Ghalumyan, V.T. Nikoghosyan Yerevan Physics Institute, Armenia
Optoelectronic Microwave Oscillators
Kevin Knabe, Ahmer Naweed, Aaron Pung
University of Arizona, Dept. of Physics
Brian Siller, Andrew Mills, Michael Porambo & Benjamin McCall
Principle of Mode Locking
Fiber Laser Part 1.
National Institute for Environmental Studies, Tsukuba, Japan
Raman Spectroscopy A) Introduction IR Raman
Presentation transcript:

Portable, robust optical Frequency standards in hollow optical fiber Mohammad Faheem, Rajesh Thapa, Ahmer Naweed, Greg Johnson, and Kristan Corwin

Motivation Develop high accuracy Portable Wavelength Standards for Telecommunication Industry.

Outline Introduction Broadening Mechanisms and Saturation Spectroscopy Frequency measurement. Previous Work Our Approach Experimental Set-up Results Limitations Future Work

Over View C2H2 Laser 50 Torr ? Frequency measurement Frequency comb

Wavelength Division Multiplex Sources Coupler Fiber Demultiplexer Output Fibers Separation between channel is 1 nm - Channel adjustment in WDM (1525-1565 nm) system. - Calibration of wavelength measurement devices.

Recipe for a Wavelength Standard Atomic or molecular absorption lines - Absolute frequency reference. - Very stable under changing environmental conditions - Good references in the 1500 nm region Good references in 1500 nm region Acetylene (1510-1540 nm) Hydrogen cyanide (1530-1565 nm) Rubidium (1560-1590 nm)

Acetylene ( Also called Ethyne) - Colorless and extremely flammable 50 transition lines, spaced by 60-80 GHz extending from 1515nm-1540 nm C C H H CH n1 Symmetric C- H bond Stretching CC n2 n1+n3 lies in 1.5 mm region CH n3 Anti-symmetric C- H bond Stretching Stretching Vibrations

Important Broadening In IR Spectroscopy Absorption (Beer’s law) z IO I ‘a ‘is the absorption cofficient Absorption sample Doppler Broadening Power Broadening C2H2 at room temp. ~ 500 MHz Laser spectroscopy by Wolfgang Demtroder

Important broadening near IR spectroscopy Pressure broadening and shift Line Broadening C2H2 broadening P(10) ~ 11.6 MHz/Torr Line Shift C2H2 line shift P(10) ~ 0.29 MHz/Torr Transit-Time Broadening Transit time T=d/v 500 KHz for 0.94 mm dia cavity Laser spectroscopy by Wolfgang Demtroder

Saturation Spectroscopy Eliminates Doppler width Requires high Power (Typically 300 mW for acetylene) Dominant Line width Pressure broadening (~11 MHz/Torr) Transit-time broadening (coherence time between laser and molecules) Power Broadening Signal Size Depends linearly on pressure Depends linearly on sample length Laser 90% B.S 10% Pump Beam Probe Beam M2 M1 Cell Det.

Frequency Measurement Frequency = Cycles/second Definition of time Caesium 133 atom Duration of 9 192 631 770 period Of the radiation corresponding to the transition between two hyperfine Level of the ground state of Cs atom. Optical frequency ----- In hundreds of THz Its easy to measure in THz ? Photo Detector ------ In 40-100 GHz What we need to do? Mode Locking Frequency Comb

Time-Frequency Correspondence 2Df tr.t = 1/fr t E(t) Df Fourier transform of periodic signal discrete frequency components. I(f) fo fr f fn = n fr + fo fr Laser repetition rate fo Offset D. J. Jones, et al. Science 288, 635 (2000)

Measurement of fr and fo Repetition Rate fr can be measured with photo-detector in optical path Offset I(f) fo fr f f2n fn 2fn-f2n = 2(nfrep+fo) - (2nfrep+fo) = f0 Octave Spanning - Microstructure fiber - Laser Cavity D. J. Jones, et al. Science 288, 635 (2000)

A. Czajkowski,J. E Bernard,A. A. Madej,R. S A.Czajkowski,J.E Bernard,A.A.Madej,R.S.Winler Self reference frequency comb Unknown signal f fr fo f Unknown signal App.Phys.B79,45-20 (2004)

Solid core microstructure Fiber Fused silica core Cladding Core 1.7 m laser spectrum 100 mW (1 nJ) Spectrum Broadening 20 mW (0.2 nJ) Wavelength (nm) Relative Power (db)

Frequency comb Set-up Fiber in Fiber out Fiber Laser 10 W 1075 nm HNLF SC BS Cr:forsterite Laser DM nonlinear crystal stabilized optical frequency comb Synthesizer f rep Loop Filter Phase Detector

Previous work: K.Nakagawa, M.de Labachelerie, Y.Awaji and Kourogi (J.opt.soc.Am.B/Vol.13,No.12/December1996) Cavity : Long interaction length. High intracavity power (100 mw). Fragile. Cavity and laser locked to resonance independently. Signal Measurement : Two photon Rb (778 nm) transition as a reference. Hydrogen Cyanide(1556 nm, P(27)) as a Intermediate reference.

Previous Work: W.C. Swann and S.L. Gilbert. (NIST) Pressure-induced shift and broadening of 1510–1540-nm acetylene wavelength calibration lines, ” Opt. Soc. Am. B, 17, 1263 (2000). Pressure broadening & shift For P(13) broadening 11.4 MHz/Torr Line shift 0.27 MHz/Torr Effect of Temp negligible effect Used to calibrate Optical Spectrum Analyzers (OSA’s)

Previous Work :A.Czajkowski, A.A.Madej, P.Dube Development and Study of a 1.5 um Optical frequency Standard referenced to p(16) Saturated absorption line in the (V1+v3) overtone band of 13C2H2 Optics Communications 234(2004) 259-268 Saturation signal ~ 1 MHz Measure Power shift 11.4 Hz/mw Pressure Shift 230 Hz/mTorr

Our Approach Develop high accuracy portable wavelength Standards for telecommunication industry. Through existing Technology : - Cavity based references are not Portable. - Transitions in the glass cells can not be further narrowed. Solution : Use molecular absorption inside optical fiber. Advantages: Portable Easy to align Easier to get high intensities over long path.

Experimental Set-up Fiber in Fiber out ultimately: Probe (15 - 300) mW Capacitive manometers Hollow optical fiber Gas Inlet 1 mW To vacuum pump Probe Pump (15 - 300) mW C2H2 molecules ultimately: Fiber in Fiber out

Setup- Optics d2 d1 PD Pump Beam Probe Beam Fiber C2H2Cell PD PBS PD Diode Laser Fringe width~156 MHz Mirror 50/50 d2 d1 Mirror BS PBS Pump Beam Probe Beam 10/90 Fiber EDFA C2H2Cell 30/70 PBS PD ISO Probe Squeezer PBS PD ISO Pump Squeezer λ/2

Capillary Tube Too lossy Only 40% transmission Laser Power loss 2a 1531.31 nm Too lossy Length 18 cm and dia 330 µm Only 40% transmission Doppler Broadened signal observed No saturation signal.

Capillary tube 10 µm PBF gives 50 MHz saturation dip. Satisfy Beer’s law 10 µm PBF gives 50 MHz saturation dip. 300 µm should give 1.73 MHz saturation dip. For saturation dip We need power 865 times

Photonic Bandgap fiber 10 mm loss< 0.02 dB/m No total internal reflection Bragg’s reflection

10-µm Photonic Bandgap fiber

10-µm Photonic Bandgap fiber 1.2 Torr of 12C2H2 at 1531.31 nm Significant signal strength at 10 and 20 mW pump powers!

10-µm Photonic Bandgap fiber We are transit limited or pressure limited ? Line width does not increase significantly with pressure which implies that it is transit time limit.

20-µm Photonic Bandgap fiber 20 mm core, 60 cm length Fiber fills to 2 mTorr in ~ 10 s 20 µm, 83 cm long PBF at 1531.20 nm

20-µm Photonic Bandgap fiber Pressure limited ? Factor of 3 change in pressure gives a factor of 1.2 change in line width Transit limited

10-µm, 20- µm PBF data Comparison Transit Time To reduce Transit time Broadening: increase fiber hole size -or- find a heavier molecule -or- Decrease the velocity of molecule by cooling

Linewidth: (target < 1 MHz) Ultimate limits Signal strength: optimal fiber length for pressure. Noise Interference (probe with stray/reflected pump) laser intensity noise Linewidth: (target < 1 MHz) transit time broadening pressure-broadening To narrow the transition, we must: reduce transit-time broadening reduce the pressure lengthen the fiber

Conclusions - Observed saturated absorption features in photonic bandgap fiber for first time. - Significant absorption fraction observed at low power (< 20 mW), with 23 MHz-wide feature. - Confirmed transit time broadened, 20 mm produce narrower feature than 10 mm fibers

Future Plan Near-term: Longer-term: Make more portable, reduce noise. Build frequency Comb for absolute measurement. Observe dependence of different broadening mechanisms. Observe the shifts in Photonic bandgap fibers. Longer-term: Seal the fiber filled with gas. (Greg Johnson) Narrow the transition Explore larger photonic bandgap fibers Explore other gases.

Thank You

Photonic Bandgap fibers Index guiding Hollow Core guiding

Saturated absorption feature width 10 mm ~ 40 MHz Transit time broadening: Naive estimate t= d/v = ~1/50 MHz Pressure broadening: 11 MHz/Torr * 1.2 Torr = 13.2 MHz

Important Broadening In IR Spectroscopy Doppler Broadening Molecules are in motion when they absorb energy. This causes a change in the frequency of the incoming radiation. Pressure broadening Produce by the shifts of energy levels by interaction of radiating atom with near by particles Transit time Broadening The interaction time of molecules with the radiation field is small with the spontaneous life time of excited levels Power Broadening Molecules absorb energy from intense laser. This causes a energy shift causing broadening.