FAST1® Intraosseous Infusion System

Slides:



Advertisements
Similar presentations
Bougie ET introducer.
Advertisements

EZ-IO By Elspeth Richardson.
Pneumatic Cylinders Chapter 3.
0 - 0.
Sectional Assembly and Installation
The 5 Rights of Intraosseous Vascular Access
Filter Changing Procedures For TEOM Series 1400ab and Model 8500 FDMS (B & C Types)
T-Flex Fitting Instructions 1 Rev
Corning Cabelcon 1. 2 To begin with – we need some tools… Cable cutter Cabelcon Rotary Stripper Mounting tool Compression tool Please read the instructions.
1 One-Man Adult CPR. 2 Remember: CPR can save lives. Do it well. Do it right. And the victim gets a chance at life.
Intraosseous Vascular Access
Introducing Digital Talking-Book Machines Standard player Advanced player.
Intraosseous Vascular Access
Step 1: Digging a Cellar On land, a majority of wells begin with digging a cellar from three to fifteen feet in depth. The purpose of a cellar is to align.
Department of EMS Professions Temple College
Preparing and Administering Medications
BSA 30 Minute Pistol Briefing
Learning Objectives Collect Dried Blood Spots (DBS) for HIV testing
LESSON 16 BLEEDING AND SHOCK.
How to use the Adult BIG device?
NUR 141: SKILL 28-4: CHANGING INFUSION TUBING
Objectives of this presentation… Historical background of intraosseous (I.O.) infusion. The anatomical and physiological principle of I.O. infusion. Familiarization.
PerSys Paediatric Bone Injection Gun B.I.G.. INTRAOSSEOUS ACCESS Penetration of the bone in order to access the intravascular compartment Device inserted.
Common IO Myths BIG Insertion is extremely painful The BIG insertion is very rapid and no more painful than an IV line. In Conscious patients it is recommended.
THE M-9 9MM SERVICE PISTOL
1 EZ-IO in the Pediatric Patient. This presentation is only for Pediatric specific IO site location and placement. For complete IO insertion education,
Urinary – Nephrostomy Catheter Care
Remove driver from needle set Stabilize needle set while disconnecting Hold needle firmly with your fingers. Screw off stylet it’s like a luer lock, unscrew.
Module: Session: Advanced Care Paramedicine Medication Routes 6 4a.
Session IV, Slide #1 TCu 380A Copper-Bearing Intrauterine Devices (IUDs) Session IV: Practicing IUD Insertion and Removal.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
EZ-IO® T.A.L.O.N.TM Tactically Advanced Lifesaving Intraosseous Needle
Assembly of a Syringe. Gather syringe and needle Select a syringe and needle. Syringe size and needle gauge will depend on the provider’s needs. Syringes.
Intraosseous? Think !
Intraosseous Needle Insertion
7- Intravenous (I.V) Infusion
Starting a Peripheral IV Principles of IV Therapy BSN336 Lab.
The 5 Rights of Intraosseous Vascular Access
The 5 Rights of Intraosseous Vascular Access
1 July 2007 P48610 Rev.2 SmartInfuser PainPump ™ P49220, P49224N Operation Instructions.
Pediatric Bone Injection Gun B.I.G.
Gail Vanairsdale Global Clinical Education Manager Enlite Sensor Insertion.
Administration of Vaccine via Intramuscular Route
Review of Current Intraosseous Infusion Devices
Arterial Blood Gases ABG. DEFINATION  An arterial blood gas (ABG) is a blood test that is performed taking blood from an artery, rather than a vein.
INTRAOSSEOUS ACCESS (I.O.) Procedure. Preparation Sterile technique Check needle – align bevels of the needle Support leg on firm surface Palpate landmark.
Session V A, Slide #1 Contraceptive Implants Session V A: Two-Rod Implant Insertion.
CNYEMS 2008 Protocol Additions Phase 1 Medical Director, Daniel Olsson, DO Executive Director, Susie Surprenant Central New York EMS 50 Presidential Plaza.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
AJ5808/5808A INFUSION PUMP QUICK OPERATION GUIDE.
Basic First Aid. basic first aid  Definition: –First Aid is the initial response and assistance to an accident/injury situation. –First Aid commonly.
Intraosseous needle insertion
IO Access Slides Please use selection of slides as appropriate to support practical workshop The workshop is designed as a practical station and slides.
Intraosseous Insertion Gwen Hollaar University of Calgary.
Surgical and Nonsurgical Cricothyrotomy
Epidural Anaesthesia.
Intravenous cannulation
Chapter 47b.
Intraosseous Access with the Sternal EZ-IO ® Needle Set.
P.E.A…Anesthetizing…Shock…Intubation… Two I.V attempts…V.F…O.D…Dyspnea…MVA Dehydration…Cyanosis…infant…C.P.R… ANYTIME ACCESS IS NEEDED IN A HURRY.
Unit 3 Lesson 4 Intravenous (IV) Fluid Administration
Unit 3 Lesson 3 Endotracheal Intubation
Unit 3 Lesson 1 Endotracheal Intubation
Contraceptive Implants Session V A: Two-Rod Implant Insertion
Contraceptive Implants Session IV A: One-Rod Implant Insertion
Contraceptive Implants Session IV B: One-Rod Implant Removal
Contraceptive Implants Session V A: Two-Rod Implant Insertion
Presentation transcript:

FAST1® Intraosseous Infusion System Training Session

Why IO? Peripheral IV is often difficult to obtain Requires an average of 3-12 minutes Failure rate ranges between 10-40% AHA & ILCOR guidelines now recommend IO when IV cannot be obtained

Vascular Access Via IO Infuses fluids into bone marrow Bone marrow drains into vascular system Manubrium especially effective due to close proximity to central circulation

“The FAST1® System is intended for intraosseous infusion as an alternative to IV access, to facilitate emergency resuscitation through the use of drugs and fluids.” (FDA 2008)

Advantages of FAST1® FAST: vascular access within 10 seconds, drugs to the heart in 30 seconds SAFE: automatic depth control prevents over- penetration EFFECTIVE: delivers drugs to heart as quickly as a central line, with shorter access time EFFICIENT: can be inserted during other resuscitation procedures

MORE Advantages of FAST1® MULTI-PURPOSE: anything that can be given via IV can be given via FAST1® VERSATILE: cleared for use in adolescents from 12 years of age and older STERILE: designed for single, sterile use, no cross-contamination SECURE: patented, strain-relief target patch ensures line does not become dislodged

MORE Advantages of FAST1® ADAPTABLE: can be inserted in moving ambulances, helicopters and on stretchers QUICK TO LEARN: skill mastery within minutes EXCELLENT SKILL RETENTION: ability to use FAST1® not dependent upon frequent practice or use

Indications FDA-approved for patients 12 years of age and older (adolescent to adult) Use whenever vascular access is desired Can be left in place up to 24 hours FAST1® field trials included patients ranging from 14 to 94 years old, weighing up to 400 lbs With conscious patients local anesthetic is recommended

Insertion Site Manubrium of sternum, 15 mm below sternal notch, on midline Bone thickness at insertion site:13.30 mm  2.18 Minimum thickness about 35 mm below sternal notch= 9.17 mm  1.78 Risk of over penetration: less than 1 in 1,000,000

FAST1® System Components

FAST1® System Explained Introducer inserts Infusion Tube into manubrium Infusion Tube is mounted on a stylet inside Introducer Stabilizer Points ensure depth control only, they do not penetrate the bone

FAST1® System Explained Relies on operator force only – it is not a gun, not spring-loaded, not battery dependent, nor pneumatic Downward force on Introducer pushes steel Infusion Tube tip through soft tissue, into bone When steel tip is just inside marrow space, Infusion Tube automatically separates from Introducer Ring of Stabilizer Points ensure proper deployment only – they do not enter the bone

FAST1® System Explained Depth control mechanism prevents over-penetration Infusion Tube flexes with movement of patient’s skin preventing dislodgements, unlike other IO products which use rigid infusion needles Patented strain-relief mechanism and plastic dome provide additional protection

Insertion Procedure Expose sternum Swab insertion site Remove backing labeled #1 Put index finger in sternal notch

Insertion Procedure Place Target Patch notch next to index finger Press down firmly over top of Patch Remove backing labeled #2, press Patch down firmly

Insertion Procedure CRITICAL: For safe and effective use of the FAST1® verify Target Patch placement at sternal notch, in midline with Target Zone over manubrium

Insertion Procedure Place orange Sharps Plug on flat surface with foam facing up Stand/kneel at head of patient, if possible Twist and remove cap from Introducer Place Stabilizer Points in target zone PERPENDICULAR TO MANUBRIUM

Insertion Procedure Push firmly with increasing force until Introducer releases Pull straight back to remove Introducer Push Introducer Stabilizer Points into Sharps Plug and place in sharps container

Insertion Procedure The completed assembly with Dome, Target Patch, Infusion Tube (blue Luer) attached to the proximal end of the Connector Tube (blue cap) and IV line attached to its distal end

Flow Rates FAST1® provides exceptional delivery of drugs & fluids via: Gravity= 30-80 ml/min Pressure infuser= 125 ml/min Syringe= 250 ml/min

Removal - Original FAST1® Remove Protector Dome from Target Patch Disconnect white-tipped Infusion Tube Do not pull on Infusion Tube to remove it! 3. Take Removal Tool from package and remove protective sheath

Removal - Original FAST1® Keep Infusion Tube perpendicular to manubrium, insert Removal Tool Advance Removal Tool until you hear or feel metal on metal SLOWLY & GENTLY turn Removal Tool until it stops Place fingers under flange of tool and pull perpendicular to manubrium to remove Infusion Tube

Removal - Original FAST1® Remove Target Patch Apply pressure and dress site Dispose of contaminated Remover Tool and Infusion Tube appropriately

Removal - New Model (Blue) Remove Protector Dome Disconnect Infusion Tube Grip blue-tipped Infusion Tube at point of insertion Pull blue-tipped Infusion Tube perpendicular to manubrium Remove Target Patch Apply pressure, dress site Dispose of appropriately

Precautions Safe for use in patients 12 years and older (adolescent to adult) Trauma, infection, burns, or fracture of manubrium may preclude use Safety with very severe osteoporosis has not been proven Use in patients with recent sternotomy may prove less effective Not for use in patients with abnormal sternal anatomy

Troubleshooting Introducer does not release: Pull Introducer back, if Infusion Tube remains verify placement by aspirating marrow, proceed with use If marrow cannot be withdrawn, remove tube and insert second FAST1® Introducer releases but Infusion Tube is not secured in patient: Use new FAST1®

Troubleshooting Force is applied but Introducer does not release: Without pulling back, ensure Introducer is perpendicular to manubrium and force is being applied directly along this line Leakage At Insertion Site: If excessive, use alternative method of vascular access