Overview of PowerCube Units and ANSI frames

Slides:



Advertisements
Similar presentations
Control Circuit Protection Supplementary Protectors vs
Advertisements

Medium-Voltage Switchgear - Then and Now -
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
AC-SSC-1 Installation and operation manual
M iniature circuit breakers to UL 489
SHS2 Gas insulated switch–disconnector / isolator
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
Sales Training Outline 2006 Klaus Tum Product Manager Motor Disconnect Switches 35 Royal Road Flemington, NJ
1 GE Digital Energy Instrument Transformers, Inc. Test Switches & Plugs Type FT Type RT Type PK-2.
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
GCB Service Earthing Switch Retrofit Kit for HGC-3 & HEC 3..6 ABB High Current Systems Services © ABB Group April 15, 2017 | Slide 1.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
Smaller Simpler Better
FIPTMV Medium Voltage Technology
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
ABB - 1- ABB ABB Load Interrupter Switchgear. ABB - 2 ABB Contents Introduction to Load Interrupter Switchgear What, Where, Why ABB Technical Offering.
VHA PANEL WITH HPA12 CIRCUIT BREAKER
SF6 load-break switch-disconnector
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
Breaker Basics Welcome to this general overview of ABB.
© ABB Group Aug-15 Medium Voltage Hard Bus Retro-fill ABB MV Service.
MaxSG - Low Voltage Switchgear
Multi-function apparatus for secondary distribution
Dry type transformers Zaragoza Accessories and options
Medium Voltage Switchgear
Masterpact LV power air circuit breakers and switch disconnectors
UniGear ZVC Standard Product
MNS Sprint - A Market Driven Solution
All rights reserved MV SWITCHGEAR.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. CENTERLINE 2100 Motor Control Center - SecureConnect™ September 1, 2011.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
PowerIT Air Insulated Cubicle Uniswitch
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
Sales Training Outline 2006 Klaus Tum Product Manager PIN & Sleeve Devices 35 Royal Road Flemington, NJ
Switchgear for Primary Distribution
FLATPACK Rev.5 September 2002 Updated versions may be available.
Bus Duct is a type of fixed electrical conductor, available with a stranded metallic housing that is manufactured by Brilltech in fixed lengths and.
S A Griffiths CM42 June 2015 Electrical & Control.
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Low Voltage Systems MNS iS with MSpeed Technical Introduction
SUB-STATIONS.
3AH5 Vacuum Circuit-Breaker For Standard Applications
SBU Digital Infrastructures NEW LINKEO – Freestanding cabinets
DESCRIPTION AND GUIDE TO OPERATIONS
GROUND-FAULT GROUND-CHECK MONITOR
Name, department/event, date
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Practice Code Look Up Two Minute Drill #7
Associated Hazards and Safety Practices
Overview Key diagram of 220 KV Sub station, Ablowal Cables
SION Vacuum Circuit-Breaker For Standard Applications
Engineering Project Cable Management.
KONČAR – Switchgear Inc.
Low Voltage Products division
ABB SACE Emax 2 ANSI C37 / UL1066 Concept Global Product Management
EET 323 – Electrical System Design Lecture 11: Panel-boards and Switch-boards Instructor: Radian Belu, PhD.
All rights reserved Gas-insulated Switchgear (GIS)
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
Its strengths, your benefits
Presentation transcript:

Overview of PowerCube Units and ANSI frames Davide Bani, Product Management – June 2015 ABB Cassettes Overview of PowerCube Units and ANSI frames

ABB Fix units PowerCube family and ANSI units Cassettes are available in different configurations all IEC units are available, on request, with earthing switch: Enclosures type PB/E – PB/RE Mounting frame type PB/F-PB1/FL Enclosure type PB/N Modules type PB/M – PB/RM PowerCube PB6 – 36kV PowerCube type Powerbloc 36kV..40.5kV ANSI units PowerCube units are designed to be used as main component of the switchgear providing a consistent base to develop a wide range of switchgear typical units according to latest IEC standard (62271-200) © ABB Group September 17, 2018 | Slide 2

PowerCube type PB: Units up to 24kV - Summary PowerCube type PB/F: Frame up to 2000A 31,5kA Circuit breaker / Contactor interface Pre-assembled and pre-tested safety interlocks Earthing switch on request High OEM content to design the panel PowerCube type PB/E: Enclosure Complete cell: PB/F + Arc proof door and top low auxiliary connections Wider range than PB/F (up to 4000A 50kA) Medium OEM content to design the panel PowerCube type PB/M: Module Complete module: Apparatus and Cable access or voltage transformer compartment VT compartment on request More complete ABB proposal to design the panel © ABB Group September 17, 2018 | Slide 3

PowerCube type PB/M Module structure Circuit-breaker / Contactors / Service truck Natural cooling ratings 12÷17kV ..3150A ..50kA 24kV ..2000A 31,5kA Forced ventilation ratings 12÷17kV ..4000A ..50kA 24kV ..2500A 31,5kA With apparatus compartment PowerCube type PB/M Without apparatus compartment (risers) PowerCube type PB/RM Terminals Earthing switch (on request) Feeder compartment Metallic shutters VT compartment (on request, not available on all units) Fan (when applicable) © ABB Group September 17, 2018 | Slide 4

PowerCube type PB/E Enclosure structure Natural cooling ratings 12÷17kV ..3150A ..50kA 24kV ..2000A 31,5kA Forced ventilation ratings 12÷17kV ..4000A ..50kA 24kV ..2500A 31,5kA With apparatus compartment PowerCube type PB/E Without apparatus compartment (risers) PowerCube type PB/RE Terminals Metallic shutters Earthing switch (on request ) Circuit-breaker / Contactors / Service truck Fan (when applicable) © ABB Group September 17, 2018 | Slide 5

PowerCube type PB/F – PB/FL Mounting frame structure PowerCube PB/F: Natural cooling ratings 12÷17kV ..2000A ..31,5kA 24kV ..1250A 31,5kA Forced ventilation not applicable Riser units not available PowerCube PB/FL Eathing switch not available Suitable for VM1/A/P according ANSI std Metallic shutters Terminals Earthing switch (on request ) © ABB Group September 17, 2018 | Slide 6

Units up to 24kV: Suitable apparatus PowerCube type PB Units up to 24kV: Suitable apparatus VD4 VM1 V-Contact VSC/P HD4 HD4 service trucks © ABB Group September 17, 2018 | Slide 7 Vmax

PowerCube type PB Enclosures type PB/N for MCC panels Compact MCC cassette: Up to 12kV 400mm wide panels 390A rated current with 2 BS type fuses in parallel at 7,2kV Suitable for Internal arc proof panels short circuit level according to installed fuses Apparatus: V-Contact VSC/PN © ABB Group September 17, 2018 | Slide 8

Enclosures type PB/N for MCC panels PowerCube type PB Enclosures type PB/N for MCC panels The apparatus can assume 3 different positions: Disconnected position Test/Isolated position Service position Earthing automatically operates between test and disconnected position © ABB Group September 17, 2018 | Slide 9

Enclosures type PB/N for MCC panels PowerCube type PB Enclosures type PB/N for MCC panels Position contacts: Extract-isolated/test-connected Metallic shutter Automatic earthing switch Main teminals (flat copper bar) Area for internal arc gas exit © ABB Group Month DD, Year Data and images are not binding. We reserve the right to make modifications without notice during development of the product.

Enclosures type PB/N for MCC panels PowerCube type PB Enclosures type PB/N for MCC panels Door interlock Rack-in/out operating slot Earthing switch and auxiliary connector inspection window Sensor not to rack in with open door On the panel On the contactor Plug and socket: Cord with socket on the panel Fix plug on the contactor © ABB Group Data and images are not binding. We reserve the right to make modifications without notice during development of the product. Month DD, Year

PowerCube type PB Module type PB6 up to 36kV Module up to 36kV: 1000mm wide panels Up to 2500A rated current Suitable for Internal arc proof panels Short circuit level up to 31,5kA Earthing switch on request Branches on request Related apparatus: VD4 HD4 VT truck © ABB Group September 17, 2018 | Slide 12

PowerCube type PB Module type PB6 up to 36kV Natural cooling ratings 36kV ..2000A 31,5kA Forced ventilation ratings 36kV ..2500A 31,5kA With apparatus compartment PowerCube type PB6 Without apparatus compartment (risers) PowerCube type PR6 With terminals With branches © ABB Group September 17, 2018 | Slide 13

Base of TCA – Technical Cooperation Agreement PowerCube type PB Base of TCA – Technical Cooperation Agreement TCA is a contract that allow the customer to receive an ABB panel knowledge to reduce time to market for an IEC fully certifiable panel ABB will provide to customer dedicated PowerCube connections to manufacture panel busbar system (differentiation from other customers) The customer manufacture the complete panel ABB provide to customer PowerCube PB/M and apparatus © ABB Group Month DD, Year

PowerCube type Powerbloc Module type Powerbloc up to 40,5kV Module up to 40,5kV: 1200mm wide panels Up to 2500A rated current Suitable for Internal arc proof panels Short circuit level up to 31,5kA Earthing switch on request Related apparatus: VT truck HD4 VD4 © ABB Group September 17, 2018 | Slide 15

PowerCube type Powerbloc Module type Powerbloc up to 40,5kV With terminals Natural cooling ratings 40,5kV ..2500A 31,5kA Forced ventilation ratings 40,5kV ..3150A 31,5kA Available with: Apparatus compartment VT truck compartment Riser Earthing switch on request © ABB Group September 17, 2018 | Slide 16

ANSI fix part for ANSI breaker Cassette and L-Frame Units up to 27kV: 914.4mm (36in) wide panels Up to 3000A rated current Manufactured in ABB US – Lake Mary Related apparatus: ADVAC AMVAC © ABB Group September 17, 2018 | Slide 17

PowerCube type Powerbloc ANSI kits Provides flexibility for an OEM to utilize a minimum number of components and maximize the value added. Breaker, PT, CPT, and Drawout Fuse Kits include the unassembled minimum components necessary Breaker compartment kit offerings include: 5-15 kV / 50 kA 27 kV / 25 kA 5-15 kV / 63 kA Door kit available with appropriate hardware and labels UL recognition provided as a standard for all compartment kits 15 kV Kit 27 kV kit 63 kA Kit CPT Kit © ABB Group September 17, 2018 | Slide 18

ANSI fix part for ANSI breaker L-Frames ABB’s L-Frames are an assembled breaker kit with the inclusion of a floor pan and back panel Breaker L-Frame offerings include: 5-15 kV / 50 kA 27 kV / 25 kA 5-15 kV / 63 kA Door kit available with appropriate hardware and labels UL recognition provided as a standard for all L-frames L-Frame w/ Metal Shutters L-Frame w/ Lexan Shutters and Circuit Breaker © ABB Group September 17, 2018 | Slide 19

ANSI fix part for ANSI breaker Cassette Breaker Compartments 15kV: 1200A, 2000A, 3000A breaker compartments, 50kA 27kV: 1200A, 2000A breaker compartments, 25kA Standard metal shutters and dual secondary disconnect PT, CPT, and Fuse Compartments 19” PT compartments 38” CPT/fuse compartment Rack In/Rack Out capabilities Instrument Compartments Dedicated compartment design isolates control equipment and circuits from high voltage areas Available in 19”, 38”, or 57” height with 22” depth Supplied with grommets for cross panel wiring Supplied with cutouts for wiring to upper and lower primary compartments in the same vertical section Cassette compartments © ABB Group September 17, 2018 | Slide 20