Team Super 8: Sat Morpheus Launch Readiness Review Jonathan Sobol, Evan Graser, Scott Wurst, Daniel DeWolf, Dan Nowicki, MattJoo Hong, Anthony Lima, Jorge Cervantes November 27th 2012
Mission Overview Morpheus will continuously measure Ozone concentration UV-B radiation To determine the correlation between these as a function of altitude, if any.
Design Overview Design Specs: 16 cm sided cube UV-B diode and ozone sensors at topmost four corners Other hardware has been placed along internal walls Heater has been separated into 3 components to distribute heat.
Design Overview
Test Results: Functional Standard required sensors (HOBO) External temperature sensor Ozone sensors UV-B photodiode Camera
Test Results
Test Results
Test Results
Camera Test
Test Results: Structural Drop Test Whip Test Temperature Test
Predicted Results
Predicted Results
Biggest Worries/Concerns Arduino not functioning properly Temperature too extreme for external components
Compliance Matrix Description 0.1 0.2 0.3 0.4 0.5 Require-ment # Description Measure concentrations of ozone and UV-B radiation as a function of altitude 0.1 Reach an altitude of 30 km 0.2 Maintain an internal temperature above -10 ° C 0.3 Abide by a weight and monetary budget of 1.125 kg and $250, respectively 0.4 Maintain safe working condition and ensure the general safety of the team members through out the project 0.5 Morpheus must be in pre-flight conditions with in 24 hours after it is retrieved