IEC enabled MV PrimSwgr

Slides:



Advertisements
Similar presentations
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
Advertisements

Megger - Substation overview product groups, 2600 products.
IEC Substation Configuration Language and Its Impact on the Engineering of Distribution Substation Systems Notes Dr. Alexander Apostolov.
© ABB Group June 10, 2015 | Slide 1 1MRS A self healing power system for the accurate fault location and zone concept T&D Smart Grids Europe 2012.
Communication Networks and Systems In Substations
© ABB - Page 1 Long lifetime guaranteed for IEC Designed for the future... SCL ACSI APP COM.
Network Topologies.
Introduction to BIM BIM Curriculum 01.
Motor Control Center MNS iS with Condition Monitoring
Network Design Essentials. Guide to Networking Essentials, Fifth Edition2 Contents 1. Examining the Basics of a Network Layout 2. Understanding Standard.
Network Design Essentials
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
Intro to Network Design
1 / Name / Date IDA Interface for Distributed Automation The journey toward Distributed Intelligence.
Internet 0 for Industrial Applications Fred Cohn 13-Dec-07.
PowerIT Air Insulated Cubicle Uniswitch
New product introduction:
S V.MOUNICA 09551A0294.  To increase the distribution rate of present electric supply which is 70% to 100%.  Improving the supply to house holds without.
Survey of Smart Grid concepts and demonstrations Smart substation Ari Nikander.
Overview Presentation MKT-DSRV-P- 001E. Product Overview Network based video transmission product with on-board digital recording Allows analogue fixed/PTZ.
How Sage ERP X3 Systems Can Benefit Businesses.  Sage X3 is an affordable and flexible ERP solution designed to help mid-sized companies manage business.
BASIC CONCEPTS OF NETWORK. INDEX  Definition & applications of computer network  Components of computer network  Network benefits  Disadvantages of.
McGraw-Hill©The McGraw-Hill Companies, Inc., 2000 Muhammad Waseem Iqbal Lecture # 20 Data Communication.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
The New Generation of CAD Tools
WIRELESS FIRE DETECTION
LAN, WAN, and Network Topologies
Network Topology and LAN Technologies
Business System Development
Introduction to Electric Power System and A. C. Supply
Chapter 19: Network Management
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
COSEC ARC IP based Access Control Panel.
ControlEdge™ PLC. System Integration. Design Flexibility. Connectivity
Computer Network Collection of computers and devices connected by communications channels that facilitates communications among users and allows users.
Chapter 2: Network Design Essentials
CS408/533 Computer Networks Text: William Stallings Data and Computer Communications, 6th edition Chapter 1 - Introduction.
PLM, Document and Workflow Management
Smart Ethernet I/O P2P and GCL Introduction
NETWORK TOPOLOGIES There are three basic configurations used to connect computers they are the Bus Ring Star.
CHAPTER 4 TOP LEVEL VIEW OF COMPUTER FUNCTION AND INTERCONNECTION
Unit 5 Systems Integration and Interoperability
Introduction to Networking
Introduction to Networks
IOS Network Model 2nd semester
SALES: HOW TO USE THIS PRESENTATION
ETS Inside Product Launch
IEC enabled UniGear Tenders
Outline Introduction Switchgear Modeling in IEC 61850
Programmable Logic Controllers (PLCs) An Overview.
Protocols and the TCP/IP Suite
Peter Erning, PSP-T11, Power Gen 2010
GPRS GPRS stands for General Packet Radio System. GPRS provides packet radio access for mobile Global System for Mobile Communications (GSM) and time-division.
Across the entire value chain
An Introduction to Computer Networking
Computer networking In this section of notes you will learn the rudiments of networking, the components of a network and how to secure a network.
Wojciech Szela, Edward Gdowik – PECO
ABB SACE Emax 2 ANSI C37 / UL1066 Concept Global Product Management
Friday, December 28, 2018 ABB SACE Emax 2 Concept
Unit# 5: Internet and Worldwide Web
Cloud Consulting Services and Solutions
REMOTE POWER MONITORING OF MARINE SITES
Introduction and Overview
Protocols and the TCP/IP Suite
Its strengths, your benefits
Its strengths, your benefits
William Stallings Computer Organization and Architecture
Presentation transcript:

IEC 61850 enabled MV PrimSwgr 0 1 0 0 1 1 0 0 1 0 0 1 1 0 1 0 1 0 1 0 0 1 0 1 0 1 1 1 1 0 0 0 1 0 1 0 1 0 1 0 0 1 1 0 0 0 1 1 1 0 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 1 1 1 0 0 0 1 1 0 1 0 1 0 0 1 0 1 0 1 0 1 0 1 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 0 1 0 1 0 1 0 May 2013 IEC 61850 enabled MV PrimSwgr General presentation

IEC 61850 enabled MV Primary Switchgear What does influence effective communication? Language Dialect Different Language Slang Translation Accent The communication is process whereby information is transferred from a sender to receiver. The receiver could be an individual person, a group of persons or even an audience. What does influence effective communication? First of all it is language. Different language There are a lot of nations around the globe speaking completely different languages about the same topics . Dialects Individual regions in each country could have common language but different dialects . Slang Moreover in some towns and cities slang is used not to be all so easy. Translation Even thought some of us can speak in different languages, we can make fault interpretation in our head. The simplest way of successful communication is to used the same language without dialects, slang!!!

IEC 61850 enabled MV Primary Switchgear What does influence effective communication? Way of transmitting Bottlenecks Homogenous environment What else can affect communication? The same language is just one condition of effective communication, the second one is way of transmitting. Just imagine wall among us! Our speech will be muted and the person behind the wall can hear only fragments of our speech. To avoid loosing some information the homogenous environment should be used. Bottleneck? Of course, data can be delayed due to it. And there are other examples.

IEC 61850 enabled MV Primary Switchgear Communication in substation Way of transmitting Different languages Device A Reliability of system Interpreter, Converter ? System response Device B ? Engineering Device C Let‘s talk about communication in substation, there is jungle of languages and different ways of transmission. There are a lot of different languages used to communicate between devices on different level. Some of them are typical for industry, utility etc. Some of them are open to other vendor, some of them are vendor specific. Moreover there is no or minimum languages among devices on the same level. If devices speak in different languages, interpreter has to be used, but it brings in majority cases losing of some information, more engineering, faults There are a lot of way of transmitting linked with language. Both used language and way of transmitting influence reliability of system, system response, engineering, amount of data. Amount of data

IEC 61850 enabled MV Primary Switchgear More simlified life = IEC 61850 standard One World One Technology One Standard IEC 61850 standard One global language for all Widespread, Extra fast, Reliable Way of transmission Communications networks and systems for power utility automation To make your life more simplified, choose IEC 61850 standard and exploit its benefits. The standard offers on the one hand one global language for all without exception, it is applicable to both ANSI and IEC world and has been developed in co-operatrion between vendors (ABB, Schneider, Siemens, GE, Toshiba, ...) together with major utilities (Vattenfall, RWE, EDF, Iberdrola, ENEL, ...) On the other hand it offers widespread, extra fast and reliable way of transmission – Ethernet. In technical words IEC 61850 standard represents Architecture for power utility automation, if you want, it is Esperanto for Communication in substation.

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / The Main ideas Same language The same language for all, dialects are not allowed Descriptive, unique words Standardized Configuration language Devices and systems from different vendor (ABB, …) talk to each other in the same language without dialects, slangs, … so anybody understands. It is easy to integrate devices from different vendors into projects. Words are self descriptive, there is no need of additional explanation. The meaning of words is unique, not possible misunderstanding. Standardized Configuration languages is used for efficient engineering and information exchange e.g. between devices and system configuration tools from different vendors.

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / The Main ideas Free configuration Free allocation of functionalities Different application philosophies Centralized and / or decentralized solutions IEC 61850 standard allows free allocation of functionalities to devices on all levels . This allows to create different application philosophies (more centralized and/or decentralized solutions). Free configuration supports tailored design of Substation Automation System architecture to meet specific needs and operation.

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / The Main ideas Long term stability Communication = Language (IEC 61850) + Way of transmitting (Ethernet) Language and Way are spllited Gives the benefit of the evolving communication technologies advantages The third key idea of the standard is independency of language from advancing way of transmission. Language is represented by IEC 61850 and Ethernet , which has been with us for many years and is the basis for vast majority of office networks around the world , was selected as way of transmitting. The separation of two essential parts of communication gives us the benefits of the evolving communication technologies. Analogy: First half 19. Century - optical semaphore telegraph system followed by Electrical telegraph – electrical pulses Second half 19. Century - Telephone – Transmit and receive sound over wire lines Second half of 20 century – Mobile phone – transmit and receive sound without wires.

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / Benefits Scalability Easy modification of functionalities Easy extension of substation Save time Engineering, configuration work, commissioning and startup Connectivity Quick and easy connection to the SCADA Improved diagnostic Constant supervision of communication link between Intelligent Electronic Devices (IEDs) Performance High bandwidth, more information about devices Asset management More information about devices in primary and secondary technology Scalability Adding devices and application into existing IEC 61850 system can be done with only minimal impact. Used network (Ethernet) enables easy extension of substation and easy integration by utilizing the same networking technology that is being used across utility or industrial enterprise. (Shorter Down time) Save time Time for configuration and commission devices is reduced, because IEC 61850 devices don’t required as much manual configuration as legacy devices. Client applications retrieve signal list directly from device or import it via standardized configuration file. Most manual configuration is eliminated thereby errors are drastically reduced. (Faster commissioning) Connectivity Quick and easy connection to the upper level system by the help of file import with standardized configuration language. e.g. RTUs, MicroSCADA, 800xA and easy engineering (Easy access to needed data) Improved diagnostic The communication link between IEDs is constantly supervised, link status is known before use, it isn’t valid for conventional wiring (faster and earlier elimination of errors) Performance High bandwidth providing higher level of functionality (e.g. priority for GOOSE and Sampled Measured Values) , shorter response time E.g. Distributed ARC protection is faster and more safe – in general Asset management More information about devices in primary and secondary technology are available where data is named using descriptive string to describe the data defined by IEC 61850 standard and provided in power system context that enables to immediately identify the meaning of data.

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / Benefits Remote Engineering and troubleshooting Remote connection to IEDs via Ethernet interface Remote IED configuration or setting changes Via secured remote connection to substation Remote monitoring and testing of signals which is not possible with wires Substation based disturbance records handling

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / Engineering IED Configuration Tool System Configuration Tool Client (e.g.control centre) Standardized configuration language

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / Engineering process Benefits Configuration Data reuse and exchange via standardized configuration language Save time Export / Import of standardized configuration file Client applications (control centre, communication gateway, …) retrieve signal transfer list automatically via standardized configuration file Most manual operation is eliminated Reduction of errors Standardized, unique and Self-descriptive data Top-Down and Bottom-Up engineering approach support

IEC 61850 enabled MV Primary Switchgear IEC 61850 Standard / Station bus 1st device, will you send me information about ..? It’s Horizontal GOOSE communication It’s vertical communication I can hear you and help you I have problem to perform operation Yes, I will IEC 61850 standard specifies Station communication. It distinguish vertical and horizontal one. Vertical communication is non-time critical communication mainly among Intelligent Electronic Devices and Substation Automation systems. Horizontal GOOSE communication is real time and time critical communication between Intelligent Electronic Devices. It has priority to vertical communication. It is used to transmit e.g. interlocking, blocking , … signals between panels in substation.

IEC 61850 enabled MV Primary Switchgear Generally Brings the benefits of IEC 61850 standard to your substation Move towards SmartGrids solutions

IEC 61850 enabled MV Primary Switchgear Usage Fast horizontal GOOSE communication between panels / IEDs True IEC 61850 support with Relion® IEDs

IEC 61850 enabled MV Primary Switchgear Conventional vs. GOOSE approach Conventional approach Wiring between devices must be done individually per signal … Horizontal GOOSE communication Number of interconnections is equal to number of devices Communication Network (Ethernet) Conventional approach Wiring between the IEDs has to be done individually for each signal, from bay device to bay device. An output signal can be shared, but inputs have to be used individually. GOOSE Where Horizontal GOOSE communication is implemented, Low Voltage Compartment production is independent of the logic, automatic , … between panels (interlocking, blocking etc.). All Intelligent Electronic Devices (IEDs) are connected via a single connection to the network and the Data is shared across all IEDs. This approach means less wires, less terminals, less testing, less errors, … comparing previous mentioned approach. …

IEC 61850 enabled MV Primary Switchgear GOOSE approach Benefits Faster performance Horizontal GOOSE communication is faster than hardwired one Higher error detection Interruption of communication link is detected within configurable setting Preconfigured fail-safe operation in case of failure Tested and proved by KEMA Performance tests according to IEC 62271-3 All IEC61850 components used in MV Primary switchgear are certified by KEMA: Intelligent electronic Devices, Ethernet switches, Switchgear – Inspection report Comparison of the hardwired and GOOSE performance of UniGear and ZX switchgear panels with Relion® Protection and Control IEDs based on IEC 62271-3 performed by KEMA proved that: GOOSE performance is faster than the overall hardwired performance GOOSE reliability and interruption of the Ethernet link are detected within a configurable setting Performance Faster signal transfer , time saving has real meaning in terms of substation Improved diagnostic The safety of the system is enhanced by mean of constantly supervised connection, Lost wire contact isn’t immediately noticed, but with IEC 61850 it is and IED can perform preconfigured fail-save action.

IEC 61850 enabled MV Primary Switchgear GOOSE approach Benefits Interconnections between panels (conventional vs. GOOSE approach) Simplicity All devices are connected via single attachment to the network Higher level of standardization Standardized mechanical and electrical connections and links Logics can be defined after construction phase Less I/O HW in IEDs The IEC 61850 standard affects not only the design of Intelligent Electronic Devices , monitoring and control systems, but also the design of the substation secondary circuit. Horizontal GOOSE communication between IEDs in a substation using the substation's local area network will bring new added value to customers in all aspects compared to the traditional method of signal transfer. First of all it is simplicity, all IEDs are connected via single attachment to network. The standardization of the panels will shorten the workflow process in factory since the logics can be defined after the construction phase and fewer documents are needed before starting the construction phase. It will be easier to build a standardized panel since the logic is on the network and the number of cables to be wired is minimized.

IEC 61850 enabled MV Primary Switchgear GOOSE approach Benefits Flexibility Simple or complex automation schemes with no increase of wiring costs, programming is independent of wiring Last minute change possible No additional HW costs Scalability Switchgears, SCADA … Connectivity To upper level system, to Smart Grids Save time Manufacturing, erection, start-up, maintenance Lower cost to use Up-to-date and Future-proof technology Long-term validity, right investments Flexibility Simple or complex schemes are possible with no increase of wiring costs, because Data are shared across all IEDs connected into IEC 61850-8-1 network via single attachment. Programming is independent of wiring. Late On-site or Last-minute (e.g. during FAT) fast signal logic addition or modification is possible without increasing wires and having spare IO from IEDs – there are no additional HW cost. Substation down time in case of logic changes implementation or extension is shorter Scalability Adding devices and application into existing IEC 61850 system can be done with only minimal impact. Even system used typically in industrial segment 800xA can seamless interface with IEC61850 network. COM600 – GOOSE support Connectivity The switchgear is ready for connection to upper level system or Smart Grids Save time Time for configuration and commission devices is reduced, because IEC 61850 devices don’t required as much manual configuration as legacy devices. Less problems with On-Time delivery Up-to-date and Future-proof technology Independency from the fast advancing communication technology gives the benefits of their evolution. It is implemented communication technology (Ethernet) where the most money is put in and where further development continues (e.g. Ethernet speed raised to 1000Gbit/s)

IEC 61850 enabled MV Primary Switchgear IED connectivity into IEC 61850-8-1 Station bus Converter is needed Supported communication Vertical Relion® protection and control True, native support for IEC 61850 Supported communication Vertical Horizontal GOOSE Dedicated web page www.abb.com/relion ABB distribution Automation‘s complete portfolio of IEDs can be seamlessly connected into IEC 61850-8-1 communication network. Every ABB IED, from the single SPACOM, IMPRS, DPU family up to very complete and fully configurable 500 series are able to communicate with IEC 61850 systems via converter. The Relion® product family provides true, native support for IEC 61850 standard. There is no converter, not even inside, all available functionality using IEC 61850. The compliance of Relion® IEDs with the IEC 61850 standard was tested by KEMA. The implementation of the IEC 61850 substation communication standard in Relion IEDs supports both vertical and horizontal GOOSE communication.

IEC 61850 standard isn’t there to make your life more complicated, but ….